Optical sensor systems for bioprocess monitoring
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These sensors are non‐invasive, non‐destructive, and allow the detection of several molecules simultaneously.”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Marose et al., 1999
In the citing paper
“Also, as non‐invasive techniques, spectroscopic sensors do not interfere with the biological material, allowing to monitor in vivo cells and obtain information on their intracellular state, in addition to information on extracellular media (Marose et al., 1999; Ulber et al., 2003; Hantelmann et al., 2006; Glindkamp et al., 2009).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Marose et al., 1999
In the citing paper
“However, some of the bottlenecks need improvement: the inability to distinguish viable from non‐viable cells, the narrow cell concentration range where it can be applied, and the sensitivity to different cell morphologies.”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Marose et al., 1999
In the citing paper
“The low absorption coefficients enable a higher penetration depth, allowing the use of this technique in solids or turbid liquids, such as culture broths (Marose et al., 1999; Ulber et al., 2003; Glindkamp et al., 2009; Henriques et al., 2010).”
From Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry (2022) · cites this paper as Marose et al., 1999
Citations
Cites
Duysens, L. N. M., & Amesz, J. (1957) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(57)90141-5 · Cited by 365
Oxygen-Sensitive Luminescent Materials Based on Silicone-Soluble Ruthenium Diimine Complexes
Klimant, I., & Wolfbeis, O. S. (1995) · Analytical Chemistry · doi:10.1021/ac00114a010 · Cited by 314
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Self-citationNeural-network contributions in biotechnology
Montague, G., & Morris, J. (1994) · Trends in Biotechnology · doi:10.1016/0167-7799(94)90048-5 · Cited by 182
Characterization of acetone-washed yeast biomass functional groups involved in lead biosorption
Ashkenazy, R., Gottlieb, L., & Yannai, S. (1997) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19970705)55:1<155::aid-bit16>3.0.co;2-l · Cited by 178
On-line and in situ monitoring of biomass in submerged cultivations
Olsson, L., & Nielsen, J. (1997) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01136-0 · Cited by 159
Cavinato, A. G., Mayes, D. M., Ge, Z., & Callis, J. B. (1990) · Analytical Chemistry · doi:10.1021/ac00217a015 · Cited by 158
Real-time detection and quantification of DNA hybridization by an optical biosensor
Watts, H. J., Yeung, D., & Parkes, H. (1995) · Analytical Chemistry · doi:10.1021/ac00119a013 · Cited by 131
Real-time biomass-concentration monitoring in animal-cell cultures
Konstantinov, K., Chuppa, S. L., Sajan, E., Tsai, Y.-S., Yoon, S., & Golini, F. (1994) · Trends in biotechnology · doi:10.1016/0167-7799(94)90049-3 · Cited by 115
Optical triple sensor for measuring pH, oxygen and carbon dioxide
Weigl, B. H., Holobar, A., Trettnak, W., Klimant, I., Kraus, H., O’Leary, P., & Wolfbeis, O. S. (1994) · Journal of Biotechnology · doi:10.1016/0168-1656(94)90175-9 · Cited by 95
Cited by
Real-time bioprocess monitoring
Vojinović, V., Cabral, J. M. S., & Fonseca, L. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.07.059 · Cited by 221
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175
Biomass measurement online: the performance of in situ measurements and software sensors
Kiviharju, K., Salonen, K., Moilanen, U., & Eerikäinen, T. (2008) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-008-0346-5 · Cited by 173
Sensors Based on Bio and Biomimetic Receptors in Medical Diagnostic, Environment, and Food Analysis
Kozitsina, A., Svalova, T., Malysheva, N., Okhokhonin, A., Vidrevich, M., & Brainina, K. (2018) · Biosensors · doi:10.3390/bios8020035 · Cited by 161
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
Improvement of bioprocess monitoring: development of novel concepts
Clementschitsch, F., & Bayer, K. (2006) · Microbial Cell Factories · doi:10.1186/1475-2859-5-19 · Cited by 129
On‐line biomass monitoring of CHO perfusion culture with scanning dielectric spectroscopy
Cannizzaro, C., Gügerli, R., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10809 · Cited by 130
In situ sensor techniques in modern bioprocess monitoring
Beutel, S., & Henkel, S. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3470-5 · Cited by 121
Bioreactor control systems in the biopharmaceutical industry: a critical perspective
Mitra, S., & Murthy, G. S. (2021) · Systems Microbiology and Biomanufacturing · doi:10.1007/s43393-021-00048-6 · Cited by 136
Rapid monitoring of recombinant protein products: a comparison of current technologies
Baker, K. N., Rendall, M. H., Patel, A. I., Boyd, P., Hoare, M., Freedman, R. B., & James, D. C. (2002) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01914-x · Cited by 113
On-line soft sensing in upstream bioprocessing
Randek, J., & Mandenius, C.-F. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1312271 · Cited by 86
Methods for quantification of growth and productivity in anaerobic microbiology and biotechnology
Mauerhofer, L., Pappenreiter, P., Paulik, C., Seifert, A. H., Bernacchi, S., & Rittmann, S. K. ‐. R. (2018) · Folia Microbiologica · doi:10.1007/s12223-018-0658-4 · Cited by 93
Jian, X., Guo, X., Wang, J., Tan, Z. L., Xing, X., Wang, L., & Zhang, C. (2020) · Biotechnology and Bioengineering · doi:10.1002/bit.27327 · Cited by 80
Recent developments in the monitoring, modeling and control of biological production systems
Mandenius, C. (2004) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-004-0383-z · Cited by 76
Clementschitsch, F., Jürgen, K., Pötschacher, F., & Karl, B. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.05.030 · Cited by 73
Sensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Recent Advances in High Cell Density Cultivation for Production of Recombinant Protein
Shojaosadati, S. A., Kolaei, S. M. V., Babaeipour, V., et al. (2008) · Iranian Journal of Biotechnology · Cited by 64
Bäcker, M., Rakowski, D., Poghossian, A., Biselli, M., Wagner, P., & Schöning, M. J. (2012) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2012.03.014 · Cited by 61
Monitoring of eicosapentaenoic acid (EPA) production in the microalgae Nannochloropsis oceanica
Sá, M., Ferrer-Ledo, N., Wijffels, R., Crespo, J. G., Barbosa, M., & Galinha, C. F. (2020) · Algal Research · doi:10.1016/j.algal.2019.101766 · Cited by 58
Monitoring of Submerged Bioprocesses
Vaidyanathan, S., Macaloney, G., Vaughan, J., McNeil, B., & Harvey, L. M. (1999) · Critical Reviews in Biotechnology · doi:10.1080/0738-859991229161 · Cited by 58
Benchmarking real-time monitoring strategies for ethanol production from lignocellulosic biomass
López, P. C., Feldman, H., Mauricio‐Iglesias, M., Junicke, H., Huusom, J. K., & Gernaey, K. V. (2019) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2019.105296 · Cited by 83
Lechuga, L. M. (2005) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(05)44005-2 · Cited by 64
In-Situ-Fluorescence-Probes: A Useful Tool for Non-invasive Bioprocess Monitoring
Stärk, E., Hitzmann, B., Schügerl, K., Scheper, T. H., Fuchs, C., Köster, D., & Märkl, H. (2002) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-45736-4_2 · Cited by 62
Determination of cell mass and polymyxin using multi-wavelength fluorescence
Lantz, A. E., Jørgensen, P., Poulsen, E. C., Lindemann, C., & Lisbeth Olsson, A. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.08.007 · Cited by 52
Online monitoring of microcarrier based fibroblast cultivations with in situ microscopy
Rudolph, G., Lindner, P., Gierse, A., Bluma, A., Martínez, G., Hitzmann, B., & Scheper, T. H. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21523 · Cited by 44
Evaluation of spectrofluorometry as a tool for estimation in fed‐batch fermentations
Hagedorn, A., Legge, R. L., & Budman, H. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10649 · Cited by 40
Large-scale production and homogenous purification of long chain polysialic acids from E. coli K1
Rode, B., ENDRES, C., RAN, C., Stahl, F., Beutel, S., Kasper, C., Galuska, S. P., GEYER, R., Mühlenhoff, M., Gerardy‐Schahn, R., et al. (2008) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2008.03.012 · Cited by 54
Schalk, R., Heintz, A., Braun, F., Iacono, G., Rädle, M., Gretz, N., Methner, F., & Beuermann, T. (2019) · Applied Sciences · doi:10.3390/app9122472 · Cited by 39
Rehbock, C., Beutel, S., Brückerhoff, T., Hitzmann, B., Riechers, D., Rudolph, G., Stahl, F., Scheper, T. H., & Friehs, K. (2008) · Chemie Ingenieur Technik · doi:10.1002/cite.200700164 · Cited by 42
Ganzlin, M., Marose, S., Lü, X., Hitzmann, B., Scheper, T. H., & Rinas, U. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.08.032 · Cited by 31
Self-citationNoninvasive online biomass detector system for cultivation in shake flasks
Schmidt‐Hager, J., Ude, C., Findeis, M., John, G. T., Scheper, T. H., & Beutel, S. (2014) · Engineering in Life Sciences · doi:10.1002/elsc.201400026 · Cited by 30
Classification of two-dimensional fluorescence spectra using self-organizing maps
Rhee, J. I., Lee, K., Kim, C.-K., Yim, Y., Chung, S., Wei, J., & Bellgardt, K. ‐. (2004) · Biochemical Engineering Journal · doi:10.1016/j.bej.2004.09.008 · Cited by 30
Perspectives of fluorescence spectroscopy for online monitoring in microalgae industry
Sá, M., Ferrer‐Ledo, N., Gao, F., Bertinetto, C. G., Jansen, J., Crespo, J. G., Wijffels, R. H., Barbosa, M., & Galinha, C. F. (2022) · Microbial Biotechnology · doi:10.1111/1751-7915.14013 · Cited by 29
Chemical and biological characterisation of a sensor surface for bioprocess monitoring
Moore, J. D., Perez‐Pardo, M. A., Popplewell, J. F., Spencer, S. J., Ray, S., Swann, M. J., Shard, A. G., Jones, W., Hills, A. E., & Bracewell, D. G. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.11.043 · Cited by 24
Engineering Antibodies for Biosensor Technologies
Goodchild, S. A., Love, T. E., Hopkins, N., & Mayers, C. N. (2005) · Advances in applied microbiology · doi:10.1016/s0065-2164(05)58006-7 · Cited by 27
An LED array-based light induced fluorescence sensor for real-time process and field monitoring
Dickens, J. E., Vaughn, M. S., Taylor, M. L., & Ponstingl, M. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.04.077 · Cited by 25
Practices of shake-flask culture and advances in monitoring CO2 and O2
Takahashi, M., & Aoyagi, H. (2018) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-018-8922-8 · Cited by 24
Monitoring fermentation processes using in‐process measurements of different orders
Svendsen, C., Skov, T., & van den Berg, F. W. J. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4483 · Cited by 27
Musmann, C., Joeris, K., Markert, S., Solle, D., & Scheper, T. H. (2016) · Engineering in Life Sciences · doi:10.1002/elsc.201500122 · Cited by 23
Enzymatic Synthesis of Caged NADP Cofactors: Aqueous NADP Photorelease and Optical Properties
Salerno, C. P., Magde, D., & Patron, A. P. (2000) · The Journal of Organic Chemistry · doi:10.1021/jo9917846 · Cited by 22
On-line monitoring of process parameters during fermentation
Gargalo, C. L., López, P. C., Hasanzadeh, A., Udugama, I. A., & Gernaey, K. V. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91167-2.00003-4 · Cited by 35
Vaidyanathan, S., Macaloney, G., Harvey, L. M., & McNeil, B. W. J. (2001) · Applied Spectroscopy · doi:10.1366/0003702011951957 · Cited by 21
Characterization of a noninvasive on-line turbidity sensor in shake flasks for biomass measurements
Ebert, F. V., Reitz, C., Bournazou, M. N. C., & Neubauer, P. B. (2018) · Biochemical Engineering Journal · doi:10.1016/j.bej.2018.01.001 · Cited by 20
Process analytical technology (PAT) needs and applications in the bioprocess industry
Känsäkoski, M., Kurkinen, M., von Weymarn, N., & Niemelä, P. (2006) · Cited by 25
Vees, C. A., Veiter, L., Sax, F., Herwig, C., & Pflügl, S. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02423-z · Cited by 19
López Expósito, P., Blanco Suárez, A., & Negro Álvarez, C. (2017) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2016.12.020 · Cited by 17
Detection of chemicals using a novel fiber-optic sensor element built in fiber loop ring-resonators
Gangopadhyay, T. K., Giorgini, A., Halder, A., et al. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.09.024 · Cited by 17
In situ microscopy for online monitoring of cell concentration in Pichia pastoris cultivations
Marquard, D., Enders, A., Roth, G., Rinas, U., Scheper, T. H., & Lindner, P. (2016) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2016.07.024 · Cited by 19
OPTRODE-BASED FIBER OPTIC BIOSENSORS (BIO-OPTRODE)
Biran, I., Yu, X., & Walt, D. R. (2008) · Elsevier eBooks · doi:10.1016/b978-044453125-4.50003-6 · Cited by 31
Skouteris, G., Webb, D. P., Shin, K. L. F., et al. (2018) · Water Resources and Industry · doi:10.1016/j.wri.2018.10.002 · Cited by 17
Colorimetric pH measurement of animal cell culture media
Jang, J., Moon, S.-J., Hong, S.-H., & Kim, I. H. (2010) · Biotechnology Letters · doi:10.1007/s10529-010-0341-6 · Cited by 17
UV‐Visible Spectroscopy for On‐Line Analysis
Liauw, M., Baylor, L. C., & O’Rourke, P. E. (2010) · Wiley eBooks · doi:10.1002/9780470689592.ch4 · Cited by 22
Luminescence-Based Sensors for Bioprocess Applications
Urriza-Arsuaga, I., Ielasi, G., Bedoya, M., & Orellana, G. (2019) · Springer series on fluorescence · doi:10.1007/4243_2019_10 · Cited by 22
Fluorescence monitoring during cultivation of Enterobacter aerogenes at different oxygen levels
Mukherjee, J., Lindemann, C., & Scheper, T. V. O. (1999) · Applied Microbiology and Biotechnology · doi:10.1007/s002530051550 · Cited by 16
Lindner, P., Endres, C., Bluma, A., Höpfner, T., Glindkamp, A., Haake, C., Landgrebe, D., Riechers, D., Baumfalk, R., Hitzmann, B., et al. (2010) · Wiley eBooks · doi:10.1002/9780470909997.ch6 · Cited by 18
Real‐time update of calibration model for better monitoring of batch processes using spectroscopy
Kornmann, H., Valentinotti, S., Marison, I., & Stockar, U. V. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20153 · Cited by 12
Schwab, K., Amann, T., Schmid, J., Handrick, R., & Hesse, F. (2016) · Biotechnology Progress · doi:10.1002/btpr.2326 · Cited by 14
Yan, C., Wang, L., Ma, N., Wan, Y., Zhou, L., Zhu, X., & Qian, W. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340582 · Cited by 13
Advances in self-assembled Au-DNA nanomachines
Zhang, Q., Xu, S., Zheng, J., Zhang, J., & Zhu, J. (2023) · iScience · doi:10.1016/j.isci.2023.106327 · Cited by 13
Sampling and monitoring in bioprocessing using microtechniques
Gastrock, G., Lemke, K., & Metze, J. (2001) · Reviews in Molecular Biotechnology · doi:10.1016/s1389-0352(01)00034-4 · Cited by 11
Monitoring of an antigen manufacturing process
Zavatti, V., Budman, H. M., Legge, R. L., & Tamer, M. I. (2016) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-016-1565-1 · Cited by 9
A Review on Water Quality Monitoring Methods Based on Electronics and Optical Sensing
Razman, N. A., Ismail, W. Z. W., Kamil, N. A. I. M., et al. (2022) · Journal of Advanced Research in Applied Sciences and Engineering Technology · doi:10.37934/araset.26.2.17 · Cited by 9
Benavides, O. R., Gibbs, H. C., White, B. P., Kaunas, R. R., Gregory, C. A., Walsh, A. J., & Maitland, K. C. (2023) · PLoS ONE · doi:10.1371/journal.pone.0282298 · Cited by 11
Thermal profiling for parallel on-line monitoring of biomass growth in miniature stirred bioreactors
Gill, N. K., Appleton, M. S., & Lye, G. J. (2008) · Biotechnology Letters · doi:10.1007/s10529-008-9719-0 · Cited by 9
Boukazia, Y., Delaplace, G., Cadé, M., et al. (2020) · Food and Bioproducts Processing · doi:10.1016/j.fbp.2020.12.003 · Cited by 8
On-line monitoring of the denitrification process by measurement of NADH fluorescence
Lee, D., Song, S. H., Kim, J. H., & Yoo, Y. J. (2002) · Biotechnology Letters · doi:10.1023/a:1015577132408 · Cited by 9
03 Fermentation Technology and Bioreactor Design
Raj, A. E., & Karanth, N. G. (2005) · doi:10.1201/9781420027976-7 · Cited by 16
Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses
König, J. C., Steinwedel, T., Solle, D., Lindner, P., de Vries, I., Hentrop, T., Findeis, M., John, G. T., Scheper, T., & Beutel, S. (2018) · Journal of Sensors and Sensor Systems · doi:10.5194/jsss-7-461-2018 · Cited by 7
Yoosefian, S.-H., Ebrahimi, R., Bakhshipour, A., et al. (2023) · Journal of Material Cycles and Waste Management · doi:10.1007/s10163-023-01847-w · Cited by 7
Schäferling, M. (2016) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0206.pub3 · Cited by 7
Fluorescent Sensing and Process Analytical Applications
Dickens, J. E. (2010) · Wiley eBooks · doi:10.1002/9780470689592.ch11 · Cited by 6
Continuous Fermentation for Biopharmaceuticals?
Mears, L., Feldman, H., Falco, F. C., Bach, C., Wu, M., Nørregaard, A., & Gernaey, K. V. (2017) · Wiley eBooks · doi:10.1002/9781119001348.ch6 · Cited by 11
Online monitoring of fermentation processes in lignocelluloses-to-bioalcohol production
Lantz, A. E., Gernaey, K. V., Franzén, C. J., & Olsson, L. (2010) · Elsevier eBooks · doi:10.1533/9781845699611.4.315 · Cited by 8
A Self-Contained System With CNTs-Based Biosensors for Cell Culture Monitoring
Boero, C., Olivo, J., Carrara, S., & Micheli, G. D. (2012) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2012.2223592 · Cited by 5
Schott, C., Bley, T., Walter, T., Brusius, J., & Steingroewer, J. (2021) · Engineering in Life Sciences · doi:10.1002/elsc.202100086 · Cited by 5
Optrode-Based Fiber Optic Biosensors (Bio-Optrode)
Biran, I., & Walt, D. R. (2002) · Elsevier eBooks · doi:10.1016/b978-044450974-1/50001-x · Cited by 5
Integrierte Impedanzspektroskopie aerober Zellkulturen in biotechnologischen Hochdurchsatzscreenings
Hofmann, M., & Mokwa, W. (2009) · RWTH Publications (RWTH Aachen) · Cited by 5
Bioprocess monitoring by biosensor-based technologies
Göker, M., Kurbanoğlu, S., Huri, P. Y., Sezgintürk, M. K., & Özkan, S. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818592-6.00010-4 · Cited by 8
Fluorescence Techniques for Bioprocess Monitoring
Anton, F., Lindemann, C., Hitzmann, B., Reardon, K. F., & Scheper, T. H. (2010) · Wiley eBooks · doi:10.1002/9780470054581.eib632 · Cited by 5
Determination of glycated hemoglobin on the basis of spectral shifting from protein-dye interaction
Kim, E. J., Song, S. Y., Lee, B. Y., & Yoon, H. C. (2010) · BioChip Journal · doi:10.1007/s13206-010-4103-2 · Cited by 3
Schael, F., & Reich, O. (2001) · tm - Technisches Messen · doi:10.1524/teme.2001.68.10.448 · Cited by 3
Online Analysis and Process Control in Recombinant Protein Production (Review)
Palmer, S. M., & Kunji, E. R. S. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-770-5_12 · Cited by 4
The Application of Biorecognition
Wilchek, M., Hofstetter, H., & Hofstetter, O. (2000) · Springer eBooks · doi:10.1007/978-1-4615-1231-8_13 · Cited by 3
Advances in Sensor and Sampling Technologies in Fermentation and Mammalian Cell Culture
Arroyo, A. Y. (2014) · ASM Press eBooks · doi:10.1128/9781555816827.ch50 · Cited by 2
A brief review on biotechnological process sensoring
de Freitas, H. F. S., & Andrade, C. G. M. (2015) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi.2015.7494490 · Cited by 5
Schäferling, M. (2011) · Wiley eBooks · doi:10.1002/9780470027318.a0206.pub2 · Cited by 2
Molecular Beacon DNA Probes Based on Fluorescence Biosensing
John, M. S., Yao, G., & Tan, W. (2005) · CRC Press eBooks · doi:10.1201/9781420028287.ch4 · Cited by 2
Advancement of sensor technology for monitoring and control of upstream bioprocesses
Randek, J. (2020) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-165116 · Cited by 2
Ramakrishnan, A., & Sadana, A. (2002) · Birkhäuser Basel eBooks · doi:10.1007/978-3-0348-8127-2_11 · Cited by 1
Brennan, J. D. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0206 · Cited by 1
Influence of Nonspecific Binding on the Rate and Amount of Specific Binding: A Classical Analysis
Sadana, A. (2002) · Elsevier eBooks · doi:10.1016/b978-012613763-7/50023-9
On‐Line Analysis in Animal Cell Culture
Kretzmer, G. (2000) · Wiley eBooks · doi:10.1002/0471250570.spi082
Vibrational Spectroscopy in Bioprocess Monitoring
Ciurczak, E. W. (2005) · Informa Healthcare eBooks · doi:10.1201/9780824722258.ch14
NASCIMENTO, I. C. S., Dante, A., Valdman, A., et al. (2018) · Blucher Chemical Engineering Proceedings · doi:10.5151/cobeq2018-pt.0886
Manual técnico e de operação: sistema de monitoramento de turbidez
Costa, E. J. X., & Arce, A. I. C. (2019) · Universidade de São Paulo. Faculdade de Zootecnia e Engenharia de Alimentos eBooks · doi:10.11606/9788566404234
Rao, H. V., Masood, A. M., & Mukherjee, J. (2002) · Journal of Fluorescence · doi:10.1023/a:1016837523208
(2011) · CRC Press eBooks · doi:10.1201/b11472-15
Benavides, O. R., Gibbs, H. C., White, B. P., et al. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.09.19.508168
Metadata
- Authors
- Marose, S.
- Affiliations
- Leibniz University Hannover (DE)
- Corresponding author
- Marose, S
- Venue
- Trends in biotechnology
- Publisher
- Elsevier BV
- Published
- 1999-01-01
- Volume
- 17
- Issue
- 1
- Pages
- 30-34
- ISSN
- 0167-7799 (ISSN-L)
- OpenAlex
- W2062196667
- Cited by
- 102
- References
- 30
- Citations by year
- 2023: 3 · 2022: 4 · 2021: 2 · 2020: 7 · 2019: 5 · 2018: 8 · 2017: 2 · 2016: 6 · 2015: 2 · 2014: 4 · 2012: 4
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Trends in biotechnology (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Keywords
- optical sensors, bioprocess monitoring, in situ microscopy, optical biosensors, fiber optic sensors, infrared sensors, fluorescent sensors, continuous process monitoring, non-invasive sensing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.