Real‐time update of calibration model for better monitoring of batch processes using spectroscopy
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In order to reduce the large calibration matrix usually required for calibrating multiwavelength optical sensors, a simple algorithm based on the addition in process of new standards is proposed. A small calibration model, based on 14 standards, is periodically updated by spectra collected on‐line during fermentation operation. Concentrations related to these spectra are reconciled into best‐estimated values, by considering carbon and oxygen balances. Using this method, fructose, acetate, and gluconacetan were monitored during batch fermentations of Gluconacetobacter xylinus 12281 using mid‐infrared spectroscopy. It is shown that this algorithm compensates for noncalibrated events such as production or consumption of by‐products. The standard error of prediction (SEP) values were 0.99, 0.10, and 0.90 g/L for fructose, acetate, and gluconacetan, respectively. By contrast, without an updating of the calibration model, the SEP values were 2.46, 0.92, and 1.04 g/L for fructose, acetate, and gluconacetan, respectively. Using only 14 standards, it was therefore possible to approach the performance of an 88‐standard‐based calibration model having SEP values of 1.11, 0.37, and 0.79 g/L for fructose, acetate, and gluconacetan, respectively. Therefore, the proposed algorithm is a valuable approach to reduce the calibration time of multiwavelength optical sensors. © 2004 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In [40], MIR spectroscopy was used for in-line monitoring of 15 L G. xylinus bacterial fermentations.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [40]
In the citing paper
“Fructose and phosphate had errors of 6.94% and 5.63%, respectively, while ethanol and acetate were particularly accurate, with errors of 1.14% and 0.67%. Ammonium showed a low error of 1.47%. However, gluconacetan exhibited a higher error at 22.3%, likely due to spectral overlap and low absorbance.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [40]
In the citing paper
“Overall, the model provided reliable real-time monitoring, with the exception of some limitations for gluconacetan.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in monitoring, modeling and control of bioprocesses during the last 20 years
Schügerl, K. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00361-8 · Cited by 278
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Optical sensor systems for bioprocess monitoring
Marose, S. (1999) · Trends in biotechnology · doi:10.1016/s0167-7799(98)01247-5 · Cited by 102
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70 · cited 2×
“Recent studies have illustrated monitoring of glucose, ethanol (Sivakesava et al., 2001b), gibberellins (McGovern et al., 2002), and carotenoids (Cannizzaro et al., 2003) during fermentations.”
BackgroundSelf-citationMacedo, M. G., Laporte, M.-F., & Lacroix, C. (2002) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0110093 · Cited by 36
Research works printed but not linked: 38
- 10.1016/S0141-0229(00)00271-4 · DOI
- 10.1002/bit.10383 · DOI · Paper page
- Beebe KR, 1987, An intoduction to multivariate calibration and analysis, Anal Chem, 59, 1007, 10.1021/ac00144a725 · doi:10.1021/ac00144a725 · Paper page
- Cannizzaro C, 2002, Spectroscopic monitoring of bioprocesses: a study of carotenoid production by Phaffia rhodozyma yeast
- 10.1023/A:1026784101162 · DOI
- 10.1021/bp990039b · DOI
- 10.1002/(SICI)1097-0290(19980520)58:4<428::AID-BIT10>3.0.CO;2-7 · DOI
- 10.1007/BF00172716 · DOI
- 10.1366/0003702963904872 · DOI
- 10.1016/0003-2670(86)80028-9 · DOI · Paper page
- 10.1016/S0958-1669(02)00295-1 · DOI
- 10.1002/bit.10058 · DOI · Paper page
- 10.1366/0003702021954421 · DOI
- 10.1128/AEM.69.10.6091-6098.2003 · DOI
- 10.1007/s00253-003-1299-2 · DOI
- 10.1002/bit.10618 · DOI · Paper page
- 10.1016/S0925-4005(98)00195-6 · DOI
- Luttik MAH, 1997, The low biomass yields of the acetic‐acid bacterium Acetobacter pasteurianus are due to a low stoichiometry of respiration‐coupled proton translocation, Appl Environ Microbiol, 63, 3345, 10.1128/aem.63.9.3345-3351.1997 · DOI
- 10.1111/j.1365-2672.1993.tb03015.x · doi:10.1111/j.1365-2672.1993.tb03015.x
- MadronF VerverkaV VanécékV.1977.Statistical analysis of material balance of a chemical reactor.23:482–486. · DOI
- Martens H, 1988, Multivariate calibration
- 10.1002/bit.10226 · DOI · Paper page
- 10.1016/0003-2670(95)00226-P · doi:10.1016/0003-2670(95)00226-p
- NoormanHJ RomeinB LuybenKCAM HeijnenJJ.1996.Classification error‐detection and reconciliation of process information in complex biochemical systems49:364–376. · doi:10.1002/(sici)1097-0290(19960220)49:4<364::aid-bit2>3.0.co;2-n
- 10.1007/s004490100226 · DOI
- 10.1002/bit.10093 · DOI · Paper page
- 10.1002/bit.10134 · DOI · Paper page
- Schulze U, 1995, Anaerobic physiology of Saccharomyces cerevisiae
- 10.1016/S0032-9592(01)00223-0 · DOI
- 10.1038/sj.jim.7000124 · DOI · Paper page
- 10.1016/S0003-2670(00)85460-4 · DOI
- Standard practice for qualifying spectrometers and spectrophotometers for use in multivariate analyses, calibrated using surrogate mixtures, 2000, Annual book of ASTM standards, 718
- Standard practice for infrared, multivariate, quantitative analysis (e 1655‐97), 1999, Annual book of ASTM standards, 844
- 10.1080/0738-859991229161 · DOI · Paper page
- 10.1002/bit.260430104 · DOI
- 10.1002/bit.260250906 · DOI · Paper page
- Wold S, 1984, Chemometrics, mathematics and statistics in chemistry, 17
- 10.1016/S0961-9534(02)00019-3 · DOI
Cited by
Podevin, M., Fotidis, I. A., & Angelidaki, I. (2018) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2017.1398132 · Cited by 34
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“In [40], MIR spectroscopy was used for in-line monitoring of 15 L G. xylinus bacterial fermentations.”
Metadata
- Authors
- Kornmann, H., Valentinotti, S., Marison, I., & Stockar, U. V.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2004-08-17
- Volume
- 87
- Issue
- 5
- Pages
- 593-601
- ISSN
- 0006-3592
- 1097-0290
- Cited by
- 12
- References
- 5
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐time update of calibration model for better monitoring of batch processes using spectroscopy. https://app.cochat.ai/papers/10.1002/bit.20153
- The paper
- Kornmann, H., Valentinotti, S., Marison, I., & Stockar, U. V. (2004). Real‐time update of calibration model for better monitoring of batch processes using spectroscopy. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.20153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.