Incidence of pulmonary vein stenosis 2 years after radiofrequency catheter ablation of refractory atrial fibrillation
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
AIMS: Pulmonary vein ablation offers the potential to cure patients with atrial fibrillation. In this study, we investigated the incidence of pulmonary vein stenosis after radiofrequency catheter ablation of refractory atrial fibrillation by systematic long-term follow-up. METHODS AND RESULTS: Forty-seven patients with refractory and highly symptomatic atrial fibrillation underwent radiofrequency catheter ablation of arrhythmogenic triggers inside the pulmonary veins and/or ostial pulmonary vein isolation with conventional mapping and ablation technology. These patients had follow-up examinations at 2 years with transoesophageal doppler-echo and/or angio magnetic resonance imaging for the evaluation of the pulmonary veins. Seventy-seven percent of the patients were free from atrial fibrillation, 51% were without antiarrhythmic drugs, and 26% were on previously ineffective antiarrhythmic drug therapy. However, 13 of the 47 patients showed significant pulmonary vein stenosis or occlusion. Only three of these 13 patients complained of dyspnoea. Distal ablations inside the pulmonary vein were associated with a 5.6-fold higher risk of stenosis than ostial ablations. CONCLUSIONS: At 2-year follow-up, the risk of significant pulmonary vein stenosis/occlusion after radiofrequency catheter ablation of refractory atrial fibrillation with conventional mapping and ablation technology was 28%. Distal ablations inside smaller pulmonary veins should be avoided because of the higher risk of stenosis than ablation at the ostium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., Salvati, A., Dicandia, C., Mazzone, P., Santinelli, V., et al. (2000) · Circulation · doi:10.1161/01.cir.102.21.2619 · Cited by 1,358
Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.20.2463 · Cited by 952
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Pappone, C., Oreto, G., Rosanio, S., Vicedomini, G., Tocchi, M., Gugliotta, F., Salvati, A., Dicandia, C., Calabrò, M. P., Mazzone, P., et al. (2001) · Circulation · doi:10.1161/hc4601.098517 · Cited by 863
Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N. (1998) · Circulation · doi:10.1161/01.cir.98.17.1769 · Cited by 443
Natale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., Santarelli, P., Schweikert, R., White, R., Saliba, W., et al. (2000) · Circulation · doi:10.1161/01.cir.102.16.1879 · Cited by 275
Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs
Taylor, G. W., Kay, G. N., Zheng, X., Bishop, S., & Ideker, R. E. (2000) · Circulation · doi:10.1161/01.cir.101.14.1736 · Cited by 239
YU, W., HSU, T., TAI, C., TSAI, C., HSIEH, M., LIN, W., LIN, Y., TSAO, H., DING, Y., CHANG, M., et al. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00887.x · Cited by 185 · cited 2×
“a maximum pulmonary vein doppler flow velocity of ≥110 cm/s corresponding to data published by Yu et al.(5) and 2.”
BackgroundMethod
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Calkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847
Calkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Metadata
- Authors
- Arentz, T.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-05
- Volume
- 24
- Issue
- 10
- Pages
- 963-969
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2105689449
- Cited by
- 174
- References
- 10
- FWCI
- 11.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.