Imaging of the elastic properties of tissue—A review
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Recently, a number of methods have been developed that make it possible to image the elastic properties of soft tissues. Because certain types of tissues such as malignant lesions, for example, have elastic properties that are markedly different from surrounding tissues, elasticity imaging could provide a significant adjunct to current diagnostic ultrasonic methods. Further, elasticity imaging techniques could be used to augment the study of tissues that change their elastic properties, such as skeletal and cardiac muscle. In this paper, we survey some of the previous work done in the related field of biomechanics, and we review measurement techniques from the 1950s to the 1980s. Different approaches to elastic imaging and signal processing are then discussed and a lexicography for elastic imaging is introduced. It is hoped that this nomenclature will provide a meaningful categorization of various approaches and will make evident the inherent parameters displayed and conditions applied in deriving the resulting images. Key assumptions and signal processing approaches are also reviewed. Finally, directions for future work are suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Elasticity : theory and applications
Saada, A. S. (1993) · Cited by 676
Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.172.2.2748813 · Cited by 597
Proceedings of IEEE Ultrasonics Symposium
(1994) · Proceedings of IEEE Ultrasonics Symposium ULTSYM-94 · doi:10.1109/ultsym.1994.401541 · Cited by 546
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
Self-citationTissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Self-citation
Cited by
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
On the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731
Ultrasound-Stimulated Vibro-Acoustic Spectrography
Fatemi, M., & Greenleaf, J. F. (1998) · Science · doi:10.1126/science.280.5360.82 · Cited by 642
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity
Chen, S., Urban, M., Pislaru, C., Kinnick, R., Zheng, Y., Yao, A., & Greenleaf, J. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1005 · Cited by 522
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Self-citationShear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412
Vibro-acoustography: An imaging modality based on ultrasound-stimulated acoustic emission
Fatemi, M., & Greenleaf, J. F. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6603 · Cited by 385
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Spatio-temporal directional filtering for improved inversion of MR elastography images
Manduca, A., Lake, D. S., Kruse, S. A., & Ehman, R. L. (2003) · Medical Image Analysis · doi:10.1016/s1361-8415(03)00038-0 · Cited by 344
Iglesias–Garcia, J., Larino–Noia, J., Abdulkader, I., Forteza, J., & Dominguez–Munoz, J. E. (2010) · Gastroenterology · doi:10.1053/j.gastro.2010.06.059 · Cited by 314
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Tissue elasticity properties as biomarkers for prostate cancer
Hoyt, K., Castaneda, B., Zhang, M., Nigwekar, P., di Sant'Agnese, P. A., Joseph, J. V., Strang, J., Rubens, D. J., & Parker, K. J. (2008) · Cancer Biomarkers · doi:10.3233/cbm-2008-44-505 · Cited by 303
Self-citationWells, P. N. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r06 · Cited by 287
Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging
Sandrin, L., Catheline, S., Tanter, M., Hennequin, X., & Fink, M. (1999) · Ultrasonic Imaging · doi:10.1177/016173469902100402 · Cited by 267
Diagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules
Moon, H. J., Sung, J. M., Kim, E.-K., Yoon, J. H., Youk, J. H., & Kwak, J. Y. (2012) · Radiology · doi:10.1148/radiol.11110839 · Cited by 251
“Elastography has been introduced to evaluate the tissue hardness objectively and to augment the diagnostic accuracy of gray-scale ultrasonography (US) (5,6).”
BackgroundReview of MR elastography applications and recent developments
Glaser, K. J., Manduca, A., & Ehman, R. L. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23597 · Cited by 245
2-D companding for noise reduction in strain imaging
Chaturvedi, P., Insana, M. F., & Hall, T. J. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.646923 · Cited by 231
Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review
Misra, S., Ramesh, K. T., & Okamura, A. M. (2008) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.17.5.463 · Cited by 219
“Depending on the method of tissue deformation and parameters that are imaged, different terms are used to describe the images obtained, including strain, stress, velocity, amplitude, phase, vibration, compression, quasistatic, and functional images (Gao, Parker, Lerner, & Levinson, 1996).”
MethodEUS elastography for the characterization of solid pancreatic masses
Iglesias-Garcia, J., Larino-Noia, J., Abdulkader, I., Forteza, J., & Dominguez-Munoz, J. E. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.05.011 · Cited by 194
Elastographic characterization of HIFU-induced lesions in canine livers
Righetti, R., Kallel, F., Stafford, R. J., Price, R. E., Krouskop, T. A., Hazle, J. D., & Ophir, J. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00044-7 · Cited by 193
“Recently, methods to map information related to the elastic properties of soft tissues have been proposed, as reviewed by Gao et al. (1996).”
MethodZheng, Y. P., Chan, M. M. F., Shi, J., Chen, X., & Huang, Q. H. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.012 · Cited by 181
Real-Time Regularized Ultrasound Elastography
Rivaz, H., Boctor, E. M., Choti, M. A., & Hager, G. D. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2091966 · Cited by 177
“Among many variations of ultrasound elastography [1]–[4], our work focuses on real-time static elastography, a well-known technique that applies quasi-static compression of tissue and simultaneously images it with ultrasound.”
BackgroundMagnetic Resonance Elastography of Liver
Venkatesh, S. K., & Ehman, R. L. (2014) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2014.05.001 · Cited by 174
Zhou, J., Zhan, W., Chang, C., Zhang, X., Jia, Y., Dong, Y., Zhou, C., Sun, J., & Grant, E. G. (2014) · Radiology · doi:10.1148/radiol.14130818 · Cited by 173
“Twenty-eight patients were excluded for the following reasons: US data acquisition was inadequate in four patients, 12 patients had a simple breast cyst, and pathologic diagnosis was E lastography enables differentiation of tissues on the basis of their stiffness (1,2).”
BackgroundThree-dimensional sonoelastography: principles and practices
Taylor, L. S., Porter, B. C., Rubens, D. J., & Parker, K. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/306 · Cited by 168
Self-citationGeneral review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Metadata
- Authors
- Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 1996
- Volume
- 22
- Issue
- 8
- Pages
- 959-977
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2143703219
- Cited by
- 514
- References
- 38
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.