High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
The DOI matches its Crossref record; 58 of the 60 references it cites were found in a registry or an index.
Abstract
The trend towards assay miniaturization for high-throughput and ultra-high-throughput screening continues to spur development of homogeneous, fluorescence-based assays in higher density, smaller volume microplate formats. Recently, first-generation microfluidic devices have been designed for performing continuous-flow biochemical and cell-based assays. These devices provide orders-of-magnitude reduction in reagent consumption, and offer the potential for implementing high-throughput screening in formats that integrate up-front compound handling with unique assay functionality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rapid evaporation in microtiter plates is an acknowledged issue [41, 42].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [41]
Citations
Cites
Fluorescence Energy Transfer as a Spectroscopic Ruler
Stryer, L. (1978) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.47.070178.004131 · Cited by 2,406
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
A dual-luciferase reporter system for studying recoding signals.
Grentzmann, G., Ingram, J. A., Kelly, P. J., Gesteland, R. F., & Atkins, J. F. (1998) · PubMed · Cited by 406
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Microchip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
A review of recent trends in analytical applications of electrogenerated chemiluminescence
Knight, A. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00086-7 · Cited by 329
Rapid screening of environmental chemicals for estrogen receptor binding capacity.
Bolger, R., Wiese, T. E., Ervin, K., Nestich, S., & Checovich, W. (1998) · Environmental Health Perspectives · doi:10.1289/ehp.98106551 · Cited by 316
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Fluorescence correlation spectroscopy: lead discovery by miniaturized HTS
Auer, M., Moore, K. J. M., Meyer‐Almes, F., Guenther, R., Pope, A. J., & Stoeckli, K. A. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01240-9 · Cited by 241
Cited by
Items 101–200 of 506
High-throughput screening of biomolecules using cell-free gene expression systems
Contreras-Llano, L. E., & Tan, C. (2018) · Synthetic Biology · doi:10.1093/synbio/ysy012 · Cited by 83
Tran, T. B., Cho, S., & Min, J. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.07.019 · Cited by 79
RNA Conformation and Folding Studied with Fluorescence Resonance Energy Transfer
Klostermeier, D., & Millar, D. P. (2001) · Methods · doi:10.1006/meth.2000.1135 · Cited by 79
Mirror‐image Phage Display: Aiming at the Mirror
Wiesehan, K., & Willbold, D. (2003) · ChemBioChem · doi:10.1002/cbic.200300570 · Cited by 77
Hot Brownian Particles and Photothermal Correlation Spectroscopy
Radünz, R., Rings, D., Kroy, K., & Cichos, F. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp810466y · Cited by 79
Cheng, Y., Luo, X., Tsao, C., Wu, H., Betz, J. F., Payne, G. F., Bentley, W. E., & Rubloff, G. W. (2011) · Lab on a Chip · doi:10.1039/c1lc20306a · Cited by 75
Medcalf, E. J., Gantz, M., Kamiński, T. S., & Hollfelder, F. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04144 · Cited by 73
Hydrogels and microtechnologies for engineering the cellular microenvironment
Gauvin, R., Parenteau‐Bareil, R., Dokmeci, M. R., Merryman, W. D., & Khademhosseini, A. (2012) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.171 · Cited by 72
Neggers, J., Allix, O., Hild, F., & Roux, S. (2017) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-017-9234-3 · Cited by 69
High-throughput high-performance liquid chromatography/mass spectrometry for modern drug discovery
Kyranos, J. N., Cai, H., Wei, D., & Goetzinger, W. K. (2001) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00176-2 · Cited by 69
Min, D., Yeo, W., & Mrksich, M. (2004) · Analytical Chemistry · doi:10.1021/ac049816z · Cited by 68
High-throughput cell analysis using multiplexed array technologies
Beske, O. E., & Goldbard, S. (2002) · Drug Discovery Today · doi:10.1016/s1359-6446(02)02388-7 · Cited by 66
Analysis of large libraries of protein mutants using flow cytometry
Georgiou, G. (2001) · Advances in protein chemistry · doi:10.1016/s0065-3233(01)55007-x · Cited by 64
Rapid Prototyping of Microstructures by Soft Lithography for Biotechnology
Wolfe, D. B., Qin, D., & Whitesides, G. M. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-106-6_3 · Cited by 62
Nishi, M., Akutsu, H., Kudoh, A., Kimura, H., Yamamoto, N., Umezawa, A., Lee, S. W., & Ryo, A. (2014) · Oncotarget · doi:10.18632/oncotarget.2356 · Cited by 62
3D Droplet Microfluidic Systems for High-Throughput Biological Experimentation
Kang, D., Gong, X., Cho, S., Kim, J., Edel, J. B., Chang, S., Choo, J., & deMello, A. J. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02402 · Cited by 61
Microfluidic Devices and Their Applications
Aryasomayajula, A., Bayat, P., Rezai, P., & Selvaganapathy, P. R. (2017) · Springer handbooks · doi:10.1007/978-3-662-54357-3_16 · Cited by 60
Boreham, A., Brodwolf, R., Walker, K., Haag, R., & Alexiev, U. (2016) · Molecules · doi:10.3390/molecules22010017 · Cited by 59
Gröll, J., Haubensak, W. E., Ameringer, T., & Möller, M. (2005) · Langmuir · doi:10.1021/la047438n · Cited by 59
A Microfluidic Device for Measuring Cellular Membrane Potential
Farinas, J., Chow, A. W., & Wada, H. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5202 · Cited by 59
Liu, Y., Gerber, R., Wu, J. Y. J., Tsuruda, T. S., & McCarter, J. D. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.02.018 · Cited by 61
A robust high-throughput sandwich cell-based drug screening platform
Zhang, S., Tong, W., Zheng, B., Susanto, T. A. K., Xia, L., Zhang, C., Ananthanarayanan, A., Tuo, X., Sakban, R. B., Jia, R., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.064 · Cited by 58
Silicon Photomultipliers and SPAD imagers in biophotonics: Advances and perspectives
Caccia, M., Nardo, L., Santoro, R., & Schaffhauser, D. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.10.204 · Cited by 58
Functional cell-based uHTS in chemical genomic drug discovery
Croston, G. E. (2002) · Trends in biotechnology · doi:10.1016/s0167-7799(02)01906-6 · Cited by 57
Combinatorial microelectrochemistry: Development and evaluation of an electrochemical robotic system
Erichsen, T. J., Reiter, S., Ryabova, V., Bonsen, E. M., Schuhmann, W. W., Märkle, W., Tittel, C., Jung, G., & Speiser, B. (2005) · Review of Scientific Instruments · doi:10.1063/1.1906106 · Cited by 56
High-throughput microfluidics: improved sample treatment and washing over standard wells
Warrick, J. W., Meyvantsson, I., Ju, J., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b613350a · Cited by 57
Deng, C., Ying, W., & Xinwang, Y. (2026) · 动物学研究 · doi:10.24272/j.issn.2095-8137.2026.076 · Cited by 55
Microfluidics for cell-based assays
Pihl, J., Sinclair, J., Karlsson, M., & Orwar, O. (2005) · Materials Today · doi:10.1016/s1369-7021(05)71224-4 · Cited by 57
Walt, D. R. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00372-1 · Cited by 54
Microfluidic devices for cell based high throughput screening
Upadhyaya, S., & Selvaganapathy, P. R. (2010) · Lab on a Chip · doi:10.1039/b918291h · Cited by 53
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Human skin equivalent as an alternative to animal testing.
Mertsching, H., Weimer, M., Kersen, S., & Brunner, H. (2008) · PubMed Central · Cited by 52
Wikswo, J. P., Prokop, A., Baudenbacher, F., Cliffel, D., Csukas, B., & Velkovsky, M. (2006) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20050045 · Cited by 51
Droplet splitting in microfluidics: A review
Agnihotri, S. N., Raveshi, M. R., Nosrati, R., Bhardwaj, R., & Neild, A. (2025) · Physics of Fluids · doi:10.1063/5.0267868 · Cited by 51
Forsberg, E. M., Green, J. R. A., & Brennan, J. D. (2011) · Analytical Chemistry · doi:10.1021/ac200534t · Cited by 51
Formulation Development of Antibodies Using Robotic System and High-Throughput Laboratory (HTL)
Zhao, H., Graf, O., Milović, N. M., Luan, X., Bluemel, M., Smolny, M., & Forrer, K. (2009) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22008 · Cited by 51
Optical microplates for high-throughput screening of photosynthesis in lipid-producing algae
Chen, M., Mertiri, T., Holland, T., & Basu, A. S. (2012) · Lab on a Chip · doi:10.1039/c2lc40478h · Cited by 50
Single cell kinase signaling assay using pinched flow coupled droplet microfluidics
Ramji, R., Wang, M., Bhagat, A. A. S., Weng, D. T. S., Thakor, N. V., Lim, C. T., & Chen, C. (2014) · Biomicrofluidics · doi:10.1063/1.4878635 · Cited by 46
Faster, better, and cheaper: harnessing microfluidics and mass spectrometry for biotechnology
Ha, N. S., de Raad, M., Han, L. Z., Golini, A. N., Petzold, C. J., & Northen, T. R. (2021) · RSC Chemical Biology · doi:10.1039/d1cb00112d · Cited by 45
Cheow, L. F., Viswanathan, R., Chin, C.-S., Jennifer, N., Jones, R. C., Guccione, E., Quake, S. R., & Burkholder, W. F. (2014) · Analytical Chemistry · doi:10.1021/ac502605f · Cited by 45
Developments in fluorescence lifetime-based analysis for ultra-HTS
Turconi, S., Bingham, R. P., Haupts, U. M., & Pope, A. J. (2001) · Drug Discovery Today · doi:10.1016/s1359-6446(01)00159-3 · Cited by 45
Ma, H., Horiuchi, K. Y., Wang, Y., Kucharewicz, S., & Diamond, S. L. (2005) · Assay and Drug Development Technologies · doi:10.1089/adt.2005.3.177 · Cited by 46
Fluorescence resonance energy transfer disposable sensor for copper(II)
Cano-Raya, C., Fernández-Ramos, M. D., & Capitán-Vallvey, L. F. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.09.011 · Cited by 45
Comparison of On-Chip and Off-Chip Microfluidic Kinase Assay Formats
Dunne, J., Reardon, H. T., Trinh, V., Li, E., & Farinas, J. (2004) · Assay and Drug Development Technologies · doi:10.1089/154065804323056468 · Cited by 46
Dainiak, M. B., Savina, I. N., Musolino, I., Kumar, A., Mattìasson, B., & Galaev, I. Y. (2008) · Biotechnology Progress · doi:10.1002/btpr.30 · Cited by 44
Drug Repurposing for Epigenetic Targets Guided by Computational Methods
Naveja, J. J., Dueñas‐González, A., & Medina‐Franco, J. L. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802808-7.00012-5 · Cited by 43
Liu, M. C., Ho, D., & Tai, Y. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.09.074 · Cited by 42
Advancing high-throughput screening systems for synthetic biology and biofoundry
Kwon, K. K., Lee, J., Kim, H., Lee, D., & Lee, S. (2023) · Current Opinion in Systems Biology · doi:10.1016/j.coisb.2023.100487 · Cited by 41
Briones, J., Espulgar, W. V., Koyama, S., Takamatsu, H., Tamiya, E., & Saito, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-92472-w · Cited by 40
HIGH-THROUGHPUT MASS SPECTROMETRIC ANALYSIS OF XENOBIOTICS IN BIOLOGICAL FLUIDS
Bakhtiar, R., Ramos, L., & Tse, F. L. S. (2002) · Journal of Liquid Chromatography & Related Technologies · doi:10.1081/jlc-120008809 · Cited by 40
Cellular screening assays using fluorescence microscopy
Blake, R. (2001) · Current Opinion in Pharmacology · doi:10.1016/s1471-4892(01)00092-3 · Cited by 39
Cell-based high-throughput odorant screening system through visualization on a microwell array
Oh, E. H., Lee, S. H., Lee, S. H., Ko, H. J., & Park, T. H. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.09.039 · Cited by 38
An efficient planar accordion-shaped micromixer: from biochemical mixing to biological application
Cosentino, A., Madadi, H., Vergara, P., Vecchione, R., Causa, F., & Netti, P. A. (2015) · Scientific Reports · doi:10.1038/srep17876 · Cited by 38
Gubler, H., Clare, N., Galafassi, L., Geissler, U., Girod, M., & Herr, G. (2018) · SLAS DISCOVERY · doi:10.1177/2472555217752140 · Cited by 38
Solution-Phase Synthesis of a Highly Substituted Furan Library
Cho, C., Shi, F., Jung, D., Neuenswander, B., Lushington, G. H., & Larock, R. C. (2012) · ACS Combinatorial Science · doi:10.1021/co300040q · Cited by 38
Finding the needle in the haystack: why high-throughput screening is good for your health
Aherne, G. W., McDonald, E., & Workman, P. (2002) · Breast Cancer Research · doi:10.1186/bcr440 · Cited by 39
Microchip-based systems for target validation and HTS
Sundberg, S. A., Chow, A. W., Nikiforov, T. T., & Wada, H. (2000) · Drug Discovery Today · doi:10.1016/s1359-6446(00)80100-2 · Cited by 38
Self-citationWu, X. Y., Sills, M. A., & Zhang, J.-H. (2005) · SLAS DISCOVERY · doi:10.1177/1087057105275628 · Cited by 35
Zhra, M., Qasem, R. J., Aldossari, F., Saleem, R. A., & Aljada, A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25105460 · Cited by 34
Patient-derived stem cells: pathways to drug discovery for brain diseases
Mackay‐Sim, A. (2013) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2013.00029 · Cited by 34
Lindner, E., Lu, Z., Mayer, H. A., Speiser, B., Tittel, C., & Warad, I. (2005) · Electrochemistry Communications · doi:10.1016/j.elecom.2005.07.002 · Cited by 34
Generation of Equally Sized Particle Plaques Using Solid-Liquid Suspensions
Herrmann, T., Schroder, M., & Hubbuch, J. J. (2006) · Biotechnology Progress · doi:10.1021/bp050296i · Cited by 34
Plasma-polymerized coatings for bio-MEMS applications
Bouaidat, S., Winther‐Jensen, B., Christensen, S. F., & Jonsmann, J. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.10.032 · Cited by 34
High throughput single molecule detection for monitoring biochemical reactions
Okagbare, P. I., & Soper, S. A. (2008) · The Analyst · doi:10.1039/b816383a · Cited by 33
Modern analytical approaches to high-throughput drug discovery
Gómez‐Hens, A., & Aguilar-Caballos, M. P. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2006.12.001 · Cited by 33
Establishment and Maintenance of HIV Latency: Model Systems and Opportunities for Intervention
Marsden, M. D., & Zack, J. A. (2009) · Future Virology · doi:10.2217/fvl.09.70 · Cited by 32
New Tools and New Biology: Recent Miniaturized Systems for Molecular and Cellular Biology
Hamon, M., & Hong, J. W. (2013) · Molecules and Cells · doi:10.1007/s10059-013-0333-1 · Cited by 31
3D Cell-Based High-Content Screening (HCS) Using a Micropillar and Microwell Chip Platform
Lee, S., Doh, I., Nam, D., & Lee, D. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05328 · Cited by 31
Barbara, J. E., Eyler, J. R., & Powell, D. H. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3837 · Cited by 31
Designing chiral libraries for drug discovery
Beroza, P. (2000) · Drug Discovery Today · doi:10.1016/s1359-6446(00)01515-4 · Cited by 31
Assay Concordance between SPA and TR-FRET in High-Throughput Screening
von Ahsen, O., Schmidt, A., Klotz, M., & Parczyk, K. (2006) · SLAS DISCOVERY · doi:10.1177/1087057106288183 · Cited by 31
A scalable active micro-mixer for biomedical applications
Cortelezzi, L., Ferrari, S., & Dubini, G. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-1868-9 · Cited by 30
Intein mediated high throughput screening for bispecific antibodies
Hofmann, T., Schmidt, J., Ciesielski, E., Becker, S., Rysiok, T., Schütte, M., Toleikis, L., Kolmar, H., & Doerner, A. (2020) · mAbs · doi:10.1080/19420862.2020.1731938 · Cited by 30
Polymer Microstructures Fabricated via Laser Ablation Used for Multianalyte Protein Microassay
Ivanova, E. P., Wright, J. P., Pham, D. K., Filipponi, L., Viezzoli, A., & Nicolau, D. V. (2002) · Langmuir · doi:10.1021/la0260178 · Cited by 30
A microfluidic chip for controlled release of drugs from microcapsules
Cheng, W.-C., He, Y., Chang, A., & Que, L. (2013) · Biomicrofluidics · doi:10.1063/1.4829776 · Cited by 29
Ha, S., Seidle, T., & Lim, K. (2016) · Environmental Health and Toxicology · doi:10.5620/eht.e2016026 · Cited by 29
Modern methods of drug discovery: An introduction
Giersiefen, H., Hilgenfeld, R., & Hillisch, A. (2003) · Birkhäuser Basel eBooks · doi:10.1007/978-3-0348-7997-2_1 · Cited by 29
Nanoarrays: A Method for Performing Enzymatic Assays
Dietrich, H. R. C., Knoll, J., van den Doel, L. R., van Dedem, G. W. K., Daran-Lapujade, P. A. S., van Vliet, L. J., Moerman, R., Pronk, J. T., & Young, I. T. (2004) · Analytical Chemistry · doi:10.1021/ac049737n · Cited by 29
Pascoe, R. J., Masucci, J. A., & Foley, J. P. (2006) · Electrophoresis · doi:10.1002/elps.200500647 · Cited by 29
Lee, J., & Kim, M. (2022) · Biosensors · doi:10.3390/bios12100838 · Cited by 28
Hoseinpour, B., & Sarreshtehdari, A. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.111736 · Cited by 28
The Potential of Bioartificial Tissues in Oncology Research and Treatment
Walles, T., Weimer, M., Linke, K., Michaelis, J., & Mertsching, H. (2007) · Oncology Research and Treatment · doi:10.1159/000102544 · Cited by 28
Investigating the Function of Ion Channels in Tethered Lipid Membranes by Impedance Spectroscopy
Terrettaz, S., & Vogel, H. (2005) · MRS Bulletin · doi:10.1557/mrs2005.54 · Cited by 28
Cellular microarrays for use with capillary-driven microfluidics
Lovchik, R. D., von Arx, C., Viviani, A., & Delamarche, E. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1436-3 · Cited by 27
Fluorescence Correlation Spectroscopy (FCS)
Pramanik, A., & Widengren, J. (2006) · Wiley-VCH eBooks · doi:10.1002/3527600906.mcb.200300170 · Cited by 27
Morphological Profiling Identifies the Motor Protein Eg5 as Cellular Target of Spirooxindoles
Liu, J., Mallick, S., Xie, Y., Grassin, C., Lucas, B., Schölermann, B., Pahl, A., Scheel, R., Strohmann, C., Protzel, C., et al. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202301955 · Cited by 26
Patil, P. D., Gargate, N., Dongarsane, K., Jagtap, H., Phirke, A. N., Tiwari, M. S., & Nadar, S. S. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.136193 · Cited by 26
Proteome-wide microarray-based screening of PAR-binding proteins
Kang, B. G., Kang, S.-U., Kim, J. J., Kwon, J.-S., Gagné, J., Lee, S. Y., Kim, S., Lee, K. S., Ha, S., Jeong, J. S., et al. (2025) · Nucleic Acids Research · doi:10.1093/nar/gkaf300 · Cited by 26
Zguris, J. C., Itle, L. J., Koh, W., & Pishko, M. V. (2005) · Langmuir · doi:10.1021/la0470176 · Cited by 26
Gustafsdottir, S., Wennström, S., Fredriksson, S., Schallmeiner, E., Hamilton, A. D., Sebti, S. M., & Landegren, U. D. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.099424 · Cited by 26
Agonist-induced calcium response in single human platelets assayed in a microfluidic device
Tran, L., Farinas, J., Ruslim-Litrus, L., Conley, P. B., Muir, C., Munnelly, K., Sedlock, D. M., & Cherbavaz, D. B. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.02.024 · Cited by 25
Microfluidic encapsulation of cells in alginate capsules for high throughput screening
Trivedi, V. A., Ereifej, E. S., Doshi, A., Sehgal, P., VandeVord, P. J., & Basu, A. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333308 · Cited by 25
Holographic Enzyme Inhibition Assays for Drug Discovery
Tan, E. V., & Lowe, C. R. (2009) · Analytical Chemistry · doi:10.1021/ac9008989 · Cited by 25
Data Shaving: A Focused Screening Approach
Schreyer, S. K., Parker, C. N., & Maggiora, G. M. (2004) · Journal of Chemical Information and Computer Sciences · doi:10.1021/ci030025s · Cited by 25
Robotic automation of droplet microfluidics
Tran, T. M., Kim, S., Modavi, C., & Abate, A. R. (2022) · Biomicrofluidics · doi:10.1063/5.0064265 · Cited by 24
Drug discovery and development
Rang, H. P., Dale, M. M., Ritter, J., & Flower, R. (2007) · Elsevier eBooks · doi:10.1016/b978-0-443-06911-6.50061-x · Cited by 24
Miniaturization and parallelization of fluorescence immunoassays in nanotiter plates
Seidel, M., & Gauglitz, G. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00606-x · Cited by 24
Hydrodynamic simulation of cell docking in microfluidic channels with different dam structures
Yang, J., Li, C., & Yang, M. (2004) · Lab on a Chip · doi:10.1039/b309940g · Cited by 23
Unified 2D and 3D cell-based high-throughput screening platform using a micropillar/microwell chip
Lee, D. W., Doh, I., & Nam, D. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.011 · Cited by 23
Lighting E. coli cells as biological sensors for Cd2+
Prachayasittikul, V., Isarankura‐Na‐Ayudhya, C., & Bülow, L. (2001) · Biotechnology Letters · doi:10.1023/a:1010561120720 · Cited by 23
Metadata
- Authors
- Sundberg, S.
- Corresponding author
- Sundberg, S
- Venue
- Current Opinion in Biotechnology
- Publisher
- Elsevier BV
- Published
- 2000-02-01
- Volume
- 11
- Issue
- 1
- Pages
- 47-53
- ISSN
- 0958-1669 (ISSN-L)
- OpenAlex
- W2097654801
- Semantic Scholar
- fb023ffa634810b17ac638c4e313a5433e8dab90
- Cited by
- 455
- References
- 60
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 6 · 2023: 14 · 2022: 10 · 2021: 6 · 2020: 11 · 2019: 8 · 2018: 16 · 2017: 23 · 2016: 16 · 2015: 19 · 2014: 15 · 2013: 24 · 2012: 25
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Current Opinion in Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Keywords
- high-throughput screening, ultra-high-throughput screening, assay miniaturization, microfluidics, cell-based assays, reagent consumption reduction
- MeSH terms
- Animals, Biotechnology, Cells, Drug Evaluation, Preclinical, Enzymes, Fluorescence, Humans, Ligands, Microchemistry, Protein Binding, Solutions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.