Proteome analysis using selective incorporation of isotopically labeled amino acids
The DOI matches its Crossref record.
Abstract
A method is described for identifying intact proteins from genomic databases using a combination of accurate molecular mass measurements and partial amino acid content. An initial demonstration was conducted for proteins isolated from Escherichia coli (E. coli) using a multiple auxotrophic strain of K12. Proteins extracted from the organism grown in natural isotopic abundance minimal medium and also minimal medium containing isotopically labeled leucine (Leu-D10), were mixed and analyzed by capillary isoelectric focusing (CIEF) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR). The incorporation of the isotopically labeled Leu residue has no effect on the CIEF separation of the protein, therefore both versions of the protein are observed within the same FTICR spectrum. The difference in the molecular mass of the natural isotopic abundance and Leu-D10 isotopically labeled proteins is used to determine the number of Leu residues present in that particular protein. Knowledge of the molecular mass and number of Leu residues present can be used to unambiguously identify the intact protein. Preliminary results show the efficacy of this method for unambiguously identifying proteins isolated from E. coli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
“co-workers (17) have used fourier transform-ion cyclotron”
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Zhang, H., Li, X.-J., Martin, D. B., & Aebersold, R. (2003) · Nature Biotechnology · doi:10.1038/nbt827 · Cited by 1,389
Proteolytic 18O Labeling for Comparative Proteomics: Model Studies with Two Serotypes of Adenovirus
Yao, X., Freas, A., Ramirez, J., Demirev, P. A., & Fenselau, C. (2001) · Analytical Chemistry · doi:10.1021/ac001404c · Cited by 759
Quantitative, High-Resolution Proteomics for Data-Driven Systems Biology
Cox, J., & Mann, M. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061308-093216 · Cited by 685
Quantitative Proteomic Analysis by Accurate Mass Retention Time Pairs
Silva, J. C., Denny, R., Dorschel, C. A., Gorenstein, M., Kass, I. J., Li, G.-Z., McKenna, T., Nold, M. J., Richardson, K., Young, P., et al. (2005) · Analytical Chemistry · doi:10.1021/ac048455k · Cited by 639
Target profiling of small molecules by chemical proteomics
Rix, U., & Superti-Furga, G. (2009) · Nature Chemical Biology · doi:10.1038/nchembio.216 · Cited by 575
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Self-citationZhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Self-citationInterfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314
Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Quantitative proteomics using SILAC: Principles, applications, and developments
Chen, X., Wei, S., Ji, Y., Guo, X., & Yang, F. (2015) · PROTEOMICS · doi:10.1002/pmic.201500108 · Cited by 240
Controlling Deuterium Isotope Effects in Comparative Proteomics
Zhang, R., Sioma, C. S., Thompson, R. A., Xiong, L., & Regnier, F. E. (2002) · Analytical Chemistry · doi:10.1021/ac025614w · Cited by 238
Peptidomics: Identification and quantification of endogenous peptides in neuroendocrine tissues
Fricker, L. D., Lim, J., Pan, H., & Che, F. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20079 · Cited by 212
Amino acid residue specific stable isotope labeling for quantitative proteomics
Zhu, H., Pan, S., Gu, S., Bradbury, E. M., & Chen, X. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.831 · Cited by 211
Metabolic Labeling of Proteins for Proteomics
Beynon, R. J., & Pratt, J. M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r400010-mcp200 · Cited by 205
“(39) used incorporation of [(2)H10]leucine into Escherichia coli proteins and rapid separation by capillary isoelectric focusing.”
MethodCapillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Global internal standard technology for comparative proteomics
Chakraborty, A., & Regnier, F. E. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00047-x · Cited by 184
The Escherichia coli Proteome: Past, Present, and Future Prospects
Han, M.-J., & Lee, S. Y. (2006) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00036-05 · Cited by 179
Stable isotope-coded proteomic mass spectrometry
Goshe, M. B., & Smith, R. D. (2003) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00014-9 · Cited by 175
Self-citationYao, X., Afonso, C., & Fenselau, C. (2003) · Journal of Proteome Research · doi:10.1021/pr025572s · Cited by 168
Stutz, H. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410130 · Cited by 168
Quantitative Proteomics by Metabolic Labeling of Model Organisms
Gouw, J. W., Krijgsveld, J., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r900001-mcp200 · Cited by 151
Elucidating Proteoform Families from Proteoform Intact-Mass and Lysine-Count Measurements
Shortreed, M. R., Frey, B. L., Scalf, M., Knoener, R. A., Cesnik, A. J., & Smith, L. M. (2016) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b01090 · Cited by 58
Alarmins in chronic noncommunicable diseases: Atherosclerosis, diabetes and cancer
Boteanu, R. M., Suica, V. I., Uyy, E., Ivan, L., Dima, S. O., Popescu, I., Simionescu, M., & Antohe, F. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2016.11.006 · Cited by 38
Metadata
- Authors
- Veenstra, T. D., Martinović, S., Anderson, G. A., Paša-Tolić, L., & Smith, R. D.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-01-01
- Volume
- 11
- Issue
- 1
- Pages
- 78-82
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2003964437
- Cited by
- 142
- References
- 0
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.