Electrical nanogap devices for biosensing
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
For detecting substances that are invisible to the human eye or nose, and particularly those biomolecules, the devices must have very small feature sizes, be compact and provide a sufficient level of sensitivity, often to a small number of biomolecules that are just a few nanometres in size. Electrical nanogap devices for biosensing have emerged as a powerful technique for detecting very small quantities of biomolecules. The most charming feature of the devices is to directly transduce events of biomolecules specific binding into useful electrical signals such as resistance/impedance, capacitance/dielectric, or field-effect. Nanogap devices in electrical biosensing have become a busy area of research which is continually expanding. A wealth of research is available discussing planar and vertical nanogap devices for biosensing. Planar nanogap devices including label-free, gold nanoparticle-labeled, nanoparticles-enhanced, nanogapped gold particle film, and carbon nanotube nanogap devices as well as vertical nanogap devices with two and three terminals for biosensing are carefully reviewed. The aim of this paper is to provide an updated overview of the work in this field. In each part, we discuss the principles of operation of electrical biosensing and consider major strategies for enhancing their performance and/or key challenges and opportunities in current stages, and in their further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piner, R. D., Zhu, J., Xu, F., Hong, S., & Mirkin, C. A. (1999) · Science · doi:10.1126/science.283.5402.661 · Cited by 3,052
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Direct measurement of electrical transport through DNA molecules
Porath, D., Bezryadin, A., de Vries, S., & Dekker, C. (2000) · Nature · doi:10.1038/35001029 · Cited by 1,693
Characterization of DNA Probes Immobilized on Gold Surfaces
Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9719586 · Cited by 1,541
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
A reliable approach to charge-pumping measurements in MOS transistors
Groeseneken, G., Maes, H. E., Beltran, N., & De Keersmaecker, R. F. (1984) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1984.21472 · Cited by 1,355
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Bio-Bar-Code-Based DNA Detection with PCR-like Sensitivity
Nam, J.-M., Stoeva, S. I., & Mirkin, C. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049384+ · Cited by 744
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Self-citationCovalently Bridging Gaps in Single-Walled Carbon Nanotubes with Conducting Molecules
Guo, X., Small, J. P., Klare, J. E., Wang, Y., Purewal, M. S., Tam, I. W., Hong, B. H., Caldwell, R., Huang, L., O'Brien, S., et al. (2006) · Science · doi:10.1126/science.1120986 · Cited by 501
Cited by
Molecular-Scale Electronics: From Concept to Function
Xiang, D., Wang, X., Jia, C., Lee, T., & Guo, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00680 · Cited by 1,336
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Wang, X., Ding, B., Sun, G., Wang, M., & Yu, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.05.001 · Cited by 533
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Control the size and surface chemistry of graphene for the rising fluorescent materials
Zhu, S., Tang, S., Zhang, J., & Yang, B. (2012) · Chemical Communications · doi:10.1039/c2cc31201h · Cited by 424
Huang, X., Hu, N., Gao, R., Yu, Y., Wang, Y., Yang, Z., Siu-Wai Kong, E., Wei, H., & Zhang, Y. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm34340a · Cited by 348
Self-citationGraphene oxide-based transparent conductive films
Zheng, Q., Li, Z., Yang, J., & Kim, J.-K. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.03.004 · Cited by 313
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308
“A LOT OF RESEARCH interest has been shown in the area of field-effect transistor (FET)-based biosensors due to the advantages that they offer in terms of being compatible with the standard CMOS technology, miniaturization, costeffective mass production, and label-free detection process [1].”
MethodPerformance Assessment of A Novel Vertical Dielectrically Modulated TFET-Based Biosensor
Verma, M., Tirkey, S., Yadav, S., Sharma, D., & Yadav, D. S. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2732820 · Cited by 276
“THE field-effect transistor (FET)-based biosensors are very popular for label-free detection process and also compatible for the CMOS technology [1]–[4].”
MethodAdvances in Biosensors and Diagnostic Technologies Using Nanostructures and Nanomaterials
Welch, E. C., Powell, J. M., Clevinger, T. B., Fairman, A. E., & Shukla, A. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104126 · Cited by 240
Cote, L. J., Kim, J., Zhang, Z., Sun, C., & Huang, J. (2010) · Soft Matter · doi:10.1039/c0sm00667j · Cited by 223
Akhavan, O., Ghaderi, E., & Emamy, H. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm34330d · Cited by 220
Recent Advances and Progress in Development of the Field Effect Transistor Biosensor: A Review
Wadhera, T., Kakkar, D., Wadhwa, G., & Raj, B. (2019) · Journal of Electronic Materials · doi:10.1007/s11664-019-07705-6 · Cited by 210
Sub-10 nm fabrication: methods and applications
Chen, Y., Shu, Z., Zhang, S., Zeng, P., Liang, H., Zheng, M., & Duan, H. (2021) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ac087c · Cited by 208
Gudarzi, M. M., & Sharif, F. (2011) · Soft Matter · doi:10.1039/c0sm01311k · Cited by 205
Lian, Q., He, Z., He, Q., Luo, A., Yan, K., Zhang, D., Lu, X., & Zhou, X. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.032 · Cited by 186
Toimil-Molares, M. E. (2012) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.3.97 · Cited by 185
Graphene-based materials for flexible energy storage devices
Chen, K., Wang, Q., Niu, Z., & Chen, J. (2018) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2017.08.015 · Cited by 168
Song, S., Lee, J. U., Jeon, M. J., Kim, S., & Sim, S. J. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113864 · Cited by 88
Dwivedi, P., & Kranti, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2640192 · Cited by 87
Metadata
- Authors
- Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J.
- Venue
- Materials Today
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 13
- Issue
- 11
- Pages
- 28-41
- ISSN
- 1369-7021 (ISSN-L)
- OpenAlex
- W2136170082
- Cited by
- 326
- References
- 41
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.