Electrical nanogap devices for biosensing
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
For detecting substances that are invisible to the human eye or nose, and particularly those biomolecules, the devices must have very small feature sizes, be compact and provide a sufficient level of sensitivity, often to a small number of biomolecules that are just a few nanometres in size. Electrical nanogap devices for biosensing have emerged as a powerful technique for detecting very small quantities of biomolecules. The most charming feature of the devices is to directly transduce events of biomolecules specific binding into useful electrical signals such as resistance/impedance, capacitance/dielectric, or field-effect. Nanogap devices in electrical biosensing have become a busy area of research which is continually expanding. A wealth of research is available discussing planar and vertical nanogap devices for biosensing. Planar nanogap devices including label-free, gold nanoparticle-labeled, nanoparticles-enhanced, nanogapped gold particle film, and carbon nanotube nanogap devices as well as vertical nanogap devices with two and three terminals for biosensing are carefully reviewed. The aim of this paper is to provide an updated overview of the work in this field. In each part, we discuss the principles of operation of electrical biosensing and consider major strategies for enhancing their performance and/or key challenges and opportunities in current stages, and in their further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piner, R. D., Zhu, J., Xu, F., Hong, S., & Mirkin, C. A. (1999) · Science · doi:10.1126/science.283.5402.661 · Cited by 3,052
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Direct measurement of electrical transport through DNA molecules
Porath, D., Bezryadin, A., de Vries, S., & Dekker, C. (2000) · Nature · doi:10.1038/35001029 · Cited by 1,693
Characterization of DNA Probes Immobilized on Gold Surfaces
Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9719586 · Cited by 1,541
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
A reliable approach to charge-pumping measurements in MOS transistors
Groeseneken, G., Maes, H. E., Beltran, N., & De Keersmaecker, R. F. (1984) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1984.21472 · Cited by 1,355
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Bio-Bar-Code-Based DNA Detection with PCR-like Sensitivity
Nam, J.-M., Stoeva, S. I., & Mirkin, C. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049384+ · Cited by 744
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Self-citationCovalently Bridging Gaps in Single-Walled Carbon Nanotubes with Conducting Molecules
Guo, X., Small, J. P., Klare, J. E., Wang, Y., Purewal, M. S., Tam, I. W., Hong, B. H., Caldwell, R., Huang, L., O'Brien, S., et al. (2006) · Science · doi:10.1126/science.1120986 · Cited by 501
Insulating behavior for DNA molecules between nanoelectrodes at the 100 nm length scale
Storm, A. J., van Noort, J., de Vries, S., & Dekker, C. (2001) · Applied Physics Letters · doi:10.1063/1.1421086 · Cited by 428
Bakker, E. (2004) · Analytical Chemistry · doi:10.1021/ac049580z · Cited by 354
Conductivity of a single DNA duplex bridging a carbon nanotube gap
Guo, X., Gorodetsky, A. A., Hone, J., Barton, J. K., & Nuckolls, C. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.4 · Cited by 338
Reversible Switching in Molecular Electronic Devices
Whalley, A. C., Steigerwald, M. L., Guo, X., & Nuckolls, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073127y · Cited by 320
Nanotube electronics for radiofrequency applications
Rutherglen, C., Jain, D., & Burke, P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.355 · Cited by 315
Single electron transistor using a molecularly linked gold colloidal particle chain
Sato, T., Ahmed, H., Brown, D., & Johnson, B. F. G. (1997) · Journal of Applied Physics · doi:10.1063/1.365600 · Cited by 286
Li, T., Hu, W., & Zhu, D. (2010) · Advanced Materials · doi:10.1002/adma.200900864 · Cited by 269
Miniature Organic Transistors with Carbon Nanotubes as Quasi-One-Dimensional Electrodes
Qi, P., Javey, A., Rolandi, M., Wang, Q., Yenilmez, E., & Dai, H. (2004) · Journal of the American Chemical Society · doi:10.1021/ja045900k · Cited by 220
Detection of MicroRNAs Using Target-Guided Formation of Conducting Polymer Nanowires in Nanogaps
Fan, Y., Chen, X., Trigg, A. D., Tung, C.-H., Kong, J., & Gao, Z. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067477g · Cited by 219
Self-citationA Bio-Bar-Code Assay Based upon Dithiothreitol-Induced Oligonucleotide Release
Thaxton, C. S., Hill, H. D., Georganopoulou, D. G., Stoeva, S. I., & Mirkin, C. A. (2005) · Analytical Chemistry · doi:10.1021/ac0514265 · Cited by 175
Nanostructure-based electrical biosensors
Roy, S., & Gao, Z. (2009) · Nano Today · doi:10.1016/j.nantod.2009.06.003 · Cited by 174
Chung, S., Ginger, D. S., Morales, M. W., Zhang, Z., Chandrasekhar, V., Ratner, M. A., & Mirkin, C. A. (2005) · Small · doi:10.1002/smll.200400005 · Cited by 173
Novel Dielectric-Modulated Field-Effect Transistor for
(2008) · Cited by 172
Nanogap Field‐Effect Transistor Biosensors for Electrical Detection of Avian Influenza
Gu, B., Park, T. J., Ahn, J., Huang, X., Lee, S. Y., & Choi, Y. (2009) · Small · doi:10.1002/smll.200900450 · Cited by 134
Self-citationDirect Electrical Measurements on Single-Molecule Genomic DNA Using Single-Walled Carbon Nanotubes
Roy, S., Vedala, H., Roy, A. D., Kim, D., Doud, M. S., Mathee, K., Shin, H.-K., Shimamoto, N., Prasad, V., & Choi, W. (2007) · Nano Letters · doi:10.1021/nl0716451 · Cited by 122
Theoretical and experimental study towards a nanogap dielectric biosensor
Yi, M., Jeong, K., & Lee, L. P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.05.003 · Cited by 115
Kim, D. S., Park, J.-E., Shin, J.-K., Kim, P. K., Lim, G., & Shoji, S. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.01.018 · Cited by 107
Sakata, T., Kamahori, M., & Miyahara, Y. (2004) · Materials Science and Engineering C · doi:10.1016/j.msec.2004.08.042 · Cited by 102
Direct current electrical characterization of ds-DNA in nanogap junctions
Iqbal, S. M., Balasundaram, G., Ghosh, S., Bergstrom, D. E., & Bashir, R. (2005) · Applied Physics Letters · doi:10.1063/1.1900315 · Cited by 95
Sublithographic vertical gold nanogap for label-free electrical detection of protein-ligand binding
Jang, D.-Y., Kim, Y.-P., Kim, H.-S., Ko Park, S.-H., Choi, S.-Y., & Choi, Y.-K. (2007) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.2713403 · Cited by 74
Kinsella, J. M., & Ivanisevic, A. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.313 · Cited by 65
Nanogap biosensors for electrical and label-free detection of biomolecular interactions
Kim, S. K., Cho, H., Park, H.-J., Kwon, D., Lee, J. M., & Chung, B. H. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/45/455502 · Cited by 55
Electrical Detection of Oligonucleotide Using an Aggregate of Gold Nanoparticles as a Conductive Tag
Fang, C., Fan, Y., Kong, J., Gao, Z., & Balasubramanian, N. (2008) · Analytical Chemistry · doi:10.1021/ac801433z · Cited by 52
Polysaccharide Templated Silver Nanowire for Ultrasensitive Electrical Detection of Nucleic Acids
Kong, J., Ferhan, A. R., Chen, X., Zhang, L., & Balasubramanian, N. (2008) · Analytical Chemistry · doi:10.1021/ac800334y · Cited by 40
Self-citationNanogap capacitors: Sensitivity to sample permittivity changes
Ionescu‐Zanetti, C., Nevill, J. T., Carlo, D. D., Jeong, K., & Lee, L. P. (2006) · Journal of Applied Physics · doi:10.1063/1.2161818 · Cited by 37
Kim, S., Ahn, J., Park, T. J., Lee, S. Y., & Choi, Y. (2009) · Applied Physics Letters · doi:10.1063/1.3148340 · Cited by 34
Tsai, C.-Y., Chang, T.-L., Kuo, L.-S., & Chen, P. (2006) · Applied Physics Letters · doi:10.1063/1.2390653 · Cited by 13
Electrical signal amplification of DNA hybridization by nanoparticles in a nanoscale gap
Chen, C., Ko, F., Chen, C.-T., Liu, T.-F., Chang, E. Y., Yang, Y.-H., Yan, S.-J., & Chu, T.-C. (2007) · Applied Physics Letters · doi:10.1063/1.2825282 · Cited by 12
Electric detection of DNA hybridization by nanoparticle nanoswitch
Ah, C. S., Yun, Y. J., Park, H. J., Jung, S. K., Kim, W.-J., Ha, D. H., & Yun, W. S. (2006) · Current Applied Physics · doi:10.1016/j.cap.2006.01.030 · Cited by 10
Wang, C., Huang, J., Wang, J., Gu, C., Wang, J., Zhang, B., & Liu, J. (2008) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2008.11.008 · Cited by 10
Self-citationHybridization sensing by electrical enhancement with nanoparticles in nanogap
Chen, C., Ko, F., Chang, E. Y., Chang, F., & Kuo, S. (2008) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.3002489 · Cited by 5
Cited by
Molecular-Scale Electronics: From Concept to Function
Xiang, D., Wang, X., Jia, C., Lee, T., & Guo, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00680 · Cited by 1,336
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Wang, X., Ding, B., Sun, G., Wang, M., & Yu, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.05.001 · Cited by 533
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Control the size and surface chemistry of graphene for the rising fluorescent materials
Zhu, S., Tang, S., Zhang, J., & Yang, B. (2012) · Chemical Communications · doi:10.1039/c2cc31201h · Cited by 424
Metadata
- Authors
- Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J.
- Venue
- Materials Today
- Publisher
- Elsevier BV
- Published
- 2010-11
- Volume
- 13
- Issue
- 11
- Pages
- 28-41
- ISSN
- 1369-7021 (ISSN-L)
- OpenAlex
- W2136170082
- Cited by
- 326
- References
- 41
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.