Clinical virology in real time
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The ability to detect nucleic acids has had and still has a major impact on diagnostics in clinical virology. Both quantitative and qualitative techniques, whether signal or target amplification based systems, are currently used routinely in most if not all virology laboratories. Technological improvements, from automated sample isolation to real time amplification technology, have given the ability to develop and introduce systems for most viruses of clinical interest, and to obtain clinical relevant information needed for optimal antiviral treatment options. Both polymerase chain reaction (PCR) and nucleic acid sequence-based amplification (NASBA) can currently be used together with real time detection to generate results in a short turn-around time and to determine whether variants relevant for antiviral resistance are present. These new technologies enable the introduction of an individual patient disease management concept. Within our clinical setting, we have introduced this e.g. for quantitative detection of Epstein–Barr Virus (EBV) in T-dell depleted allogeneic stem cell transplant patients. This enabled us to develop models for pre-emptive anti B-cell immunotherapy for EBV reactivation, thereby effectively reducing not the incidence of EBV-lymphoproliferative disease but the virus related mortality. Furthermore, additional clinically relevant viruses can now easily be detected simultaneously. It also becomes more feasible to introduce molecular testing for those viruses that can easily be detected using classical virological methods, like culture techniques or antigen detection. Prospective studies are needed to evaluate the clinical importance of the additional positive samples detected. It should however be made clear that a complete exchange of technologies is unlikely to occur, and that some complementary technologies should stay operational enabling the discovery of new viruses. The implementation of these molecular diagnostic technologies furthermore warrants the use and introduction of standardized materials as well as participation in international quality control programs. Finally, the use of an internal control throughout the whole procedure not only ensures the accuracy of the results generated, but also is necessary to enable precise quantification of these results and to determine detection thresholds more accurately. Since so many targets do have clinical implications, laboratories might prefer to use universal internal controls before the in-house developed assays should be introduced in clinical virology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A newly discovered human pneumovirus isolated from young children with respiratory tract disease
van den Hoogen, B. G., de Jong, J. C., Groen, J., Kuiken, T., de Groot, R., Fouchier, R. A. M., & Osterhaus, A. D. M. E. (2001) · Nature Medicine · doi:10.1038/89098 · Cited by 2,186 · cited 1×
“There is of course still a need for virus culture, otherwise we will be unable to identify new viruses circulating, like the human metapneumovirus (van den Hoogen et al., 2001), but it is clear that a large transition from virus culture into molecular diagnostics is at hand.”
BackgroundMackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318 · cited 2×
“The implementation of nucleic acid technology into routine diagnostics has made a great step forward with the introduction of real time technologies, which makes the detection of amplified products relatively easy (Niesters, 2001; Mackay et al., 2002).”
Backgroundvan Esser, J. W. J., van der Holt, B., Meijer, E., Niesters, H. G. M., Trenschel, R., Thijsen, S. F. T., van Loon, A. M., Frassoni, F., Bacigalupo, A., Schaefer, U. W., et al. (2001) · Blood · doi:10.1182/blood.v98.4.972 · Cited by 373 · cited 1×
“A TaqMan based assay for the gene encoding the p143 BNRF protein has been developed and used to investigate the incidence of EBV reactivation and the development of EBV related PTLDs (Niesters et al., 2000; van Esser et al., 2001a,b, 2002).”
MethodSelf-citationDevelopment of a Real-Time Quantitative Assay for Detection of Epstein-Barr Virus
Niesters, H. G. M., van Esser, J., Fries, E., Wolthers, K. C., Cornelissen, J., & Osterhaus, A. D. M. E. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.712-715.2000 · Cited by 305 · cited 1×
“A TaqMan based assay for the gene encoding the p143 BNRF protein has been developed and used to investigate the incidence of EBV reactivation and the development of EBV related PTLDs (Niesters et al., 2000; van Esser et al., 2001a,b, 2002).”
MethodSelf-citationLamivudine resistance inimmunocompetent chronic hepatitis B
Honkoop, P., Niesters, H. G. M., de Man, R. A., et al. (1997) · Journal of Hepatology · doi:10.1016/s0168-8278(97)80476-x · Cited by 271 · cited 1×
“-thiacytidine}, close monitoring of patients has become increasingly important due to the occurrence of viral resistant strains, or the presence of flares after withdrawal from antiviral therapy (Honkoop et al., 1995, 1997).”
BackgroundSelf-citationSaldanha, J., Gerlich, W., Lelie, N., Dawson, P., Heermann, K., Heath, A., & The WHO Collaborative Study Group (2001) · Vox Sanguinis · doi:10.1046/j.1423-0410.2001.00003.x · Cited by 252 · cited 1×
“…of quantitative assays, mainly due to the fact that standardization is limited to a select number of blood borne viruses, like HIV-1, hepatitis B virus (HBV) and HCV, for which internationally accepted World Health Organization (WHO) standards are made available (Saldanha et al., 1999, 2001).”
BackgroundDiagnosis of Herpes Simplex Virus Infections in the Clinical Laboratory by LightCycler PCR
Espy, M. J., Uhl, J. R., Mitchell, P. S., Thorvilson, J. N., Svien, K. A., Wold, A. D., & Smith, T. F. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.795-799.2000 · Cited by 239 · cited 2×
“HSV types 1 and 2 (Espy et al., 2000).”
BackgroundStuyver, L., Wyseur, A., Rombout, A., Louwagie, J., Scarcez, T., Verhofstede, C., Rimland, D., Schinazi, R. F., & Rossau, R. (1997) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.41.2.284 · Cited by 234 · cited 1×
“Other technolo- gies as reverse hybridization (Stuyver et al., 1997, 2000; Pas et al., 2002) or restriction fragment length polymorphism (RFLP) analysis (Allen et al., 1999; Niesters et al., 2002) might be more suitable, but it should be clear that they are only successful if the sequence changes…”
BackgroundQuantitation of Viral Load Using Real-Time Amplification Techniques
Niesters, H. G. M. (2001) · Methods · doi:10.1006/meth.2001.1264 · Cited by 220 · cited 2×
“Numerous examples of detecting and quantification of viral targets have been published already and the list is growing rapidly (Niesters, 2001).”
BackgroundSelf-citationPas, S. D., Fries, E., De Man, R. A., Osterhaus, A. D. M. E., & Niesters, H. G. M. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.8.2897-2901.2000 · Cited by 203 · cited 1×
“Real time amplification is thus definitely the technology to use (Pas et al., 2000).”
MethodSelf-citation
Cited by
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Role of Cell Culture for Virus Detection in the Age of Technology
Leland, D. S., & Ginocchio, C. C. (2007) · Clinical Microbiology Reviews · doi:10.1128/cmr.00002-06 · Cited by 553
Verweij, J. J., Blangé, R. A., Templeton, K., Schinkel, J., Brienen, E. A. T., van Rooyen, M. A. A., van Lieshout, L., & Polderman, A. M. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.3.1220-1223.2004 · Cited by 412
A Laboratory-Developed TaqMan Array Card for Simultaneous Detection of 19 Enteropathogens
Liu, J., Gratz, J., Amour, C., Kibiki, G., Becker, S., Janaki, L., Verweij, J. J., Taniuchi, M., Sobuz, S. U., Haque, R., et al. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.02658-12 · Cited by 393
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Modified Vaccinia Virus Ankara Protects Macaques against Respiratory Challenge with Monkeypox Virus
Stittelaar, K. J., van Amerongen, G., Kondova, I., Kuiken, T., van Lavieren, R. F., Pistoor, F. H. M., Niesters, H. G. M., van Doornum, G., van der Zeijst, B. A. M., Mateo, L., et al. (2005) · Journal of Virology · doi:10.1128/jvi.79.12.7845-7851.2005 · Cited by 230
“for a loss of sample or inhibition, as described before (17).”
MethodSelf-citationUse of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Verweij, J. J., Brienen, E. A. T., Ziem, J., Yelifari, L., Polderman, A. M., & Van Lieshout, L. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.685 · Cited by 219
“In each sample, 10(3) PFU/mL phocin herpes virus 1 (PhHV-1) was added within the isolation lysis buffer to serve as an internal control.(24) PCR amplification and detection.”
MethodTaniuchi, M., Verweij, J. J., Noor, Z., Sobuz, S. U., Lieshout, L. V., Petri, W. A., Haque, R., & Houpt, E. R. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0461 · Cited by 201
Basuni, M., Muhi, J., Othman, N., Verweij, J. J., Ahmad, M., Miswan, N., Rahumatullah, A., Aziz, F. A., Zainudin, N. S., & Noordin, R. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0499 · Cited by 201
Hoffmann, B., Beer, M., Reid, S. M., Mertens, P., Oura, C. A. L., van Rijn, P. A., Slomka, M. J., Banks, J., Brown, I. H., Alexander, D. J., et al. (2009) · Veterinary Microbiology · doi:10.1016/j.vetmic.2009.04.034 · Cited by 197
Aberle, J. H., Aberle, S. W., Pracher, E., Hutter, H.-P., Kundi, M., & Popow-Kraupp, T. (2005) · Pediatric Infectious Disease Journal · doi:10.1097/01.inf.0000168741.59747.2d · Cited by 176
“Seal herpesvirus type 1 (kindly provided by Bert Niesters) was used as a heterologous internal control to exclude a failure of DNA extraction or amplification.(19) Intracellular Cytokine Analysis.”
MethodSensitive and specific detection of Salmonid alphavirus using real-time PCR (TaqMan®)
Hodneland, K., & Endresen, C. (2006) · Journal of Virological Methods · doi:10.1016/j.jviromet.2005.08.012 · Cited by 159
“The real-time PCR technology is now used commonly for detection and quantification of many viruses (Mackay et al., 2002; Niesters, 2001; Niesters, 2002), however the only piscine viruses where real-time PCR assays have been developed are piscine nodavirus (Starkey et al.”
MethodIgnatius, R., Gahutu, J. B., Klotz, C., Steininger, C., Shyirambere, C., Lyng, M., Musemakweri, A., Aebischer, T., Martus, P., Harms, G., et al. (2012) · PLoS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0001677 · Cited by 127
“Martin Schutten, Department of Virology, Erasmus MC, Rotterdam, The Netherlands, was added to the isolation lysis buffer to serve as an internal control for the extraction process [28].”
MethodSpecific and sensitive diagnosis of syphilis using a real-time PCR for Treponema pallidum
Koek, A. G., Bruisten, S. M., Dierdorp, M., van Dam, A. P., & Templeton, K. (2006) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2006.01566.x · Cited by 61
Metadata
- Authors
- Niesters, H. G. M.
- Venue
- Journal of Clinical Virology
- Publisher
- Elsevier BV
- Published
- 2002-12
- Volume
- 25
- Pages
- 3-12
- ISSN
- 1386-6532 (ISSN-L)
- OpenAlex
- W2127065841
- Cited by
- 245
- References
- 14
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.