Repeated blood–brain barrier opening with an implantable ultrasound device for delivery of albumin-bound paclitaxel in patients with recurrent glioblastoma: a phase 1 trial
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Low-intensity pulsed ultrasound with microbubbles (LIPU/MB) can be used to open the blood-brain barrier (BBB). We aimed to determine the safety and pharmacokinetics of LIPU/MB to enhance the delivery of albumin-bound paclitaxel (ABX) to the peri-tumoral brain of recurrent glioblastoma (GBM) patients. Methods: We conducted a dose-escalation phase 1 clinical trial (NCT04528680). Adults (>18 years old) with recurrent GBM, tumor diameter <70 mm, and Karnofsky-performance ≥70 were eligible. A nine-emitter ultrasound device was implanted into a skull-window after tumor resection. LIPU/MB with intravenous ABX infusion was performed every 3 weeks for up to 6 cycles. Six dose levels (40-260 mg/m2) were evaluated. We did pharmacokinetic analyses of LIPU/MB in a subgroup of patients from the current study, and a subgroup who received carboplatin as part of a similar trial (NCT03744026). The primary endpoint was dose-limiting toxicity (DLT). Safety was assessed in all treated patients (n=17). Analysis was performed as per protocol. BBB opening was investigated by pre and post-sonication MRI. Findings: 9 males and 8 females were enrolled between October 29th 2020 and February 21st 2022. Median follow-up was 11.89 months (IQR 11.12, 12.78). At a dose level of 260 mg/m2, grade 3 encephalopathy occurred in 1/12 patients (8%) during the first cycle (considered DLT), and on a second patient on cycle 2 (grade 2). In both cases, it resolved, and treatment continued at a lower ABX dose. Imaging analysis showed BBB opening in the brain regions targeted by LIPU/MB which diminished over the first 1 hr. after sonication. LIPU/MB led to increase in brain parenchymal concentrations of ABX by 3.7-times (non-sonicated brain mean [ABX] 0.0373 uM, 95% CI 0.0223 - 0.0625 uM vs. sonicated brain mean [ABX] 0.1386 uM, 95% CI 0.0828 – 0.2319 uM, p<0.0001) and of carboplatin by 5.9-times (non-sonicated brain mean [carboplatin] 0.9914 uM, 95% CI 0.5624 - 1.747 uM vs. sonicated brain mean [carboplatin] 5.878 uM, 95% CI 3.4622 - 9.98 uM, p=0.00012 on pharmacokinetic study done on a similar trial (NCT03744026). Interpretations: LIPU/MB using a skull-implantable ultrasound transiently opens the BBB allowing for safe, repeated penetration of cytotoxic drugs into the brain. This study has prompted a subsequent phase 2 study, which is ongoing. Funding: NIH/NCI 1R01CA245969-01A1, P50CA221747, and philanthropic support. In-kind support from Carthera and BMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gradishar, W. J., Tjulandin, S., Davidson, N., Shaw, H., Desai, N., Bhar, P., Hawkins, M., & O'Shaughnessy, J. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.04.937 · Cited by 2,153
Challenges to curing primary brain tumours
Aldape, K., Brindle, K. M., Chesler, L., Chopra, R., Gajjar, A., Gilbert, M. R., Gottardo, N., Gutmann, D. H., Hargrave, D., Holland, E. C., et al. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0177-5 · Cited by 959
Blood-brain barrier opening in Alzheimer’s disease using MR-guided focused ultrasound
Lipsman, N., Meng, Y., Bethune, A. J., Huang, Y., Lam, B., Masellis, M., Herrmann, N., Heyn, C., Aubert, I., Boutet, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04529-6 · Cited by 950
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757
Self-citationIbrahim, N. K., Desai, N. P., Legha, S. S., Soon‐Shiong, P., Theriault, R. L., Rivera, E., Esmaeli, B., Ring, S. E., Bedikian, A. Y., Hortobágyi, G. N., et al. (2002) · PubMed · Cited by 705
Mainprize, T., Lipsman, N., Huang, Y., Meng, Y., Bethune, A., Ironside, S., Heyn, C., Alkins, R., Trudeau, M., Sahgal, A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-36340-0 · Cited by 618
Abrahao, A., Meng, Y., Llinas, M., Huang, Y., Hamani, C., Mainprize, T., Aubert, I., Heyn, C., Black, S. E., Hynynen, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12426-9 · Cited by 476
Noninvasive hippocampal blood-brain barrier opening in Alzheimer's disease with focused ultrasound.
Rezai, A. R., Ranjan, M., D’Haese, P.-F., Haut, M. W., Carpenter, J., Najib, U., Mehta, R. I., Chazen, J. L., Zibly, Z., Yates, J. R., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2002571117 · Cited by 365
Idbaih, A., Canney, M., Belin, L., Desseaux, C., Vignot, A., Bouchoux, G., Asquier, N., Law-Ye, B., Leclercq, D., Bissery, A., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-3643 · Cited by 362
Self-citationMcDannold, N., Vykhodtseva, N., Raymond, S., Jolesz, F. A., & Hynynen, K. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.07.010 · Cited by 323
Blood-brain barrier opening with focused ultrasound in Parkinson’s disease dementia
Gasca-Salas, C., Fernández-Rodríguez, B., Pineda-Pardo, J. A., Rodríguez-Rojas, R., Obeso, I., Hernández-Fernández, F., del Álamo, M., Mata, D., Guida, P., Ordás-Bandera, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-21022-9 · Cited by 319
MR-guided focused ultrasound enhances delivery of trastuzumab to Her2-positive brain metastases
Meng, Y., Reilly, R. M., Pezo, R. C., Trudeau, M., Sahgal, A., Singnurkar, A., Perry, J., Myrehaug, S., Pople, C. B., Davidson, B., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abj4011 · Cited by 232
Choi, J. J., Wang, S., Tung, Y.-S., Morrison, B., & Konofagou, E. E. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.08.006 · Cited by 205
Marty, B., Larrat, B., Van Landeghem, M., Robic, C., Robert, P., Port, M., Le Bihan, D., Pernot, M., Tanter, M., Lethimonnier, F., et al. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.100 · Cited by 199
Zhang, D. Y., Dmello, C., Chen, L., Arrieta, V. A., Gonzalez-Buendia, E., Kane, J. R., Magnusson, L. P., Baran, A., James, C. D., Horbinski, C., et al. (2020) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-2182 · Cited by 176
Self-citationPark, J., Aryal, M., Vykhodtseva, N., Zhang, Y.-Z., & McDannold, N. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.10.011 · Cited by 162
Tissue concentration of systemically administered antineoplastic agents in human brain tumors
Pitz, M. W., Desai, A., Grossman, S. A., & Blakeley, J. O. (2011) · Journal of Neuro-Oncology · doi:10.1007/s11060-011-0564-y · Cited by 161
Recurrence Pattern Analysis of Primary Glioblastoma
Rapp, M., Baernreuther, J., Turowski, B., Steiger, H., Sabel, M., & Kamp, M. A. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.04.053 · Cited by 160
Park, S. H., Kim, M. J., Jung, H. H., Chang, W. S., Choi, H. S., Rachmilevitch, I., Zadicario, E., & Chang, J. W. (2021) · Journal of Neurosurgery · doi:10.3171/2019.10.jns192206 · Cited by 139
Chu, P.-C., Chai, W.-Y., Tsai, C.-H., Kang, S.-T., Yeh, C.-K., & Liu, H.-L. (2016) · Scientific Reports · doi:10.1038/srep33264 · Cited by 136
Paclitaxel (TAXOL®) concentrations in brain tumor tissue
Heimans, J. J., Vermorken, J. B., Wolbers, J. G., Eeltink, C., Meijer, O. W. M., TAPHOORN, M. J. B., & Beijnen, J. H. (1994) · Annals of Oncology · doi:10.1093/oxfordjournals.annonc.a058736 · Cited by 131
O'Reilly, M. A., Hough, O., & Hynynen, K. (2017) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.16.02005 · Cited by 95
A novel tool to analyze MRI recurrence patterns in glioblastoma
Wick, W., Stupp, R., Beule, A.-C., Bromberg, J. E. C., Wick, A., Ernemann, U., Platten, M., Marosi, C., Mason, W. P., van den Bent, M. J., et al. (2008) · Neuro-Oncology · doi:10.1215/15228517-2008-058 · Cited by 93
Self-citationSalvage chemotherapy with paclitaxel for recurrent primary brain tumors.
Chamberlain, M. C., & Kormanik, P. A. (1995) · Journal of Clinical Oncology · doi:10.1200/jco.1995.13.8.2066 · Cited by 80
Epelbaum, S., Burgos, N., Canney, M., Matthews, D., Houot, M., Santin, M. D., Desseaux, C., Bouchoux, G., Stroer, S., Martin, C., et al. (2022) · Alzheimer's Research & Therapy · doi:10.1186/s13195-022-00981-1 · Cited by 72
Self-citationAsquier, N., Bouchoux, G., Canney, M., Martin, C., Law-Ye, B., Leclercq, D., Chapelon, J.-Y., Lafon, C., Idbaih, A., & Carpentier, A. (2020) · Journal of Neurosurgery · doi:10.3171/2018.9.jns182001 · Cited by 50
Self-citationOvercoming the Blood–Brain Barrier with an Implantable Ultrasound Device
Sonabend, A. M., & Stupp, R. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-0932 · Cited by 25
Self-citationDmello, C., Sonabend, A., Arrieta, V. A., Zhang, D. Y., Kanojia, D., Chen, L., Gould, A., Zhang, J., Kang, S. J., Winter, J., et al. (2022) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-21-2563 · Cited by 16
Self-citation
Cited by
Weller, M., Wen, P. Y., Chang, S. M., Dirven, L., Lim, M., Monje, M., & Reifenberger, G. (2024) · Nature Reviews Disease Primers · doi:10.1038/s41572-024-00516-y · Cited by 592
Glioblastoma Therapy: Past, Present and Future
Obrador, E., Moreno-Murciano, P., Oriol-Caballo, M., López-Blanch, R., Pineda, B., Gutiérrez-Arroyo, J., Loras, A., Gonzalez-Bonet, L., Martinez-Cadenas, C., Estrela, J., et al. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25052529 · Cited by 271
Ultrasound-Based Micro-/Nanosystems for Biomedical Applications
Huang, H., Zheng, Y., Chang, M., Song, J., Xia, L., Wu, C., Jia, W., Ren, H., Feng, W., & Chen, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00009 · Cited by 183
Zhu, H., Allwin, C., Bassous, M. G., & Pouliopoulos, A. N. (2024) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04795-z · Cited by 75
Tanaka, M., Araujo, A. C., Valenti, V. E., Guiguer, E. L., Catharin, V. C. S., Gualhardi, C. M., de Souza Bastos Mazuqueli Pereira, E., de Alvares Goulart, R., de Argolo Haber, R. S., de Carvalho, A. C. A., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27052370 · Cited by 13
Metadata
- Authors
- Sonabend, A. M., Gould, A., Amidei, C., Ward, R., Schmidt, K. A., Zhang, D. Y., Gomez, C., Bebawy, J. F., Liu, B. P., Bouchoux, G., Desseaux, C., Helenowski, I. B., Lukas, R. V., Dixit, K., Kumthekar, P., Arrieta, V. A., Lesniak, M. S., Carpentier, A., Zhang, H., Muzzio, M., Canney, M., & Stupp, R.
- Venue
- The Lancet Oncology
- Publisher
- Elsevier BV
- Published
- 2023-05
- Volume
- 24
- Issue
- 5
- Pages
- 509-522
- ISSN
- 1470-2045 (ISSN-L)
- OpenAlex
- W4367673693
- Cited by
- 260
- References
- 28
- FWCI
- 19.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.