The DOI matches its Crossref record.
Raman Spectroscopy of Normal and Diseased Human Breast Tissues
Abstract
Raman spectra of histologically normal human breast biopsy samples were compared to those exhibiting infiltrating ductal carcinoma (IDC) or fibrocystic change. Experiments at 784 nm with CCD detectors reduced fluorescence interference and produced high SNR spectra with relatively low (10-200 mW) laser power. Sample to sample and patient to patient variation for normal specimens were less than 5% for the ratios of major Raman bands. The Raman spectra changed dramatically in diseased specimens, with much weaker lipid bands being evident. The spectrum of infiltrating ductal carcinoma samples is similar to that of human collagen. Differences between benign (fibrocystic) and malignant (IDC) lesions were smaller than those between normal and IDC specimens, but were still reproducible. Fiberoptic sampling through a hypodermic needle and with a remote probe were demonstrated. The possibility of rapid diagnosis with Raman spectroscopy is considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Fourier Transform Infrared (FTIR) Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & ur Rehman, D. I. (2008) · Applied Spectroscopy Reviews · doi:10.1080/05704920701829043 · Cited by 1,916
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Raman Spectroscopy of Biological Tissues
Talari, A. C. S., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.923902 · Cited by 739
Micro-Raman Spectroscopy Detects Individual Neoplastic and Normal Hematopoietic Cells
Chan, J. W., Taylor, D. S., Zwerdling, T., Lane, S. M., Ihara, K., & Huser, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.066761 · Cited by 679
Diagnosing breast cancer by using Raman spectroscopy
Haka, A. S., Shafer-Peltier, K. E., Fitzmaurice, M., Crowe, J., Dasari, R. R., & Feld, M. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501390102 · Cited by 630
Real-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats
Heien, M. L. A. V., Khan, A. S., Ariansen, J. L., Cheer, J. F., Phillips, P. E. M., Wassum, K. M., & Wightman, R. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504657102 · Cited by 482
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
FT-INFRARED AND FT-RAMAN SPECTROSCOPY IN BIOMEDICAL RESEARCH
Naumann, D. (2001) · Applied Spectroscopy Reviews · doi:10.1081/asr-100106157 · Cited by 463
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Applications of Raman spectroscopy in cancer diagnosis
Auner, G. W., Koya, S. K., Huang, C., Broadbent, B., Trexler, M., Auner, Z., Elias, A., Mehne, K. C., & Brusatori, M. A. (2018) · Cancer and Metastasis Reviews · doi:10.1007/s10555-018-9770-9 · Cited by 385
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Structure of Water, Proteins, and Lipids in Intact Human Skin, Hair, and Nail
Gniadecka, M., Nielsen, O. F., Christensen, D. H., & Wulf, H. C. (1998) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1998.00146.x · Cited by 351
Discriminating Basal Cell Carcinoma from its Surrounding Tissue by Raman Spectroscopy
Bakker Schut, T. C., Caspers, P. J., Puppels, G. J., Nijssen, A., Heule, F., Neumann, M. H. A., & Hayes, D. P. (2002) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2002.01807.x · Cited by 346
Raman Spectroscopy Detects Biochemical Changes Due to Proliferation in Mammalian Cell Cultures
Short, K. W., Carpenter, S., Freyer, J. P., & Mourant, J. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.103.038604 · Cited by 286
Medical applications of Raman spectroscopy: From proof of principle to clinical implementation
Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J. (2002) · Biopolymers · doi:10.1002/bip.10064 · Cited by 280
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Metadata
- Authors
- Frank, C. J., McCreery, R. L., & Redd, D. C. B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1995-03-01
- Volume
- 67
- Issue
- 5
- Pages
- 777-783
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2068837962
- Cited by
- 400
- References
- 0
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.