The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Abstract
Electrospray ionization produces multiply charged molecular ions for biomolecules with molecular weights in excess of 100,000. This allows mass spectrometers with limited mass-to-charge range to extend their molecular weight range by a factor equal to the number of charges. The maximum number of observed charges for peptides and smaller proteins correlates well with the number of basic amino acid residues (Arg, Lys, His), except for disulfide-containing molecules, such as lysozyme and bovine albumin. However, reduction of disulfide linkages with 1,4-dithiothreitol (Cleland's reagent) may allow the protein to be in an extended conformation and make "buried" basic residues available for protonation to yield higher charged molecular ions by the electrospray ionization process. For larger proteins reduction of disulfide bridges greatly increases the maximum charge state, but charging of basic amino acid residues remains less efficient than for smaller proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A NEW COUPLING COMPONENT FOR SULFANILAMIDE DETERMINATION
Bratton, A. C., & Marshall, E. K. (1939) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)73708-3 · Cited by 2,908
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Dithiothreitol, a New Protective Reagent for SH Groups*
Cleland, W. W. (1964) · Biochemistry · doi:10.1021/bi00892a002 · Cited by 1,992
Creighton, J. A., Blatchford, C. G., & Albrecht, M. G. (1979) · Journal of the Chemical Society, Faraday Transactions 2 · doi:10.1039/f29797500790 · Cited by 1,694
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Characteristic Raman frequencies of organic compounds
Dollish, F. R., Fateley, W. G., & Bentley, F. F. (1974) · Cited by 839
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Cited by
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Self-citationNew developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Self-citationProtein synthesis by native chemical ligation: Expanded scope by using straightforward methodology
Hackeng, T. M., Griffin, J. H., & Dawson, P. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10068 · Cited by 675
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Self-citationThe utility of ETD mass spectrometry in proteomic analysis
Mikesh, L. M., Ueberheide, B., Chi, A., Coon, J. J., Syka, J. E. P., Shabanowitz, J., & Hunt, D. F. (2006) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2006.10.003 · Cited by 535
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Self-citationProtein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Self-citationSmith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Self-citationSchnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Native vs Denatured: An in Depth Investigation of Charge State and Isotope Distributions
Kafader, J. O., Melani, R. D., Schachner, L. F., Ives, A. N., Patrie, S. M., Kelleher, N. L., & Compton, P. D. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00040 · Cited by 51
Larson, E. J., Zhu, Y., Wu, Z., Chen, B., Zhang, Z., Zhou, S., Han, L., Zhang, Q., & Ge, Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03152 · Cited by 21
Metadata
- Authors
- Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1990-04-01
- Volume
- 62
- Issue
- 7
- Pages
- 693-698
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2033210824
- Cited by
- 274
- References
- 32
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.