CoChat

A Disposable, Reagentless, Third-Generation Glucose Biosensor Based on Overoxidized Poly(pyrrole)/Tetrathiafulvalene− Tetracyanoquinodimethane Composite

Palmisano, Francesco, Zambonin, Pier Giorgio, Centonze, Diego, Quinto, Maurizio · 2002 · Analytical Chemistry
Cited by 117

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A disposable glucose biosensor based on glucose oxidase immobilized on tetrathiafulvalene-tetracyanoquinodimethane (ITF-TCNQ) conducting organic salt synthesized in situ onto an overoxidized poly(pyrrole) (PPy(ox).) film is described. The TIF-TCNQ crystals grow through the nonconducting polypyrrole film (ensuring electrical connection to the underlying Pt electrode) and emerge from the film forming a treelike structure. The PPy(ox) film prevents the interfering substances from reaching the electrode surface. The sensor behavior can be modeled by assuming a direct reoxidation of the enzyme at the surface of the TTF-TCNQ crystals. A heterogeneous rate constant around 10(-6) - 10(-7) cm s(-1) has been estimated. The biosensor is nearly oxygen- and interference-free and when integrated in a flow injection system displays a remarkable sensitivity (70 nA/mM) and stability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0258608

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Palmisano, F., Zambonin, P. G., Centonze, D., & Quinto, M.
Venue
Analytical Chemistry
Published
2002-10-31
Volume
74
Issue
23
Pages
5913-5918
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2071167084
Cited by
117
References
1
FWCI
3.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.