The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Advanced biosensors for glucose and insulin
Abstract
Diabetes mellitus is a chronic metabolic disorder lasting for the lifetime of a person. Glucose and insulin are the main indicators in the monitoring and control of this disease. Most often, various laboratory tests are used in the diagnosis and control of diabetes. Among them, the estimation of blood glucose concentration is one of the main diagnostic criteria. Proper control of the blood glucose level can delay, and to a greater extent, prevent complications. Thus, blood glucose monitoring is a requisite tool in the management of diabetes mellitus. Insulin plays a major role in glucose metabolism and its determination is of great value in the diagnosis and control of diabetes. An uncountable number of biosensors have been developed based on various mechanisms which will make sure a continuous glucose as well as insulin monitoring. Biosensors became the most sophisticated tool for the detection of glucose and insulin and they are of different types. Enzymatic, non-enzymatic, electrochemical, optical, non-invasive, and continuous monitoring biosensors are discussed in this review. In recent years, there is progress towards the development of nanobiosensors using various nanomaterials. Here, we have reviewed the fabrication, modification, and recent approaches associated with insulin and glucose biosensors for the treatment of diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Chaubey, A., & Malhotra, B. D. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00313-x · Cited by 777
Recent Advances in Biosensor Technology for Potential Applications – An Overview
Vigneshvar, S., Sudhakumari, C. C., Senthilkumaran, B., & Prakash, H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00011 · Cited by 674
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Frew, J. E., & Hill, H. A. O. (1987) · Analytical Chemistry · doi:10.1021/ac00142a001 · Cited by 252
Noninvasive glucose monitoring using saliva nano-biosensor
Zhang, W., Du, Y., & Wang, M. L. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.02.002 · Cited by 232
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129
Time‐dependent inactivation of immobilized glucose oxidase and catalase
Tse, P. H. S., & Gough, D. A. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260290607 · Cited by 95
Research works printed but not linked: 198
- Ahmad, 2010, A single ZnO nanofiber-based highly sensitive amperometric glucose biosensor, J. Phys. Chem. C, 114, 9308, 10.1021/jp102505g · DOI · Paper page
- Al-Sagur, 2018, A glucose biosensor based on novel Lutetium bis-phthalocyanine incorporated silica-polyaniline conducting nanobeads, Biosens. Bioelectron., 102, 637, 10.1016/j.bios.2017.12.004 · doi:10.1016/j.bios.2017.12.004
- Alvi, 2012, Highly efficient potentiometric glucose biosensor based on functionalized InN quantum dots, Appl. Phys. Lett., 101, 153110, 10.1063/1.4758701 · doi:10.1063/1.4758701
- Anderson, 2017, A highly sensitive nonenzymatic glucose biosensor based on the regulatory effect of glucose on electrochemical behaviors of colloidal silver nanoparticles on MoS2, Sensors, 17, 1807, 10.3390/s17081807 · DOI
- Atanasov, 1994, Biosensor for continuous glucose monitoring, Biotechnol. Bioeng., 43, 262, 10.1002/bit.260430310 · DOI
- Atchudan, 2019, An ultrasensitive photoelectrochemical biosensor for glucose based on bio-derived nitrogen-doped carbon sheets wrapped titanium dioxide nanoparticles, Biosens. Bioelectron., 126, 160, 10.1016/j.bios.2018.10.049 · DOI
- Bhalla, 2016, Introduction to biosensors, Essays Biochem., 60, 1, 10.1042/EBC20150001 · DOI · Paper page
- Bhattacharya, A., Jain, C., Rao, V.P., Banerjee, S., 2012. Gold coated ZnO nanorod biosensor for glucose detection. AIP Conf. Proc. 1447, 295–296. https://doi.org/10.1063/1.4709996. · doi:10.1063/1.4709996
- Cano, 2008, A new, third generation, PVC / TTF – TCNQ composite amperometric biosensor for glucose determination, J. Electroanal. Chem., 615, 69, 10.1016/j.jelechem.2007.11.032 · doi:10.1016/j.jelechem.2007.11.032
- Cass, 1984, Ferrocene-mediated enzyme electrode for amperometric determination of glucose, Anal. Chem., 56, 667, 10.1021/ac00268a018 · DOI · Paper page
- Cella, 2010, Single-walled carbon nanotube-based chemiresistive affinity biosensors for small molecules: ultrasensitive glucose detection, J. Am. Chem. Soc., 132, 5024, 10.1021/ja100503b · DOI · Paper page
- Centonze, 1997, Electrochemical immobilisation of enzymes on conducting organic salt electrodes: characterisation of an oxygen independent and interference-free glucose biosensor, J. Electroanal. Chem., 435, 103, 10.1016/S0022-0728(97)00294-5 · doi:10.1016/s0022-0728(97)00294-5
- Cetin, 2018, An amperometric glucose biosensor based on PEDOT nanofibers, RSC Adv., 8, 19724, 10.1039/C8RA01385C · doi:10.1039/c8ra01385c
- Chen, 2017, Current and emerging technology for continuous glucose monitoring, Sensors, 17, 182, 10.3390/s17010182 · DOI · Paper page
- Chhasatia, 2017, Non-invasive, in vitro analysis of islet insulin production enabled by an optical porous silicon biosensor, Biosens. Bioelectron., 91, 515, 10.1016/j.bios.2017.01.004 · DOI
- Cho, 1996, Electrochemical adsorption of glucose oxidase onto polypyrrole film for the construction of a glucose biosensor, Sens. Actuators B Chem., 30, 137, 10.1016/0925-4005(95)01756-L · doi:10.1016/0925-4005(95)01756-l
- Cho, 2019, Carbon-dot-based ratiometric fluorescence glucose biosensor, Sens. Actuators B: Chem., 282, 719, 10.1016/j.snb.2018.11.055 · DOI
- Chu, 2007, Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode, Talanta, 71, 2040, 10.1016/j.talanta.2006.09.013 · DOI · Paper page
- Chu, 2015, In-situ fabrication of well-distributed gold nanocubes on thiol graphene as a third-generation biosensor for ultrasensitive glucose detection, Electrochim. Acta, 176, 162, 10.1016/j.electacta.2015.06.123 · doi:10.1016/j.electacta.2015.06.123
- Clark, 1962, Electrode systems for continuous monitoring in cardiovascular surgery, Ann. N. Y. Acad. Sci., 102, 29, 10.1111/j.1749-6632.1962.tb13623.x · DOI · Paper page
- Claussen, 2010, Electrochemical glucose biosensor of platinum nanospheres connected by carbon nanotubes, J. Diabetes Sci. Technol., 4, 312, 10.1177/193229681000400211 · DOI
- Comba, 2018, Mucin and carbon nanotube-based biosensor for detection of glucose in human plasma, Anal. Biochem., 550, 34, 10.1016/j.ab.2018.04.006 · DOI
- Czajka, 1992, Scanning tunnelling microscopy study of polypymole films and of glucose oxidase as used in a third-generation biosensor, Bioelectrochem. Bioenerg., 29, 47, 10.1016/0302-4598(92)80052-I · doi:10.1016/0302-4598(92)80052-i
- D’Costa, 1986, Quinoprotein glucose dehydrogenase and its application in an amperometric glucose sensor, Biosensors, 2, 71, 10.1016/0265-928X(86)80011-6 · DOI · Paper page
- Dayakar, 2018, Novel synthesis and characterization of Ag@TiO2 core shell nanostructure for non-enzymatic glucose sensor, Appl. Surf. Sci., 435, 216, 10.1016/j.apsusc.2017.11.077 · doi:10.1016/j.apsusc.2017.11.077
- Ding, 2010, Electrospun Co3O4 nanofibers for sensitive and selective glucose detection, Biosens. Bioelectron., 26, 542, 10.1016/j.bios.2010.07.050 · DOI · Paper page
- Elsherif, 2018, Wearable contact lens biosensors for continuous glucose monitoring using smartphones, ACS Nano, 12, 5452, 10.1021/acsnano.8b00829 · DOI · Paper page
- Ensafi, 2017, Aptamer@Au-o-phenylenediamine modified pencil graphite electrode: a new selective electrochemical impedance biosensor for the determination of insulin, Colloids Surf. B Biointerfaces, 159, 47, 10.1016/j.colsurfb.2017.07.076 · doi:10.1016/j.colsurfb.2017.07.076
- Ertek, 2016, Photoelectrochemical glucose biosensor based on a dehydrogenase enzyme and NAD + /NADH redox couple using a quantum dot modified pencil graphite electrode, RSC Adv., 6, 20058, 10.1039/C5RA25673A · doi:10.1039/c5ra25673a
- F. Saiki, H. Ishizawa, A. Muro, E. Toba, Noninvasive measurement of blood glucose based on optical sensing and internal standard method, SICE Annual Conference 2007, Takamatsu, 2007, pp. 783–786. doi: https://doi.org/10.1109/SICE.2007.4421089. · doi:10.1109/sice.2007.4421089
- Fan, 1992, Permeability of glucose and other neutral species through recast perfluorosulfonated ionomer films, Anal. Chem., 64, 1304, 10.1021/ac00035a019 · DOI
- Fortier, 1992, Evaluation of nafion as media for glucose oxidase immobilization for the development of an amperometric glucose biosensor, Electroanalysis, 4, 275, 10.1002/elan.1140040304 · DOI
- Frasconi, 2010, Multifunctional Au nanoparticle dendrimer-based surface plasmon resonance biosensor and its application for improved insulin detection, Anal. Chem., 82, 7335, 10.1021/ac101319k · DOI
- Fulati, 2010, An intracellular glucose biosensor based on nanoflake ZnO, Sens. Actuators B Chem., 150, 673, 10.1016/j.snb.2010.08.021 · DOI
- Gerasimov, 2013, Development of an electrochemical insulin sensor based on the insulin-linked polymorphic region, Biosens. Bioelectron., 42, 62, 10.1016/j.bios.2012.10.046 · doi:10.1016/j.bios.2012.10.046
- German, 2010, Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles, Microchim. Acta, 168, 221, 10.1007/s00604-009-0270-z · DOI
- Goes, 1998, Morphological effect of the type, concentration and etching time of acid solutions on enamel and dentin surfaces, Braz. Dent. J., 9, 3
- Gough, 1985, Two dimensional enzyme electrode sensor for glucose, Anal. Chem., 57, 2351, 10.1021/ac00289a042 · DOI · Paper page
- Gualandi, 2019, Ni/Al layered double hydroxide and carbon nanomaterial composites for glucose sensing, ACS Appl. Nano Mater., 2, 143, 10.1021/acsanm.8b01765 · DOI
- Guilbault, 1973, An enzyme electrode for the amperometric determination of glucose, Anal. Chim. Acta, 64, 439, 10.1016/S0003-2670(01)82476-4 · DOI · Paper page
- Guo, 2018, Flexible and conductive titanium carbide–carbon nanofibers for high-performance glucose biosensing, Electrochim. Acta, 281, 517, 10.1016/j.electacta.2018.05.181 · doi:10.1016/j.electacta.2018.05.181
- Guo, 1999, Chemically derived prussian blue sol-gel composite thin films, Chem. Mater., 11, 135, 10.1021/cm9806275 · DOI
- Han, 2016, Genetically engineered phage-templated MnO2 nanowires: synthesis and their application in electrochemical glucose biosensor operated at neutral pH condition, ACS Appl. Mater. Interfaces, 8, 13768, 10.1021/acsami.6b03266 · doi:10.1021/acsami.6b03266
- Henry, 1998, Getting under the skin: implantable glucose sensors, Anal. Chem., 70, 594A, 10.1021/ac981937+ · DOI
- Hou, 2019, Ultrasensitive and highly flexible nonenzymatic glucose biosensor based on laser-scribed carbon paper substrate, Appl. Surf. Sci., 465, 320, 10.1016/j.apsusc.2018.09.166 · doi:10.1016/j.apsusc.2018.09.166
- Hovorka, 2013, Assessing performance of closed-loop insulin delivery systems by continuous glucose monitoring: drawbacks and way forward, Diabetes Technol. Ther., 15, 4, 10.1089/dia.2012.0185 · DOI
- Hrapovic, 2004, Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes, Anal. Chem., 76, 1083, 10.1021/ac035143t · DOI · Paper page
- Hu, 2014, Enzyme- labeled Pt@BSA nanocomposite as a facile electrochemical biosensing interface for sensitive glucose determination, ACS Appl. Mater. Interfaces, 6, 4170, 10.1021/am405841k · DOI
- Huang, 2010, Nanoelectronic biosensors based on CVD grown graphene, Nanoscale, 2, 1485, 10.1039/c0nr00142b · DOI · Paper page
- Hussain, 2011, Au-nanocluster emission based glucose sensing, Biosens. Bioelectron., 29, 60, 10.1016/j.bios.2011.07.066 · DOI
- Islam, 2011, A mediator free amperometric bienzymatic glucose biosensor using vertically aligned carbon nanofibers (VACNFs), IEEE Sens. J., 11, 2798, 10.1109/JSEN.2011.2169053 · DOI
- Jia, 2008, Carbon nanotubes based glucose needle-type biosensor, Sensors, 8, 1712, 10.3390/s8031712 · doi:10.3390/s8031712
- Jiang, 2010, A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode, Biosens. Bioelectron., 25, 1402, 10.1016/j.bios.2009.10.038 · DOI · Paper page
- Jung, 2018, Nonenzymatic flexible field-effect transistor based glucose sensor fabricated using NiO quantum dots modified ZnO nanorods, J. Colloid Interface Sci., 512, 21, 10.1016/j.jcis.2017.10.037 · doi:10.1016/j.jcis.2017.10.037
- Jung, 2009, Fabrication of self-assembled oligophenylethynylenethiol monolayer for electrochemical glucose biosensor, Ultramicroscopy, 109, 911, 10.1016/j.ultramic.2009.03.011 · doi:10.1016/j.ultramic.2009.03.011
- Kang, 2007, A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nanotube-modified glassy carbon electrode, Anal. Biochem., 363, 143, 10.1016/j.ab.2007.01.003 · DOI · Paper page
- Kang, 2009, Glucose Oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing, Biosens. Bioelectron., 25, 901, 10.1016/j.bios.2009.09.004 · DOI · Paper page
- Kartal, 2019, Molecularly imprinted polymer based quartz crystal microbalance sensor for the clinical detection of insulin, Mater. Sci. Eng.: C, 97, 730, 10.1016/j.msec.2018.12.086 · doi:10.1016/j.msec.2018.12.086
- Kaushik, 2008, Iron oxide nanoparticles-chitosan composite based glucose biosensor, Biosens. Bioelectron., 24, 676, 10.1016/j.bios.2008.06.032 · DOI · Paper page
- Kayakin, 1995, Prussian blue-based first-generation biosensor. A sensitive amperometric electrode for glucose, Anal. Chem., 67, 2419, 10.1021/ac00110a016 · DOI · Paper page
- Khadilkar, 2013, Current concepts in blood glucose monitoring, Indian J. Endocrinol. Metab., 17, S643, 10.4103/2230-8210.123556 · DOI
- Khan, 1996, Design of a stable charge transfer complex electrode for a third-generation amperometric glucose sensor, Anal. Chem., 68, 2939, 10.1021/ac9510393 · DOI
- Khodagholy, 2013, High transconductance organic electrochemical transistors, Nat. Commun., 4, 1, 10.1038/ncomms3133 · DOI · Paper page
- Kim, 2018, Wearable non-invasive epidermal glucose sensors: a review, Talanta, 177, 163, 10.1016/j.talanta.2017.08.077 · DOI · Paper page
- Kimmel, 2012, Electrochemical sensors and biosensors, Anal. Chem., 84, 685, 10.1021/ac202878q · DOI · Paper page
- Koncki, 1999, Composite films of Prussian blue and N-substituted polypyrroles: covalent immobilization of enzymes and application to near infrared optical biosensing, Biosens. Bioelectron., 14, 87, 10.1016/S0956-5663(98)00095-5 · DOI
- Kong, 2009, An amperometric glucose biosensor based on the immobilization of glucose oxidase on the ZnO nanotubes, Sens. Actuators B Chem., 138, 344, 10.1016/j.snb.2009.01.002 · DOI · Paper page
- Koopal, 1994, Highly stable first-generation biosensor for glucose utilizing latex particles as the enzyme-immobilizing matrix, Enzyme Microb. Technol., 402, 10.1016/0141-0229(94)90155-4 · DOI
- Koopal, 1993, Chronoamperometric detection of glucose by a third generation biosensor constructed from conducting microtubules of polypyrrole, Synth. Met., 57, 3689, 10.1016/0379-6779(93)90498-L · doi:10.1016/0379-6779(93)90498-l
- Koopal, 1994, Third-generation glucose biosensor incorporated in a conducting printing ink, Sens. Actuators B. Chem., 18, 166, 10.1016/0925-4005(94)87077-2 · doi:10.1016/0925-4005(94)87077-2
- Koopal, 1992, Third-generation amperometric biosensor for glucose. Polypyrrole deposited within a matrix of uniform latex particles as mediator, Bioelectrochem. Bioenerg., 29, 159, 10.1016/0302-4598(92)80064-N · doi:10.1016/0302-4598(92)80064-n
- Koskun, 2018, Highly sensitive glucose sensor based on monodisperse palladium nickel/activated carbon nanocomposites, Anal. Chim. Acta, 1010, 37, 10.1016/j.aca.2018.01.035 · DOI
- Kubo, 2015, Study on electrochemical insulin sensing utilizing a DNA aptamer-immobilized gold electrode, Materials, 8, 4710, 10.3390/ma8084710 · doi:10.3390/ma8084710
- Kwak, 2012, Flexible glucose sensor using CVD-grown graphene-based field effect transistor, Biosens. Bioelectron., 37, 82, 10.1016/j.bios.2012.04.042 · DOI · Paper page
- Lakowicz, 2006, Protein fluorescence spectroscopy, third edition
- Lenarczuk, 2001, Prussian blue-based optical glucose biosensor in flow-injection analysis, Anal. Chim. Acta, 447, 23, 10.1016/S0003-2670(01)01289-2 · DOI
- Li, 2009, Glucose biosensor based on nanocomposite films of CdTe quantum dots and glucose oxidase, Langmuir, 25, 6580, 10.1021/la900066z · DOI · Paper page
- Li, 2018, Dual-responsive electrochemical immunosensor for detection of insulin based on dual-functional zinc silicate spheres-palladium nanoparticles, Talanta, 179, 420, 10.1016/j.talanta.2017.11.037 · doi:10.1016/j.talanta.2017.11.037
- Lim, 2005, A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode, Biosens. Bioelectron., 20, 2341, 10.1016/j.bios.2004.08.005 · DOI · Paper page
- Lin, 2018, A flexible and highly sensitive nonenzymatic glucose sensor based on DVD-laser scribed graphene substrate, Biosens. Bioelectron., 110, 89, 10.1016/j.bios.2018.03.019 · DOI
- Lin, 2004, Glucose biosensors based on carbon nanotube nanoelectrode ensembles, Nano, 4, 191
- Liu, 2014, Electrochemical performance of electrospun free-standing nitrogen-doped carbon nanofibers and their application for glucose biosensing, ACS Appl. Mater. Interfaces, 6, 6275, 10.1021/am501713g · DOI
- Liu, 2001, A novel improved design for the first-generation glucose biosensor, Food Technol. Biotechnol., 39, 55
- Liu, 2018, NiCo2O4 nanoneedle-decorated electrospun carbon nanofiber nanohybrids for sensitive non-enzymatic glucose sensors, Sens. Actuators B: Chem., 258, 920, 10.1016/j.snb.2017.11.118 · doi:10.1016/j.snb.2017.11.118
- Liu, 2005, The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix, Biosens. Bioelectron., 21, 984, 10.1016/j.bios.2005.03.003 · DOI · Paper page
- Longchamp, 1998, Enhanced sensivity of a first generation glucose amperometric biosensor based on fibrinogen-precoating to carbon paste electrode, Electroanalysis, 10, 1064, 10.1002/(SICI)1521-4109(199810)10:15<1064::AID-ELAN1064>3.0.CO;2-L · doi:10.1002/(sici)1521-4109(199810)10:15<1064::aid-elan1064>3.0.co;2-l
- Lu, 2011, In situ synthesis of palladium nanoparticle-graphene nanohybrids and their application in nonenzymatic glucose biosensors, Biosens. Bioelectron., 26, 3500, 10.1016/j.bios.2011.01.033 · DOI · Paper page
- Luo, 2010, Amperometric glucose biosensor based on NiFe2O4nanoparticles and chitosan, Sens. Actuators B Chem., 145, 293, 10.1016/j.snb.2009.12.018 · DOI
- Luo, 2006, Application of nanoparticles in electrochemical sensors and biosensors, Electroanalysis, 18, 319, 10.1002/elan.200503415 · DOI · Paper page
- Luo, 2013, Ultrasensitive label free electrical detection of insulin in neat blood serum, Anal. Chem., 85, 4129, 10.1021/ac4002657 · DOI
- Ma, 2016, Sensitive insulin detection based on electrogenerated chemiluminescence resonance energy transfer between Ru(bpy)32+and Au nanoparticle-doped β-cyclodextrin-Pb (II) metal-organic framework, ACS Appl. Mater. Interfaces, 8, 10121, 10.1021/acsami.5b11991 · doi:10.1021/acsami.5b11991
- Ma, 2011, Recent advances and applications in QDs-based sensors, Analyst, 136, 4883, 10.1039/c1an15741h · DOI
- Mai, 2017, Non-enzymatic fluorescent biosensor for glucose sensing based on ZnO nanorods, J. Electron. Mater., 46, 3714, 10.1007/s11664-017-5300-8 · doi:10.1007/s11664-017-5300-8
- Mairal, 2008, Aptamers: molecular tools for analytical applications, Anal. Bioanal. Chem., 390, 989, 10.1007/s00216-007-1346-4 · DOI · Paper page
- Malhotra, 2017, Biosensors: principle, types and applications, Int. J. Adv. Res. Innovative Ideas Educ., 3, 3639
- Malitesta, 1990, Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) film, Anal. Chem., 62, 2735, 10.1021/ac00223a016 · DOI · Paper page
- Maniruzzaman, 2012, Titanium dioxide-cellulose hybrid nanocomposite and its glucose biosensor application, Mater. Sci. Eng. B Solid-State Mater. Adv. Technol., 177, 844, 10.1016/j.mseb.2012.04.003 · doi:10.1016/j.mseb.2012.04.003
- Marie, 2015, An electrochemical glucose sensor based on zinc oxide nanorods, Sensors, 15, 18714, 10.3390/s150818714 · doi:10.3390/s150818714
- Mayorga, 2011, Real-time measurement of glucose using chrono-impedance technique on a second generation biosensor, Biosens. Bioelectron., 29, 200, 10.1016/j.bios.2011.08.018 · DOI
- McCreery, 2008, Advanced carbon electrode materials for molecular electrochemistry, Chem. Rev., 108, 2646, 10.1021/cr068076m · DOI · Paper page
- Mehmeti, 2017, Wiring of glucose oxidase with graphene nanoribbons: an electrochemical third generation glucose biosensor, Microchim. Acta, 184, 1127, 10.1007/s00604-017-2115-5 · DOI
- Mehrotra, 2016, Biosensors and their applications – a review, J. Oral Biol. Craniofac. Res., 6, 153, 10.1016/j.jobcr.2015.12.002 · DOI · Paper page
- Meng, 2018, A novel electrochemical sensor for glucose detection based on Ag@ZIF-67 nanocomposite, Sens. Actuators B: Chem., 260, 852, 10.1016/j.snb.2018.01.109 · doi:10.1016/j.snb.2018.01.109
- Mohapatra, 2018, Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions, Appl. Surf. Sci., 442, 332, 10.1016/j.apsusc.2018.02.124 · DOI
- Moreno-Bondi, 2012, Biomimetic recognition elements for sensing applications, Anal. Bioanal. Chem., 402, 3019, 10.1007/s00216-012-5778-0 · doi:10.1007/s00216-012-5778-0
- Mosbach, 1974, An enzyme thermistor, Biochim. Biophys. Acta - Enzymol., 364, 140, 10.1016/0005-2744(74)90141-7 · doi:10.1016/0005-2744(74)90141-7
- Moussy, 1994, In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing, Anal. Chem., 66, 3882, 10.1021/ac00094a007 · DOI
- Murphy, 2006, Biosensors and bioelectrochemistry, Curr. Opin. Chem. Biol., 10, 177, 10.1016/j.cbpa.2006.02.023 · DOI · Paper page
- Ngamdee, 2018, Circular dichroism glucose biosensor based on chiral cadmium sulfide quantum dots, Sens. Actuators B: Chem., 274, 402, 10.1016/j.snb.2018.08.005 · DOI
- Niraj, 2012, Sensors for diabetes: glucose biosensors by using different newer techniques: a review, Int. J. Ther. Appl., 6, 28
- Palmisano, 2002, A disposable, reagentless, third-generation glucose biosensor based on overoxidized poly (pyrrole)/ tetrathiafulvalene - tetracyanoquinodimethane composite, Anal. Chem., 74, 5913, 10.1021/ac0258608 · DOI
- Palsaniya, 2019, Mixed surfactant mediated synthesis of hierarchical PANI nanorods for enzymatic glucose biosensor, ACS Appl. Polym. Mater., 10.1021/acsapm.8b00103 · DOI
- Patel, 2011, Flexible three-dimensional electrochemical glucose sensor with improved sensitivity realized in hybrid polymer microelectromechanical systems technique, J. Diabetes Sci. Technol., 5, 1036, 10.1177/193229681100500503 · DOI · Paper page
- Pauls, 2016, First generation amperometric glucose biosensor for determination of glucose at room temperature using glucose oxidase 38, Int. J. Pharm. Sci., 38, 102
- Pisoschi, 2012, Glucose determination by biosensors, Biochem. Anal. Biochem., 1, 1
- Pradhan, 2010, High-performance, flexible enzymatic glucose biosensor based on ZnO nanowires supported on a gold-coated polyester substrate, ACS Appl. Mater. Interfaces, 2, 2409, 10.1021/am100413u · DOI
- Punbusayakul, 2012, Carbon nanotubes architectures in electroanalysis, Procedia Eng., 32, 683, 10.1016/j.proeng.2012.01.1327 · doi:10.1016/j.proeng.2012.01.1327
- Rafighi, 2016, Fabrication of a third-generation glucose biosensor using graphene- polyethyleneimine-gold nanoparticles hybrid, Sens. Actuators B. Chem., 10.1016/j.snb.2016.03.147 · DOI
- Rahsepar, 2019, A new enzyme-free biosensor based on nitrogen-doped graphene with high sensing performance for electrochemical detection of glucose at biological pH value, Sens. Actuators B: Chem., 282, 322, 10.1016/j.snb.2018.11.078 · DOI
- Rakhi, 2016, Novel amperometric glucose biosensor based on MXene nanocomposite, Nat. Publ. Gr., 6, 1
- Reach, 1992, Can continuous glucose monitoring be used for the treatment of diabetes, Anal. Chem., 64, 381A
- Ridhuan, 2018, Fabrication and characterization of glucose biosensors by using hydrothermally grown ZnO nanorods, Sci. Rep., 8, 10.1038/s41598-018-32127-5 · doi:10.1038/s41598-018-32127-5
- Rodrıguez, 2001, Highly selective first generation glucose biosensor based on carbon paste containing copper and glucose oxidase, Electroanalysis, 13, 1179, 10.1002/1521-4109(200110)13:14<1179::AID-ELAN1179>3.0.CO;2-F · DOI
- Rosenthal, 2011, Biocompatible quantum dots for biological applications, Chem. Biol., 18, 10, 10.1016/j.chembiol.2010.11.013 · DOI · Paper page
- Ruiz-Valdepeñas Montiel, 2018, Direct electrochemical biosensing in gastrointestinal fluids, Anal. Bioanal. Chem., 1
- Sanghera, 2016, Insulin biosensor development: a case study, Int. J. Parallel Emergent Distrib. Syst., 32, 119, 10.1080/17445760.2016.1158817 · DOI
- Santhosh, 2009, Fabrication of enzymatic glucose biosensor based on palladium nanoparticles dispersed onto poly(3,4-ethylenedioxythiophene) nanofibers, Bioelectrochemistry, 75, 61, 10.1016/j.bioelechem.2008.12.001 · doi:10.1016/j.bioelechem.2008.12.001
- Sanz, 2007, Direct glucose determination in blood using a reagentless optical biosensor, Biosens. Bioelectron., 22, 2876, 10.1016/j.bios.2006.12.015 · doi:10.1016/j.bios.2006.12.015
- Saran, 2011, An optimized quantum dot-ligand system for biosensing applications: evaluation as a glucose biosensor, Colloids Surf. A Physicochem. Eng. Asp., 384, 393, 10.1016/j.colsurfa.2011.04.022 · doi:10.1016/j.colsurfa.2011.04.022
- Scheller, 2001, Research and development in biosensors, Curr. Opin. Biotechnol., 12, 35, 10.1016/S0958-1669(00)00169-5 · DOI · Paper page
- Scheller, 1991, Second generation biosensors, Biosens. Bioelectron., 6, 245, 10.1016/0956-5663(91)80010-U · doi:10.1016/0956-5663(91)80010-u
- Schonhoft, 2010, ILPR repeats adopt diverse G-quadruplex conformations that determine insulin binding, Biopolymers, 93, 21, 10.1002/bip.21289 · doi:10.1002/bip.21289
- Schubert, 2010, Quantum-dot-modified electrode in combination with NADH-dependent dehydrogenase reactions for substrate analysis, Langmuir, 26, 1395, 10.1021/la902499e · DOI
- Scognamiglio, 2013, Nanotechnology in glucose monitoring: advances and challenges in the last 10 years, Biosens. Bioelectron., 47, 12, 10.1016/j.bios.2013.02.043 · DOI · Paper page
- Senthamizhan, 2016, Glucose sensors based on electrospun nanofibers: a review Fiber-based Platforms for Bioanalytics, Anal. Bioanal. Chem., 408, 1285, 10.1007/s00216-015-9152-x · DOI
- Shan, 2010, Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing, Biosens. Bioelectron., 25, 1070, 10.1016/j.bios.2009.09.024 · DOI · Paper page
- Shao, 2010, Graphene based electrochemical sensors and biosensors: a review, Electroanalysis, 22, 1027, 10.1002/elan.200900571 · DOI · Paper page
- Shehab, 2016, Graphene quantum dots prepared from glucose as optical sensor for glucose, J. Lumin., 184, 110, 10.1016/j.jlumin.2016.12.006 · doi:10.1016/j.jlumin.2016.12.006
- Sheng, 2018, Ultrafast responsive and highly sensitive enzyme-free glucose sensor based on a novel Ni(OH)2@PEDOT-rGO nanocomposite, Sens. Actuators B: Chem., 254, 1206, 10.1016/j.snb.2017.08.008 · DOI
- Shi, 2006, Synthesis and application of quantum dots FRET-based protease sensors, J. Am. Chem. Soc., 128, 10378, 10.1021/ja063509o · DOI · Paper page
- Song, 2008, Aptamer-based biosensors, Trends Anal. Chem., 27, 108, 10.1016/j.trac.2007.12.004 · DOI · Paper page
- Steiner, 2011, Optical methods for sensing glucose, Chem. Soc. Rev., 40, 4805, 10.1039/c1cs15063d · DOI · Paper page
- Stern, 2010, Label-free biomarker detection from whole blood, Nat. Nanotechnol., 5, 138, 10.1038/nnano.2009.353 · DOI · Paper page
- Sternberg, 2015, Covalent enzyme coupling on cellulose acetate membranes for glucose sensor development, Anal. Chem., 60, 2781, 10.1021/ac00175a028 · DOI
- Taghdisi, 2015, Aptamer biosensor for selective and rapid determination of insulin, Anal. Lett., 48, 672, 10.1080/00032719.2014.956216 · doi:10.1080/00032719.2014.956216
- Taguchi, 2014, Nanomaterial-mediated biosensors for monitoring glucose, J. Diabetes Sci. Technol., 8, 403, 10.1177/1932296814522799 · DOI
- Thabit, 2012, Closed-loop insulin delivery in type 1 diabetes, Endocrinol. Metab. Clin. NA, 41, 105, 10.1016/j.ecl.2011.12.003 · DOI
- Thévenot, 2001, Electrochemical biosensors: recommended definitions and classification, Biosens. Bioelectron., 16, 121, 10.1016/S0956-5663(01)00115-4 · DOI · Paper page
- Tian, 2017, A sensitive electrochemiluminescence glucose biosensor based on graphene quantum dot prepared from graphene oxide sheets and hydrogen peroxide, J. Electroanal. Chem., 801, 162, 10.1016/j.jelechem.2017.07.019 · doi:10.1016/j.jelechem.2017.07.019
- Tsai, 2005, Cast thin film biosensor design based on a nafion backbone, a multiwalled carbon nanotube conduit, and a glucose oxidase function, Langmuir, 21, 3653, 10.1021/la0470535 · DOI · Paper page
- Turner, 1999, In vitro diagnostics in Diabetes: meeting the Challenge, Clin. Chem., 45, 1596, 10.1093/clinchem/45.9.1596 · DOI · Paper page
- Umar, 2006, Structural and optical properties of single-crystalline ZnO nanorods grown on silicon by thermal evaporation, Nanotechnology, 17, 4072, 10.1088/0957-4484/17/16/013 · doi:10.1088/0957-4484/17/16/013
- Updike, 1967, The enzyme electrode, Nature, 214, 986, 10.1038/214986a0 · DOI · Paper page
- Urgunde, 2018, Metal wire networks functionalized with nickel alkanethiolate based glucose biosensor, ACS Appl. Nano Mater., 1, 5571, 10.1021/acsanm.8b01115 · doi:10.1021/acsanm.8b01115
- Vamvakaki, 2006, Carbon nanofiber-based glucose biosensor, Anal. Chem., 78, 5538, 10.1021/ac060551t · DOI · Paper page
- Veiseh, 2014, Managing diabetes with nanomedicine: challenges and opportunities, Nat. Rev. Drug Discov., 14, 45, 10.1038/nrd4477 · DOI · Paper page
- Vukojević, 2018, Enzymatic glucose biosensor based on manganese dioxide nanoparticles decorated on graphene nanoribbons, J. Electroanal. Chem., 823, 610, 10.1016/j.jelechem.2018.07.013 · doi:10.1016/j.jelechem.2018.07.013
- Wang, 2009, A novel glucose biosensor based on the immobilization of glucose oxidase onto gold nanoparticles-modified Pb nanowires, Biosens. Bioelectron., 25, 142, 10.1016/j.bios.2009.06.022 · doi:10.1016/j.bios.2009.06.022
- Wang, 2001, Glucose biosensors: 40 years of advances and challenges, Electroanalysis, 13, 983, 10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# · DOI · Paper page
- Wang, 1998, Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions, J. Am. Chem. Soc., 120, 1048, 10.1021/ja972759p · DOI
- Wang, 2003, Enzyme-dispersed carbon-nanotube electrodes: a needle microsensor for monitoring glucose, Analyst, 128, 1382, 10.1039/b309928h · DOI
- Wang, 2003, Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors, J. Am. Chem. Soc., 125, 2408, 10.1021/ja028951v · DOI · Paper page
- Wang, 2013, Amperometric glucose biosensor based on silver nanowires and glucose oxidase, Sens. Actuators B. Chem., 176, 9, 10.1016/j.snb.2012.08.077 · doi:10.1016/j.snb.2012.08.077
- Wang, 2010, Fabrication of bienzymatic glucose biosensor based on novel gold nanoparticles-bacteria cellulose nanofibers nanocomposite, Electroanalysis, 22, 2543, 10.1002/elan.201000235 · doi:10.1002/elan.201000235
- Wang, 2018, Ultrasensitive photoelectrochemical immunosensor for insulin detection based on dual inhibition effect of CuS-SiO2 composite on CdS sensitized C-TiO2, Sens. Actuators B: Chem., 258, 1, 10.1016/j.snb.2017.11.073 · doi:10.1016/j.snb.2017.11.073
- Wang, 1992, Guanine residues in d(T2AG3) and d(T2G4) form parallel-stranded potassium cation stabilized G-quadruplexes with anti glycosidic torsion angles in solution, Biochemistry, 31, 8112, 10.1021/bi00150a002 · DOI · Paper page
- Wang, 2009, A carbon nanotubes assisted strategy for insulin detection and insulin proteolysis assay, Anal. Chim. Acta, 650, 49, 10.1016/j.aca.2009.02.029 · doi:10.1016/j.aca.2009.02.029
- Wei, 2010, ZnO nanorods/Au hybrid nanocomposites for glucose biosensor, Biosens. Bioelectron., 26, 275, 10.1016/j.bios.2010.06.006 · DOI
- Williamson, 1994, G-Quartet Structures in telomeric DNA, Annu. Rev. Biophys. Biomol. Sruct., 23, 703, 10.1146/annurev.bb.23.060194.003415 · DOI · Paper page
- Willner, 2007, Integrated nanoparticle-biomolecule systems for biosensing and bioelectronics, Biosens. Bioelectron., 22, 1841, 10.1016/j.bios.2006.09.018 · DOI · Paper page
- Wu, 2001, Bioassay of prostate-specific antigen (PSA) using microcantilevers, Nat. Biotechnol., 19, 856, 10.1038/nbt0901-856 · DOI · Paper page
- Wu, 2009, Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film, Talanta, 80, 403, 10.1016/j.talanta.2009.06.054 · DOI · Paper page
- Wu, 2006, Mediator-free amperometric determination of glucose based on direct electron transfer between glucose oxidase and an oxidized boron-doped diamond electrode, Anal. Bioanal. Chem., 385, 1330, 10.1007/s00216-006-0534-y · DOI
- Wu, 2010, Conjugation of glucose oxidase onto Mn-doped Zns quantum dots for phosphorescent sensing of glucose in biological fluids, Anal. Chem., 82, 1427, 10.1021/ac902531g · DOI · Paper page
- Wu, 2012, Specific glucose-to-SPR signal transduction at physiological pH by molecularly imprinted responsive hybrid microgels, Biomaterials, 33, 7115, 10.1016/j.biomaterials.2012.06.031 · DOI
- Wu, 2004, An optical glucose biosensor based on entrapped-glucose oxidase in silicate xerogel hybridised with hydroxyethyl carboxymethyl cellulose, Anal. Chim. Acta, 514, 219, 10.1016/j.aca.2004.03.052 · doi:10.1016/j.aca.2004.03.052
- Xiao, 2009, A genome-inspired DNA ligand for the affinity capture of insulin and insulin-like growth factor-2, J. Sep. Sci., 32, 1654, 10.1002/jssc.200900060 · DOI
- Xie, 1991, Rechargeable glucose electrodes for long-term implantation, J. Biomed. Eng., 13, 375, 10.1016/0141-5425(91)90017-2 · DOI
- Xu, 2013, The label free picomolar detection of insulin in blood serum, Biosens. Bioelectron., 39, 21, 10.1016/j.bios.2012.06.014 · DOI
- Yadav, 2014, Non Inavsive biosensor for diabetes monitoring, Asian J. Pharm. Clin. Res., 7, 206
- Yan, 2014, Solution-gated graphene transistors for chemical and biological sensors, Adv. Healthc. Mater., 3, 313, 10.1002/adhm.201300221 · DOI · Paper page
- Yang, 2003, Electrochemical reduction of a conjugated cinnamic acid diazonium salt as an immobilization matrix for glucose biosensor, Electroanalysis, 15, 885, 10.1002/elan.200390110 · DOI
- Yang, 2011, Glucose sensors based on electrodeposition of molecularly imprinted polymeric micelles: a novel strategy for MIP sensors, Biosens. Bioelectron., 26, 2607, 10.1016/j.bios.2010.11.015 · DOI
- Yin, 2018, A novel enzyme-free glucose and H2O2 sensor based on 3D graphene aerogels decorated with Ni3N nanoparticles, Anal. Chim. Acta, 1038, 11, 10.1016/j.aca.2018.06.086 · DOI
- Yue, 2013, Quantum-dot-based photoelectrochemical sensors for chemical and biological detection, ACS Appl. Mater. Interfaces, 5, 2800, 10.1021/am3028662 · DOI · Paper page
- Zhang, 2018, A novel electrochemiluminescent biosensor based on resonance energy transfer between poly(9,9-di-n-octylfluorenyl-2,7-diyl) and 3,4,9,10-perylenetetracarboxylic acid for insulin detection, Biosens. Bioelectron., 104, 65, 10.1016/j.bios.2017.12.046 · doi:10.1016/j.bios.2017.12.046
- Zhang, 2015, Aggregation-induced emission: a simple strategy to improve chemiluminescence resonance energy transfer, Anal. Chem., 87, 1351, 10.1021/ac5041605 · DOI
- Zhang, 2015, Highly sensitive glucose sensors based on enzyme-modified whole-graphene solution-gated transistors, Sci. Rep., 5, 1
- Zhang, 2005, Covalent attachment of glucose oxidase to an Au electrode modified with gold nanoparticles for use as glucose biosensor, Bioelectrochemistry, 67, 15, 10.1016/j.bioelechem.2004.12.002 · DOI · Paper page
- Zhang, 2004, Third-generation biosensors based on the direct electron transfer of proteins, Anal. Sci., 20, 603, 10.2116/analsci.20.603 · DOI · Paper page
- Zhang, 2009, Recent advances in nanotechnology applied to biosensors, Sensors, 9, 1033, 10.3390/s90201033 · DOI · Paper page
- Zhang, 1994, Elimination of the acetaminophen interference in an implantable glucose sensor, Anal. Chem., 66, 1183, 10.1021/ac00079a038 · DOI · Paper page
- Zhao, 2010, A nonenzymatic chemiluminescent reaction enabling chemiluminescence resonance energy transfer to qnantum dots, Chem. - Eur. J., 16, 6142, 10.1002/chem.201000478 · doi:10.1002/chem.201000478
- Zhao, 2010, ZnO-based amperometric enzyme biosensors, Sensors, 10, 1216, 10.3390/s100201216 · DOI · Paper page
- Zheng, 2013, Graphene versus multi-walled carbon nanotubes for electrochemical glucose biosensing, Materials, 6, 1011, 10.3390/ma6031011 · DOI
- Zhou, 2013, Development of a fast and sensitive glucose biosensor using iridium complex-doped electrospun optical fibrous membrane, Anal. Chem., 85, 1171, 10.1021/ac303107d · DOI
- Zhou, 2014, Aptamer-based biosensors for biomedical diagnostics, Analyst, 139, 2627, 10.1039/c4an00132j · DOI · Paper page
- Zhu, 2002, A novel flow through optical fiber biosensor for glucose based on luminol electrochemiluminescence, Sens. Actuators B Chem., 86, 209, 10.1016/S0925-4005(02)00173-9 · doi:10.1016/s0925-4005(02)00173-9
Cited by
Wearable health devices in health care: narrative systematic review
Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z. (2020) · JMIR mHealth and uHealth · doi:10.2196/18907 · Cited by 701
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
“Despite the chief motive of this review is to provide a multidisciplinary approach for a wide audience in the technical/clinical field, being a highly attractive area, a vast literature is witnessed by systematic readings that can be reached to deepen technological advancements on enzymatic, nonenzymatic, and optical…”
BackgroundRevisiting the Use of Biological Fluids for Noninvasive Glucose Detection
Zhao, M., & Leung, P. S. (2020) · Future Medicinal Chemistry · doi:10.4155/fmc-2020-0019 · Cited by 16
Metadata
- Authors
- Sabu, C., Henna, T. K., Raphey, V. R., Nivitha, K. P., & Pramod, K.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 141
- Pages
- 111201
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2923401654
- Cited by
- 221
- References
- 10
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advanced biosensors for glucose and insulin. https://app.cochat.ai/papers/10.1016/j.bios.2019.03.034
- The paper
- Sabu, C., Henna, T. K., Raphey, V. R., Nivitha, K. P., & Pramod, K. (2019). Advanced biosensors for glucose and insulin. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.03.034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.