Noninvasive Continuous Monitoring of Physiological Glucose Using a Monosaccharide-Sensing Contact Lens
Open accessThe DOI matches its Crossref record.
Abstract
We have tested the feasibility of tear glucose sensing using a daily, disposable contact lens embedded with boronic acid-containing fluorophores as a potential alternative to current invasive glucose-monitoring techniques. Our findings show that our approach may, indeed, be suitable for the continuous monitoring of tear glucose levels in the range 50-500 microM, which track blood glucose levels that are approximately 5-10-fold higher. We compare the response of the boronic acid probes in the contact lens to solution-based measurements and can conclude that both the pH and polarity within the contact lens need to be considered with respect to choosing/designing and optimizing glucose-sensing probes for contact lenses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
Adeel, M., Rahman, M. M., Caligiuri, I., Canzonieri, V., Rizzolio, F., & Daniele, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112331 · Cited by 327
Shi, W., Zhang, X., He, S., & Huang, Y. (2011) · Chemical Communications · doi:10.1039/c1cc14300j · Cited by 308
Advances in wearable chemical sensor design for monitoring biological fluids
Matzeu, G., Florea, L., & Diamond, D. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.01.077 · Cited by 300
Stretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat
Huang, X., Liu, Y., Chen, K., Shin, W., Lu, C., Kong, G., Patnaik, D., Lee, S., Cortes, J. F., & Rogers, J. A. (2014) · Small · doi:10.1002/smll.201400483 · Cited by 282
Lin, L., Song, X., Chen, Y., Rong, M., Zhao, T., Wang, Y., Jiang, Y., & Chen, X. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.024 · Cited by 280
Contact Lens Technology: From Fundamentals to Applications
Moreddu, R., Vigolo, D., & Yetisen, A. K. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900368 · Cited by 264
Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles
Jena, B. K., & Raj, C. R. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200501051 · Cited by 259
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Nanogold-plasmon-resonance-based glucose sensing
Aslan, K., Lakowicz, J. R., & Geddes, C. D. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.03.032 · Cited by 244
Self-citationGlucose Sensing with Phenylboronic Acid Functionalized Hydrogel-Based Optical Diffusers
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.7b07082 · Cited by 210
Stuart, D. A., Yonzon, C. R., Zhang, X., Lyandres, O., Shah, N. C., Glucksberg, M. R., Walsh, J. T., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac0501238 · Cited by 182
Glucose-Sensitive Holographic Sensors for Monitoring Bacterial Growth
Lee, M.-C., Kabilan, S., Hussain, A., Yang, X., Blyth, J., & Lowe, C. R. (2004) · Analytical Chemistry · doi:10.1021/ac049334n · Cited by 167
Tear Glucose Dynamics in Diabetes Mellitus
Lane, J. D., Krumholz, D. M., Sack, R. A., & Morris, C. (2006) · Current Eye Research · doi:10.1080/02713680600976552 · Cited by 161
A single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148
“Contact lens mounted biosensors have been developed to measure eye movement [4,5], tear glucose concentration [6–10], corneal temperature [11], blood oxygen [12], and intraocular pressure [13].”
BackgroundYang, X., Pan, X., Blyth, J., & Lowe, C. R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.09.016 · Cited by 103
Noninvasive Photonic-Crystal Material for Sensing Glucose in Tears
Khalil, O. S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.042978 · Cited by 30
Metadata
- Authors
- Badugu, R., Lakowicz, J. R., & Geddes, C. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-30
- Volume
- 76
- Issue
- 3
- Pages
- 610-618
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2094213149
- Cited by
- 151
- References
- 0
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.