The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
Abstract
A microfluidic device is reported that integrated cell handling, rapid cell lysis, and electrophoretic separation and detection of fluorescent cytosolic dyes. The device function was demonstrated using Jurkat cells that were loaded with the fluorogenic dyes - carboxyfluorescein diacetate, Oregon green carboxylic acid diacetate, or Calcein AM. The loaded cells were hydrodynamically transported from the cell-containing reservoir to a region on the microfluidic device where they were focused and then rapidly lysed using an electric field. Complete lysis was accomplished in <33 ms. The hydrolyzed, fluorescent dyes in the cell lysate were automatically injected into a separation channel on the device and detected 3 mm downstream of the injection point. The total separation time was approximately 2.2 s with absolute migration time reproducibilities of <1% and efficiencies ranging from 2300 to 4000 theoretical plates. Results from 139 cells are reported. A small fraction of these cells, approximately 9%, were found to enzymatically hydrolyze the loaded dyes in a manner significantly different from the majority of the cells. Cell analysis rates of 7-12 cells/min were demonstrated and are >100 times faster than those reported using standard bench-scale capillary electrophoresis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inositol trisphosphate and calcium signalling
Berridge, M. J. (1993) · Nature · doi:10.1038/361315a0 · Cited by 6,545
Dispersion of soluble matter in solvent flowing slowly through a tube
Taylor, G. I. (1953) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1953.0139 · Cited by 5,109
On the dispersion of a solute in a fluid flowing through a tube
Aris, R. (1956) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1956.0065 · Cited by 2,835
Calcium oscillations increase the efficiency and specificity of gene expression
Dolmetsch, R. E., Xu, K., & Lewis, R. S. (1998) · Nature · doi:10.1038/31960 · Cited by 1,893
Electroporation of cell membranes
Tsong, T. Y. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82054-9 · Cited by 1,094
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Self-citationGuide to Electroporation and Electrofusion
(1992) · Elsevier eBooks · doi:10.1016/c2009-0-21564-9 · Cited by 634
Probing Individual Molecules with Confocal Fluorescence Microscopy
Nie, S., Chiu, D. T., & Zare, R. N. (1994) · Science · doi:10.1126/science.7973650 · Cited by 549
An Integrated Microfabricated Cell Sorter
Fu, A. Y., Chou, H.-P., Spence, C., Arnold, F. H., & Quake, S. R. (2002) · Analytical Chemistry · doi:10.1021/ac0255330 · Cited by 510
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Microchip Device for Cell Lysis, Multiplex PCR Amplification, and Electrophoretic Sizing
Waters, L. C., Jacobson, S. C., Kroutchinina, N., Khandurina, J., Foote, R. S., & Ramsey, J. M. (1998) · Analytical Chemistry · doi:10.1021/ac970642d · Cited by 405
Self-citationMicrochip Device for Performing Enzyme Assays
Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac970192p · Cited by 383
Self-citationMiniaturized total analysis systems for biological analysis
Jakeway, S. C., de Mello, A. J., & Russell, E. L. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051548 · Cited by 324
Intracellular calcium dependence of gene expression in single T lymphocytes.
Negulescu, P. A., Shastri, N., & Cahalan, M. D. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.7.2873 · Cited by 244
Flow Cytometry of Escherichia coli on Microfluidic Devices
McClain, M. A., Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2001) · Analytical Chemistry · doi:10.1021/ac010504v · Cited by 224
Self-citationMicrofluidic Assays of Acetylcholinesterase Inhibitors
Hadd, A. G., Jacobson, S. C., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990591f · Cited by 193
Self-citationMicrochip Devices for High-Efficiency Separations
Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (2000) · Analytical Chemistry · doi:10.1021/ac0006268 · Cited by 185
Self-citationSubmillisecond detection of single rhodamine molecules in water
Mets, Ü., & Rigler, R. W. (1994) · Journal of Fluorescence · doi:10.1007/bf01878461 · Cited by 155
Electrochemical detection of histamine and 5-hydroxytryptamine at isolated mast cells
Pihel, K., Hsieh, S., Jorgenson, J. W., & Wightman, R. M. (1995) · Analytical Chemistry · doi:10.1021/ac00120a014 · Cited by 142
Measurement of kinase activation in single mammalian cells
Meredith, G. D., Sims, C. E., Soughayer, J. S., & Allbritton, N. L. (2000) · Nature Biotechnology · doi:10.1038/73760 · Cited by 132
Self-citationInstrumentation for Chemical Cytometry
Krylov, S. N., Starke, D. A., Arriaga, E. A., Zhang, Z., Chan, N. W. C., Palcic, M. M., & Dovic̀hi, N. J. (2000) · Analytical Chemistry · doi:10.1021/ac991096m · Cited by 117
Laser−Micropipet Combination for Single-Cell Analysis
Sims, C. E., Meredith, G. D., Krasieva, T. B., Berns, M. W., Tromberg, B. J., & Allbritton, N. L. (1998) · Analytical Chemistry · doi:10.1021/ac9802269 · Cited by 117
Self-citationChemical Analysis of Single Cells and Exocytosis
Chen, G., & Ewing, A. G. (1997) · Critical Reviews in Neurobiology · doi:10.1615/critrevneurobiol.v11.i1.40 · Cited by 83
Roddy, T. P., Cannon, D. M., Meserole, C. A., Winograd, N., & Ewing, A. G. (2002) · Analytical Chemistry · doi:10.1021/ac0255734 · Cited by 79
Single-Neuron Analysis Using CE Combined with MALDI MS and Radionuclide Detection
Page, J. S., Rubakhin, S. S., & Sweedler, J. V. (2002) · Analytical Chemistry · doi:10.1021/ac0156621 · Cited by 70
In-Situ Sampling and Separation of RNA from Individual Mammalian Cells
Han, F., & Lillard, S. J. (2000) · Analytical Chemistry · doi:10.1021/ac000428g · Cited by 69
Hsieh, S., Dreisewerd, K., van der Schors, R. C., Jiménez, C. R., Stahl-Zeng, J., Hillenkamp, F., Jorgenson, J. W., Geraerts, W. P. M., & Li, K. W. (1998) · Analytical Chemistry · doi:10.1021/ac9708295 · Cited by 57
Measurement of Single-Cell Gene Expression Using Capillary Electrophoresis
Zabzdyr, J. L., & Lillard, S. J. (2001) · Analytical Chemistry · doi:10.1021/ac0155714 · Cited by 47
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Metadata
- Authors
- McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-23
- Volume
- 75
- Issue
- 21
- Pages
- 5646-5655
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965621981
- Cited by
- 383
- References
- 29
- FWCI
- 21.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.