The DOI matches its Crossref record.
Aptamer-Based Sensor Arrays for the Detection and Quantitation of Proteins
Abstract
Aptamer biosensors have been immobilized on beads, introduced into micromachined chips on the electronic tongue sensor array, and used for the detection and quantitation of proteins. Aptamer chips could detect proteins in both capture and sandwich assay formats. Unlike most protein-based arrays, the aptamer chips could be stripped and reused multiple times. The aptamer chips proved to be useful for screening aptamers from in vitro selection experiments and for sensitively quantitating the biothreat agent ricin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
SELEX—A (r)evolutionary method to generate high-affinity nucleic acid ligands
Stoltenburg, R., Reinemann, C., & Strehlitz, B. (2007) · Biomolecular Engineering · doi:10.1016/j.bioeng.2007.06.001 · Cited by 1,430
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Functional Aptamers and Aptazymes in Biotechnology, Diagnostics, and Therapy
Famulok, M., Hartig, J. S., & Mayer, G. (2007) · Chemical Reviews · doi:10.1021/cr0306743 · Cited by 887
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Self-citationSynthetic genetic polymers capable of heredity and evolution
Pinheiro, V. B., Taylor, A. I., Cozens, C., Abramov, M., Renders, M., Zhang, S., Chaput, J. C., Wengel, J., Peak-Chew, S.-Y., McLaughlin, S. H., et al. (2012) · Science · doi:10.1126/science.1217622 · Cited by 730
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Aptamers as a replacement for antibodies in enzyme-linked immunosorbent assay
Toh, S. Y., Citartan, M., Gopinath, S. C. B., & Tang, T.-H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.026 · Cited by 612
The Chemical Biology of Aptamers
Mayer, G. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804643 · Cited by 592
Oligonucleotide Aptamers: New Tools for Targeted Cancer Therapy
Sun, H., Zhu, X., Lu, P. Y., Rosato, R. R., Tan, W., & Zu, Y. (2014) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2014.32 · Cited by 541
Aptamer-Conjugated Nanoparticles for Selective Collection and Detection of Cancer Cells
Herr, J. K., Smith, J. E., Medley, C. D., Shangguan, D., & Tan, W. (2006) · Analytical Chemistry · doi:10.1021/ac052015r · Cited by 431
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Nucleic acid aptamers and enzymes as sensors
Navani, N. K., & Li, Y. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.04.003 · Cited by 413
Sensor arrays for liquid sensing – electronic tongue systems
Ciosek, P., & Wróblewski, W. (2007) · The Analyst · doi:10.1039/b705107g · Cited by 408
Micromagnetic selection of aptamers in microfluidic channels
Lou, X., Qian, J., Xiao, Y., Viel, L., Gerdon, A. E., Lagally, E. T., Atzberger, P., Tarasow, T. M., Heeger, A. J., & Soh, H. T. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813135106 · Cited by 349
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
Surface immobilization methods for aptamer diagnostic applications
Balamurugan, S., Obubuafo, A., Soper, S. A., & Spivak, D. A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1587-2 · Cited by 312
Aptamers and the next generation of diagnostic reagents
Thiviyanathan, V., & Gorenstein, D. G. (2012) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201200042 · Cited by 275
Biosensor Recognition Elements
(2008) · Current Issues in Molecular Biology · doi:10.21775/cimb.010.001 · Cited by 264
Golub, E., Pelossof, G., Freeman, R., Zhang, H., & Willner, I. (2009) · Analytical Chemistry · doi:10.1021/ac901551q · Cited by 257
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Emerging affinity-based techniques in proteomics
Xie, S., Moya, C., Bilgin, B., Jayaraman, A., & Walton, S. P. (2009) · Expert Review of Proteomics · doi:10.1586/epr.09.74 · Cited by 38
Metadata
- Authors
- Kirby, R., Cho, E. J., Gehrke, B., Bayer, T., Park, Y. S., Neikirk, D. P., McDevitt, J. T., & Ellington, A. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-05-25
- Volume
- 76
- Issue
- 14
- Pages
- 4066-4075
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018483173
- Cited by
- 313
- References
- 0
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.