The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Aptamer-Modified Gold Nanoparticles for Colorimetric Determination of Platelet-Derived Growth Factors and Their Receptors
Abstract
We have developed a highly specific sensing system for platelet-derived growth factors (PDGFs) and platelet-derived growth factor receptors (PDGFR) that uses gold nanoparticles (GNPs). We synthesized GNPs modified with an aptamer (Apt-GNPs) that is specific to PDGFs and used them to detect PDGFs by monitoring the changes in the color and extinction of the Apt-GNPs that occur as a result of aggregation. The color of the Apt-GNPs changes from red to purple at low concentrations (<400 nM), but changes only slightly at higher concentrations (>400 nM). We found that the sensitivity of the Apt-GNPs for the three PDGFs is highly salt-dependent, with an optimum condition of 200 mM NaCl. We obtained biphasic curves when plotting of the ratios of the extinction coefficients of the Apt-GNPs at 650 and 530 nm against the concentrations of PDGF-AA at various concentrations of Apt-GNPs. The linear ranges of the increases and decreases in this extinction ratio are 2.5-10 and 10-20 nM, respectively, for 0.42 nM Apt-GNPs and 25-75 and 75-200 nM, respectively, for 8.4 nM Apt-GNPs. When using 8.4 nM Apt-GNPs, the corresponding linear ranges of the increases and decreases in this extinction ratio are 15-100 and 100-400 nM, respectively, for PDGF-AB and 35-150 and 150-400 nM, respectively, for PDGF-BB. In addition, we have developed a homogeneous assay to detect the PDGF receptor-beta (PDGFR-beta) at concentrations as low as 3.2 nM, on the basis of the competition between the Apt-GNPs and PDGFR-beta for PDGF-BB. The results we present in this paper imply that there are practical applications of Apt-GNPs in protein analysis and cancer diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kelly, K. L., Coronado, E., Zhao, L. L., & Schatz, G. C. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp026731y · Cited by 10,594
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
A DNA-based method for rationally assembling nanoparticles into macroscopic materials
Mirkin, C. A., Letsinger, R. L., Mucic, R. C., & Storhoff, J. J. (1996) · Nature · doi:10.1038/382607a0 · Cited by 6,683
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Surface Plasmon Spectroscopy of Nanosized Metal Particles
Mulvaney, P. (1996) · Langmuir · doi:10.1021/la9502711 · Cited by 3,681
Preparation and Characterization of Au Colloid Monolayers
Grabar, K. C., Freeman, R. G., Hommer, M. B., & Natan, M. J. (1995) · Analytical Chemistry · doi:10.1021/ac00100a008 · Cited by 2,756
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Ross, R., Glomset, J., Kariya, B., & Harker, L. (1974) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.71.4.1207 · Cited by 1,847
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Nanostructured Plasmonic Sensors
Stewart, M. E., Anderton, C. R., Thompson, L. B., Maria, J., Gray, S. K., Rogers, J. A., & Nuzzo, R. G. (2008) · Chemical Reviews · doi:10.1021/cr068126n · Cited by 2,415
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Self-citationTargeted polymeric therapeutic nanoparticles: design, development and clinical translation
Kamaly, N., Xiao, Z., Valencia, P. M., Radovic-Moreno, A. F., & Farokhzad, O. C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15344k · Cited by 1,730
Applications of Nanoparticles in Biology
De, M., Ghosh, P. S., & Rotello, V. M. (2008) · Advanced Materials · doi:10.1002/adma.200703183 · Cited by 1,547
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
Liu, J., & Lu, Y. (2006) · Nature Protocols · doi:10.1038/nprot.2006.38 · Cited by 1,126
Sepúlveda, B., Angelomé, P. C., Lechuga, L. M., & Liz-Marzán, L. M. (2009) · Nano Today · doi:10.1016/j.nantod.2009.04.001 · Cited by 1,023
Liu, J., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502589 · Cited by 956
Functional Aptamers and Aptazymes in Biotechnology, Diagnostics, and Therapy
Famulok, M., Hartig, J. S., & Mayer, G. (2007) · Chemical Reviews · doi:10.1021/cr0306743 · Cited by 887
Design of Gold Nanoparticle‐Based Colorimetric Biosensing Assays
Zhao, W., Brook, M. A., & Li, Y. (2008) · ChemBioChem · doi:10.1002/cbic.200800282 · Cited by 768
A Review on Functionalized Gold Nanoparticles for Biosensing Applications
Zeng, S., Yong, K.-T., Roy, I., Dinh, X.-Q., Yu, X., & Luan, F. (2011) · Plasmonics · doi:10.1007/s11468-011-9228-1 · Cited by 754
The use of gold nanoparticles in diagnostics and detection
Wilson, R. (2008) · Chemical Society Reviews · doi:10.1039/b712179m · Cited by 671
Colorimetric Biosensing Using Smart Materials
Song, Y., Wei, W., & Qu, X. (2011) · Advanced Materials · doi:10.1002/adma.201101853 · Cited by 666
Aptamers: molecular tools for analytical applications
Mairal, T., Cengiz Özalp, V., Lozano Sánchez, P., Mir, M., Katakis, I., & O’Sullivan, C. K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1346-4 · Cited by 587
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Jimmy Huang, P.-J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Silver Nanoparticle−Oligonucleotide Conjugates Based on DNA with Triple Cyclic Disulfide Moieties
Lee, J.-S., Lytton-Jean, A. K. R., Hurst, S. J., & Mirkin, C. A. (2007) · Nano Letters · doi:10.1021/nl071108g · Cited by 500
The Role Radius of Curvature Plays in Thiolated Oligonucleotide Loading on Gold Nanoparticles
Hill, H. D., Millstone, J. E., Banholzer, M. J., & Mirkin, C. A. (2009) · ACS Nano · doi:10.1021/nn800726e · Cited by 498
Targeted nanoparticles for cancer therapy
Gu, F. X., Karnik, R., Wang, A. Z., Alexis, F., Levy-Nissenbaum, E., Hong, S., Langer, R. S., & Farokhzad, O. C. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70083-x · Cited by 478
Wei, H., Li, B., Li, J., Wang, E., & Dong, S. (2007) · Chemical Communications · doi:10.1039/b707642h · Cited by 472
Alzheimer’s disease and its treatment by different approaches: A review
Srivastava, S., Ahmad, R., & Khare, S. K. (2021) · European Journal of Medicinal Chemistry · doi:10.1016/j.ejmech.2021.113320 · Cited by 467
Seok Kim, Y., Ahmad Raston, N. H., & Bock Gu, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.040 · Cited by 442
Biomedical Applications of Plasmon Resonant Metal Nanoparticles
Liao, H., Nehl, C. L., & Hafner, J. H. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.201 · Cited by 396
Wang, Z., & Ma, L. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2009.01.005 · Cited by 383
Control of enhanced Raman scattering using a DNA-based assembly process of dye-coded nanoparticles
Graham, D., Thompson, D. G., Smith, W. E., & Faulds, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.189 · Cited by 377
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C., Liu, H., Zou, Y., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905570 · Cited by 364
Self-citationRecent advances in transition-metal dichalcogenides based electrochemical biosensors: A review
Wang, Y.-H., Huang, K.-J., & Wu, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.06.011 · Cited by 358
Liu, J., Mazumdar, D., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603106 · Cited by 346
Xiang, Y., Tong, A., & Lu, Y. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905854a · Cited by 335
Qin, L., Zeng, G., Lai, C., Huang, D., Xu, P., Zhang, C., Cheng, M., Liu, X., Liu, S., Li, B., et al. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.01.006 · Cited by 332
Nucleic Acid Conjugated Nanomaterials for Enhanced Molecular Recognition
Wang, H., Yang, R., Yang, L., & Tan, W. (2009) · ACS Nano · doi:10.1021/nn9006303 · Cited by 329
Self-citationEnzyme Colorimetric Assay Using Unmodified Silver Nanoparticles
Wei, H., Chen, C., Han, B., & Wang, E. (2008) · Analytical Chemistry · doi:10.1021/ac801144t · Cited by 314
A Review of Gold and Silver Nanoparticle‐Based Colorimetric Sensing Assays
Sabela, M., Balme, S., Bechelany, M., Janot, J., & Bisetty, K. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700270 · Cited by 312
Surface immobilization methods for aptamer diagnostic applications
Balamurugan, S., Obubuafo, A., Soper, S. A., & Spivak, D. A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1587-2 · Cited by 312
Functional DNA nanotechnology: emerging applications of DNAzymes and aptamers
Lu, Y., & Liu, J. (2006) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.10.004 · Cited by 303
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Molecular diagnostic and drug delivery agents based on aptamer-nanomaterial conjugates
Lee, J. H., Yigit, M. V., Mazumdar, D., & Lu, Y. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.03.003 · Cited by 293
Biomolecule-nanoparticle hybrids for electrochemical biosensors
GUO, S., & DONG, S. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.10.014 · Cited by 274
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Nanotechnology and aptamers: applications in drug delivery
Levy-Nissenbaum, E., Radovic-Moreno, A. F., Wang, A. Z., Langer, R., & Farokhzad, O. C. (2008) · Trends in Biotechnology · doi:10.1016/j.tibtech.2008.04.006 · Cited by 270
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie · doi:10.1002/ange.200700269 · Cited by 265
Nanotechnology-Enhanced No-Wash Biosensors for in Vitro Diagnostics of Cancer
Huang, X., Liu, Y., Yung, B., Xiong, Y., & Chen, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b02618 · Cited by 259
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Dalirirad, S., & Steckl, A. J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.161 · Cited by 259
Colorimetric Detection of Heavy Metal Ions Using Label-Free Gold Nanoparticles and Alkanethiols
Hung, Y.-L., Hsiung, T.-M., Chen, Y.-Y., Huang, Y.-F., & Huang, C.-C. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp1061573 · Cited by 258
Self-citationAptamers: Active Targeting Ligands for Cancer Diagnosis and Therapy
Wu, X., Chen, J., Wu, M., & Zhao, J. X. (2015) · Theranostics · doi:10.7150/thno.10257 · Cited by 258
Menéndez-Manjón, A., Chichkov, B. N., & Barcikowski, S. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp909897v · Cited by 79
Metadata
- Authors
- Huang, C.-C., Huang, Y.-F., Cao, Z., Tan, W., & Chang, H.-T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-09
- Volume
- 77
- Issue
- 17
- Pages
- 5735-5741
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2042610830
- Cited by
- 542
- References
- 45
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.