Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

In Vivo Fluorescence Detection of Glucose Using a Single-Walled Carbon Nanotube Optical Sensor: Design, Fluorophore Properties, Advantages, and Disadvantages

Barone, Paul W., Parker, Robert S., Strano, Michael S.·2005·Analytical Chemistry

Abstract

In this work, several aspects of in vivo glucose detection using a nanotube-based optical sensor are considered. The optical properties of commonly used organic and nanoparticle fluorescent probes are compared with respect to quantum yield, human tissue penetration, and photobleaching stability. The latter two factors are shown to dominate sensor viability and require a near-infrared nanoparticle fluorophore for practical device operation. The dynamics of a model optical sensor are compared to a flux-measuring electrochemical sensor of equal area using a mathematical simulation of a healthy patient ingesting three predefined meals per day. Both sensors demonstrate an approximately linear response to blood glucose levels. It is shown that the optical sensor, which transduces glucose concentration, not flux, directly is significantly more stable to membrane biofouling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0511997

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

Metadata

Authors
Barone, P. W., Parker, R. S., & Strano, M. S.
Venue
Analytical Chemistry
Published
2005-11-02
Volume
77
Issue
23
Pages
7556-7562
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2041033069
Cited by
279
References
37
FWCI
9.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.