Cited by 65Polymer Surface Interaction StudiesAnalytical Chemistry and SensorsNitric Oxide and Endothelin Effects

Nitric oxide-releasing/generating polymers for the development of implantable chemical sensors with enhanced biocompatibility

Open access
Wu, Yiduo, Meyerhoff, Mark E.·2008·Talanta

Abstract

The development of reliable in vivo chemical sensors for real-time clinical monitoring of blood gases, electrolytes, glucose, etc. in critically ill and diabetic patients remains a great challenge owing to inherent biocompatibility problems that can cause errant analytical results upon sensor implantation (e.g., cell adhesion, thrombosis, inflammation). Nitric oxide (NO) is a well-known inhibitor of platelet activation and adhesion, and also a potent inhibitor of smooth muscle cell proliferation. In addition, NO mediates inflammatory response and promotes angiogenesis. Polymers that release or generate NO at their surfaces have been shown to exhibit greatly enhanced thromboresistance in vivo when in contact with flowing blood, as well as reduce inflammatory response when placed subcutaneously, and thus have the potential to improve the biocompatibility of implanted chemical sensors. Locally elevated NO levels at the surface of implanted devices can be achieved by using polymers that incorporate NO donor species that can decompose and release NO spontaneously when in contact with physiological fluids, or NO-generating polymers that possess an immobilized catalyst that decompose endogenous S-nitrosothiols to generate NO in situ. The potential use of such NO-releasing/generating materials for preparing in vivo sensors implanted either intravascularly or subcutaneously, is examined in this review.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2007.06.022

Cites

77 of 78 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Platelet adhesion and thrombus on sensor surfaces can isolate the sensing area, cause false analytical results, and increase emboli or stroke risk.

    “However, adhesion of platelets, and eventual thrombus formation on the surface of the sensors can occur within a few hours after blood contact, and such processes can not only isolate the chemical sensing area from the bulk of the blood and lead to false analytical results but also increase the risk of emboli or stroke.8,265”
  • Platelet adhesion and thrombus formation on intravascular sensor surfaces can occur within hours after blood contact.

    “However, adhesion of platelets, and eventual thrombus formation on the surface of the sensors can occur within a few hours after blood contact, and such processes can not only isolate the chemical sensing area from the bulk of the blood and lead to false analytical results but also increase the risk of emboli or stroke.8,265”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 20

  1. [1]Fogt E. Clin Chem. 1990;36:1573. [PubMed] [Google Scholar]
  2. [6]Williams D. Med Device Technol. 2003;14:10. [PubMed] [Google Scholar]
  3. [7]Meyerhoff ME. Trends Analyt Chem. 1993;12:257. [Google Scholar]
  4. [8]Andrade JD, Hlady V. Adv Polym Sci. 1986;79:1. [Google Scholar]
  5. [9]Colman RW. Cardiovasc Pathol. 1993;2:23. [Google Scholar]
  6. [12]Anderson JM. Cardiovasc Pathol. 1993;2:33. [Google Scholar]
  7. [23]Feldman PL, Griffith OW, Stuehr DJ. Chem Eng News. 1993;71:26. [Google Scholar]
  8. [25]Diodati JG, Quyyumi AA, Hussain N, Keefer LK. Thromb Haemost. 1993;70:654. [PubMed] [Google Scholar]
  9. [38]Gruetter CA, Barry BK, McNamara DB, Gruetter DY, Kadowitz PJ, Ignarro LJ. J Cyclic Nucleotide Res. 1979;5:211. [PubMed] [Google Scholar]
  10. [39]Massini P, Kaserglanzmann R, Luscher EF. Thromb Haemost. 1978;40:212. [PubMed] [Google Scholar]
  11. [42]Vaughn MW, Kuo L, Liao JC. Am J Physiol (Heart Circ Physiol) 1998;43:H2163. [Google Scholar]
  12. [43]Guzik TJ, Korbut R, Adamek-Guzik T. J Physiol Pharmacol. 2003;54:469. [PubMed] [Google Scholar]
  13. [49]Drago RS, Karstett Br. J Am Chem Soc. 1961;83:1819. [Google Scholar]
  14. [56]Espadas-Torre Oklejas V, Mowery K, Meyerhoff ME. J Am Chem Soc. 1997;119:2321. [Google Scholar]
  15. [57]Mowery KA, Schoenfisch MH, Baliga N, Wahr JA, Meyerhoff ME. Electroanalysis. 1999;11:681. [Google Scholar]
  16. [58]Frost MC, Batchelor MM, Lee YM, Zhang HP, Kang YJ, Oh BK, Wilson GS, Gifford R, Rudich SM, Meyerhoff ME. Microchem J. 2003;74:277. [Google Scholar]
  17. [67]Williams DLH. Acc Chem Res. 1999;32:869. [Google Scholar]
  18. [68]Holmes AJ, Williams DLH. J Chem Soc Perkin Trans. 2000;2:1639. [Google Scholar]
  19. [71]Hwang S, Meyerhoff ME. J Mater Chem. 2007 in submission. [Google Scholar]
  20. [79]Zhou ZR, Meyerhoff ME. Bio materials. 2005;26:6506. [Google Scholar]

Cited by

Sorted by citations

Authors
Wu, Y., & Meyerhoff, M. E.
Affiliations
University of Michigan (US)
Corresponding author
Meyerhoff, Mark E.
Venue
Talanta
Publisher
Elsevier BV
Published
2008-05-15
Volume
75
Issue
3
Pages
642-650
ISSN
0039-9140 (ISSN-L)
OpenAlex
W2064709994
Cited by
65
References
76
Citations by year
2026: 1 · 2025: 2 · 2024: 4 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 1 · 2017: 3 · 2016: 5 · 2015: 4 · 2014: 4 · 2013: 6 · 2012: 6
FWCI
1.28
Type
journal article
Language
en
Open access
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Biomedical Imaging and Bioengineering (R01EB000783)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Health Sciences › Medicine › Physiology › Nitric Oxide and Endothelin Effects
Keywords
nitric oxide, biocompatibility, thromboresistance, anti-inflammatory response, antiplatelet activity, blood gas monitoring, glucose monitoring, electrolyte monitoring
MeSH terms
Biocompatible Materials, Humans, Monitoring, Physiologic, Nitric Oxide, Polymers, Biosensing Techniques, Infusion Pumps, Implantable

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review