The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
In Vivo Fluorescence Detection of Glucose Using a Single-Walled Carbon Nanotube Optical Sensor: Design, Fluorophore Properties, Advantages, and Disadvantages
Abstract
In this work, several aspects of in vivo glucose detection using a nanotube-based optical sensor are considered. The optical properties of commonly used organic and nanoparticle fluorescent probes are compared with respect to quantum yield, human tissue penetration, and photobleaching stability. The latter two factors are shown to dominate sensor viability and require a near-infrared nanoparticle fluorophore for practical device operation. The dynamics of a model optical sensor are compared to a flux-measuring electrochemical sensor of equal area using a mathematical simulation of a healthy patient ingesting three predefined meals per day. Both sensors demonstrate an approximately linear response to blood glucose levels. It is shown that the optical sensor, which transduces glucose concentration, not flux, directly is significantly more stable to membrane biofouling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Physical Properties of Carbon Nanotubes
Saito, R., Dresselhaus, G., & Dresselhaus, M. S. (1998) · IMPERIAL COLLEGE PRESS eBooks · doi:10.1142/9781860943799 · Cited by 4,808
Band Gap Fluorescence from Individual Single-Walled Carbon Nanotubes
O'Connell, M. J., Bachilo, S. M., Huffman, C. B., Moore, V. C., Strano, M. S., Haroz, E. H., Rialon, K. L., Boul, P. J., Noon, W. H., Kittrell, C., et al. (2002) · Science · doi:10.1126/science.1072631 · Cited by 3,879
Self-citationStructure-Assigned Optical Spectra of Single-Walled Carbon Nanotubes
Bachilo, S. M., Strano, M. S., Kittrell, C., Hauge, R. H., Smalley, R. E., & Weisman, R. B. (2002) · Science · doi:10.1126/science.1078727 · Cited by 3,078
Self-citationBergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640
Extraordinary Mobility in Semiconducting Carbon Nanotubes
Dürkop, T., Getty, S. A., Cobas, E., & Fuhrer, M. S. (2004) · Nano Letters · doi:10.1021/nl034841q · Cited by 1,588
Near-infrared optical sensors based on single-walled carbon nanotubes
Barone, P. W., Baik, S., Heller, D. A., & Strano, M. S. (2005) · Nature Materials · doi:10.1038/nmat1276 · Cited by 987
Self-citationWray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Cyanine dye labeling reagents: Sulfoindocyanine succinimidyl esters
Mujumdar, R. B., Ernst, L. A., Mujumdar, S. R., Lewis, C. J., & Waggoner, A. S. (1993) · Bioconjugate Chemistry · doi:10.1021/bc00020a001 · Cited by 884
Near-Infrared Fluorescence Microscopy of Single-Walled Carbon Nanotubes in Phagocytic Cells
Cherukuri, P., Bachilo, S. M., Litovsky, S. H., & Weisman, R. B. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0466311 · Cited by 817
Solvent Dependence of the Fluorescence Lifetimes of Xanthene Dyes
Magde, D., Rojas, G. E., & Seybold, P. G. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb08277.x · Cited by 516
Increase in the Asian Southwest Monsoon During the Past Four Centuries
Anderson, D. M., Overpeck, J. T., & Gupta, A. K. (2002) · Science · doi:10.1126/science.1072881 · Cited by 515
Microporous and Photoluminescent Chalcogenide Zeolite Analogs
Zheng, N., Bu, X., Wang, B., & Feng, P. (2002) · Science · doi:10.1126/science.1078663 · Cited by 494
In situ forming degradable networks and their application in tissue engineering and drug delivery
Anseth, K. S., Metters, A. T., Bryant, S. J., Martens, P. J., Elisseeff, J. H., & Bowman, C. N. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00500-4 · Cited by 479
Fluorescence properties of indocyanine green as related to angiography
Benson, R. C., & Kues, H. A. (1978) · Physics in Medicine & Biology · doi:10.1088/0031-9155/23/1/017 · Cited by 432
(1985) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 417
Simultaneous Fluorescence and Raman Scattering from Single Carbon Nanotubes
Hartschuh, A., Pedrosa, H. N., Novotny, L., & Krauss, T. D. (2003) · Science · doi:10.1126/science.1087118 · Cited by 414
Degradation Kinetics of Indocyanine Green in Aqueous Solution
Saxena, V., Sadoqi, M., & Shao, J. (2003) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.10470 · Cited by 372
Schultz, J. S., Mansouri, S., & Goldstein, I. J. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.245 · Cited by 305
Elisseeff, J., McIntosh, W., Fu, K., Blunk, T., & Langer, R. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00054-7 · Cited by 296
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
A Fluorescence Affinity Hollow Fiber Sensor for Continuous Transdermal Glucose Monitoring
Ballerstadt, R., & Schultz, J. S. (2000) · Analytical Chemistry · doi:10.1021/ac000215r · Cited by 192
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154
Schmidtke, D. W., Freeland, A. C., Heller, A., & Bonnecaze, R. T. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.1.294 · Cited by 120
Norton, L. W., Tegnell, E., Toporek, S. S., & Reichert, W. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.069 · Cited by 106
Ballerstädt, R., Polak, A., Beuhler, A. J., & Frye, J. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.019 · Cited by 101
McCartney, L. J., Pickup, J. C., Rolinski, O. J., & Birch, D. J. S. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5060 · Cited by 94
[Measuring EEG complexity for studying the state of mental load].
Liu, J., He, T., Zheng, C., & Huang, Y. (1997) · PubMed · Cited by 92
Klueh, U., Dorsky, D. I., & Kreutzer, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.017 · Cited by 87
Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?
Rebrin, K., Fischer, U., von Dorsche, H. H., von Woetke, T., Abel, P., & Brunstein, E. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90033-h · Cited by 81
Pentosan Polysulfate as an Inhibitor of Extracellular HIV-1 Tat
Rusnati, M., Urbinati, C., Caputo, A., Possati, L., Lortat‐Jacob, H., Giacca, M., Ribatti, D., & Presta, M. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m010779200 · Cited by 75
Low-cost optical instrumentation for biomedical measurements
Kostov, Y. V., & Rao, G. (2000) · Review of Scientific Instruments · doi:10.1063/1.1319859 · Cited by 71
Current Problems and Potential Techniques in In Vivo Glucose Monitoring
Wickramasinghe, Y., Yang, Y., & Spencer, S. A. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039339.36839.19 · Cited by 63
Galeska, I., Hickey, T., Moussy, F. G., Kreutzer, D. L., & Papadimitrakopoulos, F. (2001) · Biomacromolecules · doi:10.1021/bm010112y · Cited by 62
A time-resolved near-infrared fluorescence assay for glucose: opportunities for trans-dermal sensing
Rolinski, O. J., Birch, D. J. S., McCartney, L. J., & Pickup, J. C. (2000) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/s1011-1344(99)00148-7 · Cited by 39
Histologic evaluation of the inflammatory response around implanted hollow fiber membranes
Clark, H., Barbari, T. A., Stump, K., & Rao, G. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<183::aid-jbm24>3.0.co;2-d · Cited by 37
Advances and prospects in glucose assay technology
Gough, D. A., Armour, J. C., & Baker, D. A. (1997) · Diabetologia · doi:10.1007/s001250051418 · Cited by 33
Cited by
Carbon nanotubes in biology and medicine: In vitro and in vivo detection, imaging and drug delivery
Liu, Z., Tabakman, S., Welsher, K., & Dai, H. (2009) · Nano Research · doi:10.1007/s12274-009-9009-8 · Cited by 1,716
Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Managing diabetes with nanomedicine: challenges and opportunities
Veiseh, O., Tang, B. C., Whitehead, K. A., Anderson, D. G., & Langer, R. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4477 · Cited by 613
Sgobba, V., & Guldi, D. M. (2009) · Chem. Soc. Rev. · doi:10.1039/b802652c · Cited by 536
Metadata
- Authors
- Barone, P. W., Parker, R. S., & Strano, M. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-11-02
- Volume
- 77
- Issue
- 23
- Pages
- 7556-7562
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2041033069
- Cited by
- 279
- References
- 37
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.