Capillary Isoelectric Focusing-Tandem Mass Spectrometry and Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry for Quantitative Proteomic Analysis of Differentiating PC12 Cells By Eight-Plex Isobaric Tags for Relative and Absolute Quantification
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We report the application of capillary isoelectric focusing for quantitative analysis of a complex proteome. Biological duplicates were generated from PC12 cells at days 0, 3, 7, and 12 following treatment with nerve growth factor. These biological duplicates were digested with trypsin, labeled using eight-plex isobaric tags for relative and absolute quantification (iTRAQ) chemistry, and pooled. The pooled peptides were separated into 25 fractions using reversed-phase liquid chromatography (RPLC). Technical duplicates of each fraction were separated by capillary isoelectric focusing (cIEF) using a set of amino acids as ampholytes. The cIEF column was interfaced to an Orbitrap Velos mass spectrometer with an electrokinetically pumped sheath-flow nanospray interface. This HPLC-cIEF-electrospray-tandem mass spectrometry (ESI-MS/MS) approach identified 835 protein groups and produced 2,329 unique peptides IDs. The biological duplicates were analyzed in parallel using conventional strong-cation exchange (SCX)-RPLC-ESI-MS/MS. The iTRAQ peptides were first separated into eight fractions using SCX. Each fraction was then analyzed by RPLC-ESI-MS/MS. The SCX-RPLC approach generated 1,369 protein groups and 3,494 unique peptide IDs. For protein quantitation, 96 and 198 differentially expressed proteins were obtained with RPLC-cIEF and SCX-RPLC, respectively. The combined set identified 231 proteins. Protein expression changes measured by RPLC-cEIF and SCX-RPLC were highly correlated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Syntaxin: A Synaptic Protein Implicated in Docking of Synaptic Vesicles at Presynaptic Active Zones
Bennett, M. K., Calakos, N., & Scheller, R. H. (1992) · Science · doi:10.1126/science.1321498 · Cited by 1,263
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Self-citationWang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128
Self-citationZhu, G., Sun, L., Yan, X., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac303750g · Cited by 103
Self-citationCE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
Wojcik, R., Li, Y., MacCoss, M. J., & Dovichi, N. J. (2012) · Talanta · doi:10.1016/j.talanta.2011.10.048 · Cited by 43
Self-citation
Cited by
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Self-citationCE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Simplified capillary isoelectric focusing with chemical mobilization for intact protein analysis
Zhu, G., Sun, L., & Dovichi, N. J. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601051 · Cited by 23
Self-citation
Metadata
- Authors
- Zhu, G., Sun, L., Keithley, R. B., & Dovichi, N. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-18
- Volume
- 85
- Issue
- 15
- Pages
- 7221-7229
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1985515254
- Cited by
- 30
- References
- 9
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary Isoelectric Focusing-Tandem Mass Spectrometry and Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry for Quantitative Proteomic Analysis of Differentiating PC12 Cells By Eight-Plex Isobaric Tags for Relative and Absolute Quantification. https://app.cochat.ai/papers/10.1021/ac4009868
- The paper
- Zhu, G., Sun, L., Keithley, R. B., & Dovichi, N. J. (2013). Capillary Isoelectric Focusing-Tandem Mass Spectrometry and Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry for Quantitative Proteomic Analysis of Differentiating PC12 Cells By Eight-Plex Isobaric Tags for Relative and Absolute Quantification. Analytical Chemistry. https://doi.org/10.1021/ac4009868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.