The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Ion Mobility Derived Collision Cross Sections to Support Metabolomics Applications
Open accessAbstract
Metabolomics is a rapidly evolving analytical approach in life and health sciences. The structural elucidation of the metabolites of interest remains a major analytical challenge in the metabolomics workflow. Here, we investigate the use of ion mobility as a tool to aid metabolite identification. Ion mobility allows for the measurement of the rotationally averaged collision cross-section (CCS), which gives information about the ionic shape of a molecule in the gas phase. We measured the CCSs of 125 common metabolites using traveling-wave ion mobility-mass spectrometry (TW-IM-MS). CCS measurements were highly reproducible on instruments located in three independent laboratories (RSD < 5% for 99%). We also determined the reproducibility of CCS measurements in various biological matrixes including urine, plasma, platelets, and red blood cells using ultra performance liquid chromatography (UPLC) coupled with TW-IM-MS. The mean RSD was < 2% for 97% of the CCS values, compared to 80% of retention times. Finally, as proof of concept, we used UPLC-TW-IM-MS to compare the cellular metabolome of epithelial and mesenchymal cells, an in vitro model used to study cancer development. Experimentally determined and computationally derived CCS values were used as orthogonal analytical parameters in combination with retention time and accurate mass information to confirm the identity of key metabolites potentially involved in cancer. Thus, our results indicate that adding CCS data to searchable databases and to routine metabolomics workflows will increase the identification confidence compared to traditional analytical approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sumner, L. W., Amberg, A., Barrett, D., Beale, M. H., Beger, R., Daykin, C. A., Fan, T. W.-M., Fiehn, O., Goodacre, R., Griffin, J. L., et al. (2007) · Metabolomics · doi:10.1007/s11306-007-0082-2 · Cited by 5,368
The Human Serum Metabolome (HUSERMET) Consortium, Dunn, W. B., Broadhurst, D., Begley, P., Zelena, E., Francis-McIntyre, S., Anderson, N., Brown, M., Knowles, J. D., Halsall, A., et al. (2011) · Nature Protocols · doi:10.1038/nprot.2011.335 · Cited by 3,294
Snail, Zeb and bHLH factors in tumour progression: An alliance against the epithelial phenotype?
Peinado, H., Olmeda, D., & Cano, A. (2007) · Nature reviews. Cancer · doi:10.1038/nrc2131 · Cited by 3,121
HMDB 3.0—The Human Metabolome Database in 2013
Wishart, D. S., Jewison, T., Guo, A. C., Wilson, M., Knox, C., Liu, Y., Djoumbou, Y., Mandal, R., Aziat, F., Dong, E., et al. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks1065 · Cited by 2,845
Metabolomics: the apogee of the omics trilogy
Patti, G. J., Yanes, O., & Siuzdak, G. (2012) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3314 · Cited by 2,571
Mass spectrometry‐based metabolomics
Dettmer, K., Aronov, P. A., & Hammock, B. D. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20108 · Cited by 2,241
METLIN—a metabolite mass spectral database
Smith, C. A., Maille, G. O., Want, E. J., Qin, C., Trauger, S. A., Brandon, T. R., Custodio, D. E., Abagyan, R., & Siuzdak, G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000179845.53213.39 · Cited by 2,226
PubChem: Integrated Platform of Small Molecules and Biological Activities
(2008) · Annual Reports in Computational Chemistry · doi:10.1016/s1574-1400(08)00012-1 · Cited by 1,263
Global metabolic profiling procedures for urine using UPLC–MS
Want, E. J., Wilson, I. D., Gika, H., Theodoridis, G., Plumb, R. S., Shockcor, J., Holmes, E., & Nicholson, J. K. (2010) · Nature Protocols · doi:10.1038/nprot.2010.50 · Cited by 1,169
Ion mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Structural Information from Ion Mobility Measurements: Effects of the Long-Range Potential
Mesleh, M. F., Hunter, J. M., Shvartsburg, A. A., Schatz, G. C., & Jarrold, M. F. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp961623v · Cited by 1,043
Dunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
An exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819
Aigner, K., Dampier, B., Descovich, L., Mikula, M., Sultan, A., Schreiber, M., Mikulits, W., Brabletz, T., Strand, D., Obrist, P., et al. (2007) · Oncogene · doi:10.1038/sj.onc.1210508 · Cited by 617
Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., Levin, Y., Schild, H., & Tenzer, S. (2014) · Nature Methods · doi:10.1038/nmeth.2767 · Cited by 481
Zhu, Z.-J., Schultz, A. W., Wang, J., Johnson, C. H., Yannone, S. M., Patti, G. J., & Siuzdak, G. (2013) · Nature Protocols · doi:10.1038/nprot.2013.004 · Cited by 477
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Campuzano, I., Bush, M. F., Robinson, C. V., Beaumont, C., Richardson, K., Kim, H., & Kim, H. I. (2012) · Analytical Chemistry · doi:10.1021/ac202625t · Cited by 383
Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies
Bush, M. F., Campuzano, I. D. G., & Robinson, C. V. (2012) · Analytical Chemistry · doi:10.1021/ac3014498 · Cited by 315
Ivanisevic, J., Zhu, Z.-J., Plate, L., Tautenhahn, R., Chen, S., O’Brien, P. J., Johnson, C. H., Marletta, M. A., Patti, G. J., & Siuzdak, G. (2013) · Analytical Chemistry · doi:10.1021/ac401140h · Cited by 264
Castro-Perez, J. M., Kamphorst, J., DeGroot, J., Lafeber, F., Goshawk, J., Yu, K., Shockcor, J. P., Vreeken, R. J., & Hankemeier, T. (2010) · Journal of Proteome Research · doi:10.1021/pr901094j · Cited by 236
Lipid analysis and lipidomics by structurally selective ion mobility-mass spectrometry
Kliman, M., May, J. C., & McLean, J. A. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.016 · Cited by 218
Fenn, L. S., Kliman, M., Mahsut, A., Zhao, S. R., & McLean, J. A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2666-3 · Cited by 198
Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS)
Dwivedi, P., Schultz, A. J., & Jr, H. H. H. (2010) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2010.02.007 · Cited by 168
HILIC-UPLC-MS for Exploratory Urinary Metabolic Profiling in Toxicological Studies
Spagou, K., Wilson, I. D., Masson, P., Theodoridis, G. A., Raikos, Ν., Coen, M., Holmes, E. C., Lindon, J. C., Plumb, R. S., Nicholson, J. K., et al. (2010) · Analytical Chemistry · doi:10.1021/ac102523q · Cited by 148
Castro‐Perez, J. M., Roddy, T. P., Nibbering, N. M. M., Shah, V., McLaren, D. G., Previs, S. F., Attygalle, A. B., Herath, K. B., Chen, Z., Wang, S., et al. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0172-2 · Cited by 112
Endothelial Induced EMT in Breast Epithelial Cells with Stem Cell Properties
Sigurðsson, V., Hilmarsdóttir, B., Sigmundsdóttir, H., Fridriksdottir, A. J., Ringnér, M., Villadsen, R., Borg, Å., Agnarsson, B. A., Petersen, O. W., Magnússon, M. K., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023833 · Cited by 108
MALDI-MS imaging of lipids in ex vivo human skin
Hart, P. J., Francese, S., Claude, E., Woodroofe, M. N., & Clench, M. R. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5090-4 · Cited by 91
Paglia, G., Ifa, D. R., Wu, C., Corso, G., & Cooks, R. G. (2010) · Analytical Chemistry · doi:10.1021/ac902325j · Cited by 86
Self-citationFu, W., Magnúsdóttir, M., Brynjólfsson, S., Palsson, B. Ø., & Paglia, G. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6434-4 · Cited by 82
Self-citationPaglia, G., Hrafnsdóttir, S., Magnúsdóttir, M., Fleming, R. M. T., Thorlacius, S., Palsson, B. Ø., & Thiele, I. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5556-4 · Cited by 81
Self-citationA practical guide to metabolomic profiling as a discovery tool for human heart disease
Heather, L. C., Wang, X., West, J. A., & Griffin, J. L. (2012) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2012.12.001 · Cited by 78
Chong, W. P. K., Goh, L. T., Reddy, S. G., Yusufi, F. N. K., Lee, D., Wong, N. S. C., Heng, C., Yap, M. G. S., & Ho, Y. S. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4328 · Cited by 78
Improving Qualitative and Quantitative Performance for MSE-based Label-free Proteomics
Bond, N. J., Shliaha, P. V., Lilley, K. S., & Gatto, L. (2013) · Journal of Proteome Research · doi:10.1021/pr300776t · Cited by 72
Fasciotti, M., Sanvido, G. B., Santos, V. G., Lalli, P. M., McCullagh, M., de Sá, G. F., Daroda, R. J., Peter, M. G., & Eberlin, M. N. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3089 · Cited by 69
Kaplan, K. A., Dwivedi, P., Davidson, S., Yang, Q., Tso, P., Siems, W. F., & Hill, H. H. (2009) · Analytical Chemistry · doi:10.1021/ac901030k · Cited by 68
MolFind: A Software Package Enabling HPLC/MS-Based Identification of Unknown Chemical Structures
Menikarachchi, L. C., Cawley, S., Hill, D. W., Hall, L. M., Hall, L. H., Lai, S., Wilder, J., & Grant, D. F. (2012) · Analytical Chemistry · doi:10.1021/ac302048x · Cited by 67
Self-citationGeromanos, S. J., Hughes, C. J., Ciavarini, S. J., Vissers, J. P. C., & Langridge, J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6197-y · Cited by 66
Self-citationShah, V., Castro‐Perez, J. M., McLaren, D. G., et al. (2013) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6675 · Cited by 57
Harry, E. L., Weston, D. J., Bristow, A. W. T., Wilson, I. D., & Creaser, C. S. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.04.043 · Cited by 53
Paglia, G., Magnúsdóttir, M., Thorlacius, S., Sigurjónsson, Ó. E., Guðmundsson, S., Palsson, B. Ø., & Thiele, I. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.04.026 · Cited by 53
Self-citationMalkar, A., Devenport, N. A., Martin, H. J., Patel, P., Turner, M. A., Watson, P., Maughan, R. J., Reid, H. J., Sharp, B. L., Thomas, C. L. P., et al. (2013) · Metabolomics · doi:10.1007/s11306-013-0541-x · Cited by 51
O'Brien, P. J., Lee, M. H., Spilker, M. E., et al. (2013) · Cancer & Metabolism · doi:10.1186/2049-3002-1-4 · Cited by 49
Cited by
Metabolomics: beyond biomarkers and towards mechanisms
Johnson, C. H., Ivanisevic, J., & Siuzdak, G. (2016) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2016.25 · Cited by 2,829
Untargeted Metabolomics Strategies—Challenges and Emerging Directions
Schrimpe-Rutledge, A. C., Codreanu, S. G., Sherrod, S. D., & McLean, J. A. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1469-y · Cited by 1,372
Cajka, T., & Fiehn, O. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04491 · Cited by 830
Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Current approaches and challenges for the metabolite profiling of complex natural extracts
Wolfender, J.-L., Marti, G., Thomas, A., & Bertrand, S. (2015) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.10.091 · Cited by 635
Metadata
- Authors
- Paglia, G., Williams, J. P., Menikarachchi, L., Thompson, J. W., Tyldesley-Worster, R., Halldórsson, S., Rolfsson, O., Moseley, A., Grant, D., Langridge, J., Palsson, B. O., & Astarita, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-03-28
- Volume
- 86
- Issue
- 8
- Pages
- 3985-3993
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965038686
- Cited by
- 319
- References
- 43
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.