The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Abstract
The majority of bioassays utilize thermosensitive reagents (e.g., biomolecules) and laboratory conditions for analysis. The developing world, however, requires inexpensive, simple-to-perform tests that do not require refrigeration or access to highly trained technicians. To address this need, paper-based bioassays using gold nanoparticle (AuNP) colorimetric probes have been developed. In the two prototype DNase I and adenosine-sensing assays, blue (or black)-colored DNA-cross-linked AuNP aggregates were spotted on paper substrates. The addition of target DNase I (or adenosine) solution dissociated the gold aggregates into dispersed AuNPs, which generated an intense red color on paper within one minute. Both hydrophobic and (poly(vinyl alcohol)-coated) hydrophilic paper substrates were suitable for this biosensing platform; by contrast, uncoated hydrophilic paper caused "bleeding" and premature cessation of the assay due to surface drying. The assays are surprisingly thermally stable. During preparation, AuNP aggregate-coated papers can be dried at elevated temperatures (e.g., 90 degrees C) without significant loss of biosensing performance, which suggests the paper substrate protects AuNP aggregate probes from external nonspecific stimuli (e.g., heat). Moreover, the dried AuNP aggregate-coated papers can be stored for at least several weeks without loss of the biosensing function. The combination of paper substrates and AuNP colorimetric probes makes the final products inexpensive, low-volume, portable, disposable, and easy-to-use. We believe this simple, practical bioassay platform will be of interest for use in areas such as disease diagnostics, pathogen detection, and quality monitoring of food and water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
A study of the nucleation and growth processes in the synthesis of colloidal gold
Turkevich, J., Stevenson, P. C., & Hillier, J. (1951) · Discussions of the Faraday Society · doi:10.1039/df9511100055 · Cited by 7,792
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Elghanian, R., Storhoff, J. J., Mucic, R. C., Letsinger, R. L., & Mirkin, C. A. (1997) · Science · doi:10.1126/science.277.5329.1078 · Cited by 4,399
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Ghosh, S. K., & Pal, T. (2007) · Chemical Reviews · doi:10.1021/cr0680282 · Cited by 2,782
Exploitation of Localized Surface Plasmon Resonance
Hutter, E., & Fendler, J. H. (2004) · Advanced Materials · doi:10.1002/adma.200400271 · Cited by 2,726
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Li, H., & Rothberg, L. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406115101 · Cited by 1,342
Liu, J., & Lu, Y. (2006) · Nature Protocols · doi:10.1038/nprot.2006.38 · Cited by 1,126
Cited by
Multiplexed and portable nucleic acid detection platform with Cas13, Cas12a, and Csm6
Gootenberg, J. S., Abudayyeh, O. O., Kellner, M. J., Joung, J., Collins, J. J., & Zhang, F. (2018) · Science · doi:10.1126/science.aaq0179 · Cited by 2,638
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Wood-Derived Materials for Green Electronics, Biological Devices, and Energy Applications
Zhu, H., Luo, W., Ciesielski, P. N., Fang, Z., Zhu, J. Y., Henriksson, G., Himmel, M. E., & Hu, L. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00225 · Cited by 1,532
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Recent Advances in Paper-Based Sensors
Liana, D. D., Raguse, B., Gooding, J. J., & Chow, E. (2012) · Sensors · doi:10.3390/s120911505 · Cited by 660
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Paper-based nanobiosensors for diagnostics
Parolo, C., & Merkoçi, A. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35255a · Cited by 550
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Colorimetric sensors for rapid detection of various analytes
Piriya V.S, A., Joseph, P., Daniel S.C.G., K., Lakshmanan, S., Kinoshita, T., & Muthusamy, S. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.018 · Cited by 441
Wang, Z., & Ma, L. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2009.01.005 · Cited by 383
Simple, distance-based measurement for paper analytical devices
Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50072a · Cited by 348
Vella, S. J., Beattie, P., Cademartiri, R., Laromaine, A., Martinez, A. W., Phillips, S. T., Mirica, K. A., & Whitesides, G. M. (2012) · Analytical Chemistry · doi:10.1021/ac203434x · Cited by 333
Yu, J., Ge, L., Huang, J., Wang, S., & Ge, S. (2011) · Lab on a Chip · doi:10.1039/c0lc00524j · Cited by 327
Hossain, S. M. Z., Luckham, R. E., McFadden, M. J., & Brennan, J. D. (2009) · Analytical Chemistry · doi:10.1021/ac901714h · Cited by 316
Inkjet Printed Surface Enhanced Raman Spectroscopy Array on Cellulose Paper
Yu, W. W., & White, I. M. (2010) · Analytical Chemistry · doi:10.1021/ac102475k · Cited by 304
β-Galactosidase-Based Colorimetric Paper Sensor for Determination of Heavy Metals
Hossain, S. M. Z., & Brennan, J. D. (2011) · Analytical Chemistry · doi:10.1021/ac202290d · Cited by 297
Plasmonic colorimetric and SERS sensors for environmental analysis
Wei, H., Hossein Abtahi, S. M., & Vikesland, P. J. (2015) · Environmental Science: Nano · doi:10.1039/c4en00211c · Cited by 285
Paper based diagnostics for personalized health care: Emerging technologies and commercial aspects
Mahato, K., Srivastava, A., & Chandra, P. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.05.001 · Cited by 280
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Dalirirad, S., & Steckl, A. J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.161 · Cited by 259
Metadata
- Authors
- Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-10-11
- Volume
- 80
- Issue
- 22
- Pages
- 8431-8437
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064715286
- Cited by
- 338
- References
- 27
- FWCI
- 16.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.