Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Ion/ion proton transfer reactions are shown to be an effective means to facilitate the resolution of ions in electrospray mass spectrometry that differ in mass and charge but are similar in mass-to-charge ratio. Examples are shown in which a minor contaminant protein in a ribonuclease B solution is clearly apparent after ion/ion proton transfer but not in the conventional electrospray mass spectrum. A further example involving a mixture of bovine serum albumin and bovine transferrin also showed the identification of previously unnoticed "contaminant" polymer. The latter mixture also illustrated important issues in the use of the quadrupole ion trap as a reaction vessel and mass analyzer for high mass-to-charge ratio ions. The results suggest that the use of ion trap operating parameters specifically tailored for storage, ejection, detection, and mass-to-charge analysis of high mass-to-charge ratio ions can have attractive analytical figures of merit for determining mixtures of relatively high-mass proteins and, by extension, other types of high-mass biopolymers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a multiply charged cation is let to react with a singly charged anion (typically originated from a perfluorinated molecule) to generate a cation with reduced charge state and a neutral molecule (that produces no signal during m/z analysis)”
From Proton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms (2019) · cites this paper as [28]
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
Correction of13C Mass Isotopomer Distributions for Natural Stable Isotope Abundance
Fernandez, C. A., Rosiers, C. D., Previs, S. F., David, F., & Brunengraber, H. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199603)31:3<255::aid-jms290>3.0.co;2-3 · Cited by 397
Some Developments in Nuclear Magnetic Resonance of Solids
Chmelka, B. F., & Pines, A. (1989) · Science · doi:10.1126/science.246.4926.71 · Cited by 379
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Enhancement of uphill transport by a double carrier membrane system
Sugawara, M., Omoto, M., Yoshida, H., & Umezawa, Y. (1988) · Analytical Chemistry · doi:10.1021/ac00171a029 · Cited by 320
Nordhoff, E., Ingendoh, A., Cramer, R., Overberg, A., Stahl, B., Karas, M., Hillenkamp, F., Crain, P. F., & Chait, B. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290061212 · Cited by 297
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00130a015 · Cited by 216
Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Self-citationTrapping, detection and reaction of very large single molecular ions by mass spectrometry
Smith, R. D., Cheng, X., Brace, J. E., Hofstadler, S. A., & Anderson, G. A. (1994) · Nature · doi:10.1038/369137a0 · Cited by 200
Reactions of dimethylamine with multiply charged ions of cytochrome c
McLuckey, S. A., Van Berkel, G. J., & Glish, G. L. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00170a057 · Cited by 185
Self-citationPham, E. K., & Chang, S.-G. (1994) · Nature · doi:10.1038/369139a0 · Cited by 140
Matrix‐assisted laser desorption of large biomolecules with a TEA‐CO 2 ‐laser
Overberg, A., Karas, M., Hillenkamp, F., & Cotter, R. J. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050308 · Cited by 137
Method for the electrospray ionization of highly conductive aqueous solutions
Chowdhury, S. K., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00015a030 · Cited by 137
Mahoney, J. F., Perel, J., Ruatta, S. A., Martino, P. A., Husain, S., Cook, K., & Lee, T. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290051004 · Cited by 136
Cassady, C. J., & Carr, S. R. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199603)31:3<247::aid-jms285>3.0.co;2-l · Cited by 119
Electrospray ionization mass spectrometry: Deconvolution by an Entropy-Based algorithm
Reinhold, B. B., & Reinhold, V. N. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87004-i · Cited by 113
Chowdhury, S. K., Katta, V., Beavis, R. C., & Chait, B. T. (1990) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(90)85018-h · Cited by 111
Surface-induced dissociation by Fourier transform mass spectrometry
Ijames, C. F., & Wilkins, C. L. (1990) · Analytical Chemistry · doi:10.1021/ac00212a017 · Cited by 107
Feng, R., Konishi, Y., & Bell, A. W. (1991) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(91)85005-q · Cited by 105
Shock wave model for sputtering biomolecules using massive cluster impacts
Mahoney, J. F., Perel, J., Lee, T. D., Martino, P. A., & Williams, P. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)87058-7 · Cited by 95
Winger, B. E., Light-Wahl, K. J., & Smith, R. D. (1992) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(92)85003-3 · Cited by 85
Kenndler, E., & Schwer, C. (1991) · Analytical Chemistry · doi:10.1021/ac00021a019 · Cited by 85
Deprotonation reactions of multiply protonated ubiquitin ions
Cassady, C. J., Wronka, J., Kruppa, G. H., Laukien, F. H., & Hettich, R. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080511 · Cited by 80
Hartwig, J. F., Andersen, R. A., & Bergman, R. G. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00170a058 · Cited by 72
Measurement of Coulomb Energy and Dielectric Polarizability of Gas-Phase Diprotonated Diaminoalkanes
Gross, D. S., Rodriguez‐Cruz, S. E., Bock, S., & Williams, E. R. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100012a025 · Cited by 68
Product Ion Charge State Determination via Ion/Ion Proton Transfer Reactions
Herron, W. J., Goeringer, D. E., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac950895b · Cited by 67
Self-citationHerron, W. J., Goeringer, D. E., & McLuckey, S. A. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00199-n · Cited by 67
Self-citationFast atom bombardment mass spectrometry of low temperature chloroaluminate and chlorogallate melts
Wicelinski, S. P., Gale, R. J., Pamidimukkala, K. M., & Laine, R. A. (1988) · Analytical Chemistry · doi:10.1021/ac00171a013 · Cited by 53
Three‐dimensional deconvolution of multiply charged spectra
Labowsky, M. J., Whitehouse, C., & Fenn, J. B. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070117 · Cited by 50
Ikonomou, M. G., & Kebarle, P. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)80099-m · Cited by 44
Brown, S. M., Busch, K. L., & Cotter, R. J. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021112 · Cited by 27
Kassel, D. B., Williams, K. P., Musselman, B. D., & Smith, J. A. (1991) · Analytical Chemistry · doi:10.1021/ac00018a015 · Cited by 20
Downstream Processing and Bioseparation
(1990) · Analytical Chemistry · doi:10.1021/ac00212a734 · Cited by 19
Primary Sequence and Glycation at Lysine-548 of Bovine Serum Albumin
Wada, Y. (1996) · Journal of Mass Spectrometry · Cited by 19
Combination electrospray-liquid secondary ion mass spectrometry ion source
Papac, D. I., Schey, K. L., & Knapp, D. R. (1991) · Analytical Chemistry · doi:10.1021/ac00015a029 · Cited by 16
Tolun, E., Proctor, C. J., Todd, J. F. J., Walshe, J. M. A., & Connor, J. A. (1984) · Organic Mass Spectrometry · doi:10.1002/oms.1210190608 · Cited by 15
Research works printed but not linked: 16
- Fenn J. B., 1990, Mass Spectrom. Rev., 9, 70
- Smith R. D., 1990, Anal. Chem., 62, 899
- Beu S. C., 1993, J. Am. Soc. Mass Spectrom., 4, 192
- Winger B. E., 1993, J. Am. Soc. Mass Spectrom., 4, 577
- Hunter A. P., 1994, Rapid Commun. Mass Spectrom., 8, 422
- Ogorzalek-Loo R. R., 1992, Rapid Commun. Mass Spectrom., 6, 165
- Ogorzalek Loo R. R., 1994, J. Am. Soc. Mass Spectrom., 5, 220
- McLuckey, S. A.; Van Berkel, G. J.; Glish, G. L.; Schwartz, J. C. InModern MassSpectrometry: Practical Aspects of Ion Trap Mass Spectrometry, Vol. 2; March, R. E., Todd, J. F. J., Eds., CRC Press: Boca Raton, FL, 1995; Chapter 3, pp 89−141.
- Gross D. S., 1995, J. Am. Chem. Soc., 117, 890
- Stephenson J. L., Int. J. Mass Spectrom. Ion Processes, in press.
- Kaiser R. E., 1989, Rapid Commun. Mass Spectrom., 3, 53
- Loo J. A., 1990, Biomed. Environ. Mass Spectrom., 19, 294
- Gillece-Castro, B.; Bourell, J. H.; Stults, J. T.Proceedings of the 39th ASMSConference on Mass Spectrometry and Allied Topics; Nashville, TN, May 19−24, 1991; p 276.
- Lisek, C.; Kolodziej, E.; Leimgruber, N.; Toren, P.; Hecht, R.; Howard, S.; Welply, J.; Allen, M.Proceedings of the 39th ASMS Conference on Mass Spectrometry and Allied Topics; Nashville, TN, May 19−24, 1991; p 278.
- Kent P. W., 1994, Pestic. Sci., 41, 228
- Wada Y., 1996, J. Mass Spectrom., 31, 266, 10.1002/(sici)1096-9888(199603)31:3<263::aid-jms292>3.0.co;2-2 · doi:10.1002/(sici)1096-9888(199603)31:3<263::aid-jms292>3.0.co;2-2
Cited by
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Self-citationIon/ion chemistry of high-mass multiply charged ions
McLuckey, S. A., & Stephenson, J. L. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:6<369::aid-mas1>3.0.co;2-j · Cited by 233
Self-citationWiesner, J., Premsler, T., & Sickmann, A. (2008) · PROTEOMICS · doi:10.1002/pmic.200800329 · Cited by 219
Metadata
- Authors
- Stephenson, J. L., & McLuckey, S. A.
- Affiliations
- Oak Ridge National Laboratory (US)
- ORCID
- McLuckey, Scott A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 22
- Pages
- 4026-4032
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2013608848
- Cited by
- 145
- References
- 41
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 4 · 2020: 6 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 5
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM045372)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- electrospray ionization mass spectrometry, protein mixtures, Paul trap, ribonuclease B, bovine serum albumin
- MeSH terms
- Animals, Cattle, Enzymes, Horses, Ions, Proteins, Protons, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.