CoChat

Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis

Stephenson, James L., McLuckey, Scott A. · 1996 · Analytical Chemistry

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

Ion/ion proton transfer reactions are shown to be an effective means to facilitate the resolution of ions in electrospray mass spectrometry that differ in mass and charge but are similar in mass-to-charge ratio. Examples are shown in which a minor contaminant protein in a ribonuclease B solution is clearly apparent after ion/ion proton transfer but not in the conventional electrospray mass spectrum. A further example involving a mixture of bovine serum albumin and bovine transferrin also showed the identification of previously unnoticed "contaminant" polymer. The latter mixture also illustrated important issues in the use of the quadrupole ion trap as a reaction vessel and mass analyzer for high mass-to-charge ratio ions. The results suggest that the use of ion trap operating parameters specifically tailored for storage, ejection, detection, and mass-to-charge analysis of high mass-to-charge ratio ions can have attractive analytical figures of merit for determining mixtures of relatively high-mass proteins and, by extension, other types of high-mass biopolymers.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac9605657

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 16

  1. Fenn J. B., 1990, Mass Spectrom. Rev., 9, 70
  2. Smith R. D., 1990, Anal. Chem., 62, 899
  3. Beu S. C., 1993, J. Am. Soc. Mass Spectrom., 4, 192
  4. Winger B. E., 1993, J. Am. Soc. Mass Spectrom., 4, 577
  5. Hunter A. P., 1994, Rapid Commun. Mass Spectrom., 8, 422
  6. Ogorzalek-Loo R. R., 1992, Rapid Commun. Mass Spectrom., 6, 165
  7. Ogorzalek Loo R. R., 1994, J. Am. Soc. Mass Spectrom., 5, 220
  8. McLuckey, S. A.; Van Berkel, G. J.; Glish, G. L.; Schwartz, J. C. InModern MassSpectrometry: Practical Aspects of Ion Trap Mass Spectrometry, Vol. 2; March, R. E., Todd, J. F. J., Eds., CRC Press: Boca Raton, FL, 1995; Chapter 3, pp 89−141.
  9. Gross D. S., 1995, J. Am. Chem. Soc., 117, 890
  10. Stephenson J. L., Int. J. Mass Spectrom. Ion Processes, in press.
  11. Kaiser R. E., 1989, Rapid Commun. Mass Spectrom., 3, 53
  12. Loo J. A., 1990, Biomed. Environ. Mass Spectrom., 19, 294
  13. Gillece-Castro, B.; Bourell, J. H.; Stults, J. T.Proceedings of the 39th ASMSConference on Mass Spectrometry and Allied Topics; Nashville, TN, May 19−24, 1991; p 276.
  14. Lisek, C.; Kolodziej, E.; Leimgruber, N.; Toren, P.; Hecht, R.; Howard, S.; Welply, J.; Allen, M.Proceedings of the 39th ASMS Conference on Mass Spectrometry and Allied Topics; Nashville, TN, May 19−24, 1991; p 278.
  15. Kent P. W., 1994, Pestic. Sci., 41, 228
  16. Wada Y., 1996, J. Mass Spectrom., 31, 266, 10.1002/(sici)1096-9888(199603)31:3<263::aid-jms292>3.0.co;2-2 · doi:10.1002/(sici)1096-9888(199603)31:3<263::aid-jms292>3.0.co;2-2

Cited by

See all 147

Metadata

Authors
Stephenson, J. L., & McLuckey, S. A.
Affiliations
Oak Ridge National Laboratory (US)
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
22
Pages
4026-4032
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2013608848
Cited by
145
References
41
Citations by year
2026: 5 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 4 · 2020: 6 · 2019: 3 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 5
FWCI
4.61
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (R01GM045372)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
electrospray ionization mass spectrometry, protein mixtures, Paul trap, ribonuclease B, bovine serum albumin
MeSH terms
Animals, Cattle, Enzymes, Horses, Ions, Proteins, Protons, Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.