Accuracy of the One-Point in Vivo Calibration of “Wired” Glucose Oxidase Electrodes Implanted in Jugular Veins of Rats in Periods of Rapid Rise and Decline of the Glucose Concentration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The hypothesis of the feasibility of one-point in vivo calibration of intravenously implanted glucose sensors during periods of rapid rise and decline of venous blood glucose concentration was tested. Miniature (5 x 10(-4) cm2 mass transporting area) glucose electrodes with 10-90% response times < 2 min, that did not consume oxygen, were implanted in jugular veins of systemically heparinized rats and used in 4-h experiments, during which the blood glucose concentration was amperometrically monitored. The glucose electrodes were made by electrically connecting ("wiring") reaction centers of glucose oxidase through an electron-conducting redox hydrogel to gold electrode surfaces. The redox polymer and enzyme constituting the electrode sensing layer were immobilized by cross-linking, and thus the electrodes had no diffusional and readily leached redox mediator. One hour after their implantation, the electrodes accurately tracked the blood glucose concentration when calibrated in vivo by a one-point calibration, when the glucose concentration was steady, when rising rapidly, and when declining steeply. For an assumed 2-min lag time, the sensor readings were well correlated with the true blood glucose concentrations, with linear regression analysis yielding a slope of 0.97 +/- 0.07 and an intercept (bias) of 0.3 +/- 0.3 mM. The correlation coefficient, r2, was 0.949 +/- 0.020, and the percent difference through the 2-22 mM range was 1.9 +/- 1.0%. The results suggest that, in combination with understanding and modeling of transient physiological differences between the subcutaneous and the blood glucose concentrations, it will be possible to calibrate by one-point in vivo calibration subcutaneously implanted sensors, even while the glucose concentration changes rapidly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Self-citation
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Metallopolymers: New Multifunctional Materials
Whittell, G. R., & Manners, I. (2007) · Advanced Materials · doi:10.1002/adma.200702876 · Cited by 532
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citationPang, X., He, D., Luo, S., & Cai, Q. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2008.09.051 · Cited by 221
Implanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citationKoschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181
An improved sensitivity nonenzymatic glucose biosensor based on a Cu O modified electrode
Li, C., Su, Y., Zhang, S., Lv, X., Xia, H., & Wang, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.007 · Cited by 179
Yu, J., Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00199-4 · Cited by 171
“Although glucose sensors have been well-studied (Tatsu et al., 1992; Narang et al., 1994; Schmidtke and Heller, 1998; Vidal et al., 1998; Yao and Takashima, 1998), few works have fully quantified their analytical performance such as the stability, affinity and characterization of immobilized…”
Background
Metadata
- Authors
- Schmidtke, D. W., & Heller, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-04-01
- Volume
- 70
- Issue
- 10
- Pages
- 2149-2155
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1974210454
- Cited by
- 65
- References
- 1
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.