Quantitative Chemical Measurements of Vesicular Transmitters with Electrochemical Cytometry
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Electrochemical cytometry adds a new dimension to our ability to study the chemistry and chemical storage of transmitter molecules stored in nanometer vesicles. The approach involves the adsorption and subsequent rupture of vesicles on an electrode surface during which the electroactive contents are quantitatively oxidized (or reduced). The measured current allows us to count the number of molecules in the vesicles using Faraday's law and to correlate this to the amount of molecules released when single exocytosis events take place at communicating cells. The original format for this method involved a capillary electrophoresis separation step to singly address each vesicle, but we have more recently discovered that cellular vesicles tend to adsorb to carbon electrodes and spontaneously as well as stochastically rupture to give mostly single vesicle events. This approach, called impact electrochemical cytometry, even though the impact is perhaps not the important part of this process, has been studied and the vesicle rupture appears to be at the interface between the vesicle and the electrode and is probably driven by electroporation. The pore size and rate of content electrolysis are a function of the pore diameter and the presence of a protein core in the vesicles. In model liposomes with no protein, events appear extremely rapidly as the soft nanoparticles impact the electrode and the contents are oxidized. It appears that the proteins decorating the surface of the vesicle are important in maintaining a gap from the electrode and when this gap is closed electroporation takes place. Models of the event response times suggest the pores formed are small enough so we can carry out these measurements at nanotip electrodes and we have used this to quantify the vesicle content in living cells in a mode we call intracellular impact electrochemical cytometry. The development of electrochemical cytometry allows comparison between vesicle content and vesicular release and we have found that only part of the vesicle content is released in typical exocytotic cases measured by amperometry. This has led to the novel hypothesis that most exocytosis from dense core vesicles is via mechanism where vesicles fuse with the cell membrane, some content is released and then close again to be reloaded and reused. It leaves open the possibility that cells regulate release during individual events. This might be important in learning and memory and be a nonreceptor pharmaceutical target for brain-related disorders. Indeed, the concept of the chemo-brain observed in cisplatin-treated cancer patients appears to be at least in part the result of changing the fraction of transmitter released and we have been able to show this by using the combined amperometric measurement of release and electrochemical cytometry at model cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wightman, R. M., Jankowski, J. A., Kennedy, R. T., Kawagoe, K. T., Schroeder, T. J., Leszczyszyn, D. J., Near, J. A., Diliberto, E. J., & Viveros, O. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.23.10754 · Cited by 893
Chow, R. H., von Rüden, L., & Neher, E. (1992) · Nature · doi:10.1038/356060a0 · Cited by 817
Sulzer, D., & Rayport, S. (1990) · Neuron · doi:10.1016/0896-6273(90)90339-h · Cited by 389
Dunevall, J., Fathali, H., Najafinobar, N., Lovric, J., Wigström, J., Cans, A.-S., & Ewing, A. G. (2015) · Journal of the American Chemical Society · doi:10.1021/ja512972f · Cited by 196
Self-citationElectrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode
Lebègue, E., Anderson, C. M., Dick, J. E., Webb, L. J., & Bard, A. J. (2015) · Langmuir · doi:10.1021/acs.langmuir.5b03123 · Cited by 137
Cited by
Fundamentals of fast-scan cyclic voltammetry for dopamine detection
Venton, B. J., & Cao, Q. (2020) · The Analyst · doi:10.1039/c9an01586h · Cited by 357
Using single-vesicle technologies to unravel the heterogeneity of extracellular vesicles
Bordanaba-Florit, G., Royo, F., Kruglik, S. G., & Falcón-Pérez, J. M. (2021) · Nature Protocols · doi:10.1038/s41596-021-00551-z · Cited by 325
Perspective and Prospectus on Single-Entity Electrochemistry
Baker, L. A. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09747 · Cited by 285
Measuring synaptic vesicles using cellular electrochemistry and nanoscale molecular imaging
Phan, N. T. N., Li, X., & Ewing, A. G. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0048 · Cited by 250
Self-citationShin, W., Ge, L., Arpino, G., Villarreal, S. A., Hamid, E., Liu, H., Zhao, W.-D., Wen, P. J., Chiang, H.-C., & Wu, L.-G. (2018) · Cell · doi:10.1016/j.cell.2018.02.062 · Cited by 210
“Second, postsynaptic or amperometric current time course, which reflects transmitter release, diffusion, and postsynaptic or amperometric current generation, may imply fusion pore dynamics (Chow et al., 1992; Albillos et al., 1997;Wang et al., 2003;Alabi and Tsien, 2013; Li et al., 2016).”
Zwitterionic Polydopamine Engineered Interface for In Vivo Sensing with High Biocompatibility
Feng, T., Ji, W., Zhang, Y., Wu, F., Tang, Q., Wei, H., Mao, L., & Zhang, M. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202010675 · Cited by 194
Comi, T. J., Do, T. D., Rubakhin, S. S., & Sweedler, J. V. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12822 · Cited by 171
Lebègue, E., Barrière, F., & Bard, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02809 · Cited by 33
Detection of Bacterial Rhamnolipid Toxin by Redox Liposome Single Impact Electrochemistry
Luy, J., Ameline, D., Thobie‐Gautier, C., Boujtita, M., & Lebègue, E. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202111416 · Cited by 27
Recent advances in single liposome electrochemistry
Smida, H., Thobie-Gautier, C., Boujtita, M., & Lebègue, E. (2022) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2022.101141 · Cited by 11
Metadata
- Authors
- Li, X., Dunevall, J., & Ewing, A. G.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-09-13
- Volume
- 49
- Issue
- 10
- Pages
- 2347-2354
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2519567001
- Cited by
- 157
- References
- 5
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.