CoChat

Determination of Environmental Micro(Nano)Plastics by Matrix-Assisted Laser Desorption/Ionization–Time-of-Flight Mass Spectrometry

Wu, Pengfei, Tang, Yuanyuan, Cao, Guodong, Li, Jiangpeng, Wang, Siqing, Chang, Xinyi, Dang, Miao, Jin, Hangbiao, Zheng, Chunmiao, Cai, Zongwei · 2020 · Analytical Chemistry
Cited by 122

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Abstract Micro­(nano)­plastics (MNPs) are widely acknowledged as global environmental threat while determination methods for MNPs are still lacking and becoming a growing concern. This study provides a novel method for MNPs identification/quantification by matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI–TOF MS). Factors affecting the measurement were optimized, including laser energy, matrix (M), analyte (A), cationization agent (C), and MAC volume ratio. Under the optimal conditions, the peaks representative of polystyrene (PS) and polyethylene terephthalate (PET) were identified, and the mass differences were consistent with the molecular weight of the corresponding oligomer. A quantitative correlation was built between normalized signal intensity and ln­[polymer concentration] with a correlation coefficient above 0.96 for low-molecular-weight polymers and 0.98 for high-molecular-weight polymers. Furthermore, two types of environmental MNP samples were prepared, including aviation cup particles as fresh plastics and aged MNPs extracted from river sediment. By using MALDI–TOF MS, the PS-related MNPs (in both aviation cup and sediment) consisted of C8H8 and C16H16O oligomers, while the PET-related MNPs (only found in sediment) were identified with repeated units of C10H8O4 and C12H12O4. According to the quantitative correlation curve, the contents of PS and PET MNPs were quantified as 8.56 ± 0.04 and 28.71 ± 0.20 mg·kg–1, respectively, in the collected sediment. This study is the first attempt to propose a quantification method with the employment of MALDI–TOF MS for aged MNPs analysis in environmental samples, which can not only supply an effective method for MNP analysis but also inspire future studies on the in situ distribution and transformation of MNPs in environmental and biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.0c01928

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Wu, P., Tang, Y., Cao, G., Li, J., Wang, S., Chang, X., Dang, M., Jin, H., Zheng, C., & Cai, Z.
Venue
Analytical Chemistry
Published
2020-09-03
Volume
92
Issue
21
Pages
14346-14356
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3083054000
Cited by
122
References
9
FWCI
2.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.