The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Metal–Organic Framework-Functionalized Paper-Based Electrochemical Biosensor for Ultrasensitive Exosome Assay
Abstract
The exosome has emerged as a promising noninvasive biomarker for the early diagnosis of cancer. Therefore, it is highly desirable to develop simple, inexpensive, and user-friendly biosensors for convenient, sensitive, and quantitative exosome assay. Herein, we developed a simple and cost-efficient electrochemical biosensor by combining a metal–organic framework (MOF)-functionalized paper and a screen-printed electrode (SPE) for portable, ultrasensitive, and quantitative determination of cancer-derived exosomes. In principle, the biosensor relied on recognition of the exosome by Zr-MOFs and aptamer to initiate the hybridization chain reaction (HCR) and the formation of DNAzyme for signal amplification. Benefiting from the high signal amplification ability of HCR, the label-free paper-based biosensor is capable of ultrasensitive exosome assay with a detection limit down to 5 × 10 3 particles/mL, which is superior to that of most reported methods. Moreover, the proposed paper-based biosensor possessed the advantages of low cost, simple operation, and high sensitivity, making it affordable and deliverable for point-of-care (POC) diagnosis in resource-limited settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology , function , and biomedical applications of exosomes
Kalluri, R., & LeBleu, V. S. (2020) · Science · doi:10.1126/science.aau6977 · Cited by 10,770
Communication by Extracellular Vesicles: Where We Are and Where We Need to Go
Tkach, M., & Théry, C. (2016) · Cell · doi:10.1016/j.cell.2016.01.043 · Cited by 3,444
Extracellular vesicles in cancer — implications for future improvements in cancer care
Xu, R., Rai, A., Chen, M., Suwakulsiri, W., Greening, D. W., & Simpson, R. J. (2018) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-018-0036-9 · Cited by 1,445
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,321
Tumor-Derived Exosomes and Their Role in Cancer Progression
(2016) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2015.12.005 · Cited by 755
Johnsen, K. B., Gudbergsson, J. M., Skov, M. N., Pilgaard, L., Moos, T., & Duroux, M. (2014) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2014.04.005 · Cited by 704
Aptamer/AuNP Biosensor for Colorimetric Profiling of Exosomal Proteins
Jiang, Y., Shi, M., Liu, Y., Wan, S., Cui, C., Zhang, L., & Tan, W. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201703807 · Cited by 487
Wang, S., Zhang, L., Wan, S., Cansiz, S., Cui, C., Liu, Y., Cai, R., Hong, C., Teng, I.-T., Shi, M., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00373 · Cited by 476
Chang, J., Wang, X., Wang, J., Li, H., & Li, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05599 · Cited by 469
Self-citationYang, X., Tang, Q., Jiang, Y., Zhang, M., Wang, M., & Mao, L. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11996 · Cited by 403
Zhang, P., He, M., & Zeng, Y. (2016) · Lab on a Chip · doi:10.1039/c6lc00279j · Cited by 385
Wang, S., McGuirk, C. M., Ross, M. B., Wang, S., Chen, P., Xing, H., Liu, Y., & Mirkin, C. A. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b05633 · Cited by 295
Boriachek, K., Masud, M. K., Palma, C., Phan, H.-P., Yamauchi, Y., Hossain, M. S. A., Nguyen, N.-T., Salomon, C., & Shiddiky, M. J. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03619 · Cited by 291
λ-DNA- and Aptamer-Mediated Sorting and Analysis of Extracellular Vesicles
Liu, C., Zhao, J., Tian, F., Chang, J., Zhang, W., & Sun, J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b00007 · Cited by 264
Yang, L., Yin, X., An, B., & Li, F. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04308 · Cited by 263
Self-citationZhu, L., Wang, K., Cui, J., Liu, H., Bu, X., Ma, H., Wang, W., Gong, H., Lausted, C., Hood, L., et al. (2014) · Analytical Chemistry · doi:10.1021/ac5023056 · Cited by 258
Wang, Z., Fu, Y., Kang, Z., Liu, X., Chen, N., Wang, Q., Tu, Y., Wang, L., Song, S., Ling, D., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b07895 · Cited by 253
Self-citationLyu, Y., Cui, D., Huang, J., Fan, W., Miao, Y., & Pu, K. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201900092 · Cited by 234
Tracing Tumor‐Derived Exosomal PD‐L1 by Dual‐Aptamer Activated Proximity‐Induced Droplet Digital PCR
Lin, B., Tian, T., Lu, Y., Liu, D., Huang, M., Zhu, L., Zhu, Z., Song, Y., & Yang, C. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202015628 · Cited by 222
Molecular Recognition-Based DNA Nanoassemblies on the Surfaces of Nanosized Exosomes
Wan, S., Zhang, L., Wang, S., Liu, Y., Wu, C., Cui, C., Sun, H., Shi, M., Jiang, Y., Li, L., et al. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b00319 · Cited by 208
Recent Advances in Biosensors for Detecting Cancer-Derived Exosomes
Cheng, N., Du, D., Wang, X., Liu, D., Xu, W., Luo, Y., & Lin, Y. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.04.008 · Cited by 207
Bruch, R., Johnston, M., Kling, A., Mattmüller, T., Baaske, J., Partel, S., Madlener, S., Weber, W., Urban, G. A., & Dincer, C. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112887 · Cited by 202
ExoAPP: Exosome-Oriented, Aptamer Nanoprobe-Enabled Surface Proteins Profiling and Detection
Jin, D., Yang, F., Zhang, Y., Liu, L., Zhou, Y., Wang, F., & Zhang, G.-J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03959 · Cited by 199
Identification of Individual Exosome-Like Vesicles by Surface Enhanced Raman Spectroscopy
Stremersch, S., Marro, M., Pinchasik, B.-E., Baatsen, P., Hendrix, A., De Smedt, S. C., Loza-Alvarez, P., Skirtach, A. G., Raemdonck, K., & Braeckmans, K. (2016) · Small · doi:10.1002/smll.201600393 · Cited by 190
Sun, Z., Wang, L., Wu, S., Pan, Y., Dong, Y., Zhu, S., Yang, J., Yin, Y., & Li, G. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05241 · Cited by 180
Quantification of Exosome Based on a Copper-Mediated Signal Amplification Strategy
He, F., Wang, J., Yin, B.-C., & Ye, B.-C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01187 · Cited by 170
Gao, X., Li, X., Sun, X., Zhang, J., Zhao, Y., Liu, X., & Li, F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00018 · Cited by 163
Self-citationLiu, Y., Hou, W., Xia, L., Cui, C., Wan, S., Jiang, Y. Y., Yang, Y. P., Wu, Q., Qiu, L., & Tan, W. (2018) · Chemical Science · doi:10.1039/c8sc02210k · Cited by 149
Liu, X., Zhao, Y., & Li, F. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112832 · Cited by 144
Self-citationShao, B., & Xiao, Z. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.02.041 · Cited by 126
Picciolini, S., Gualerzi, A., Vanna, R., Sguassero, A., Gramatica, F., Bedoni, M., Masserini, M., & Morasso, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00941 · Cited by 122
A Universal Paper-Based Electrochemical Sensor for Zero-Background Assay of Diverse Biomarkers
Liu, X., Li, X., Gao, X., Ge, L., Sun, X., & Li, F. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b03860 · Cited by 122
Self-citationXu, L., Chopdat, R., Li, D., & Al‐Jamal, K. T. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112576 · Cited by 116
Oliveira-Rodríguez, M., Serrano‐Pertierra, E., Garcı́a, A. C., López‐Martín, S., Yáñez‐Mó, M., Cernuda‐Morollón, E., & Blanco‐López, M. C. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.001 · Cited by 107
Zhang, Y., Jiao, J., Wei, Y., Wang, D., Yang, C., & Xu, Z. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04136 · Cited by 98
Kashefi-Kheyrabadi, L., Kim, J., Chakravarty, S., Park, S., Gwak, H., Kim, S.-I., Mohammadniaei, M., Lee, M., Hyun, K.-A., & Jung, H. (2020) · Biosensors & bioelectronics · doi:10.1016/j.bios.2020.112622 · Cited by 92
Lee, J. H., Kim, H., Heo, Y., Yoo, Y. K., Han, S. I., Kim, C., Hur, D., Kim, H., Kang, J. Y., & Lee, J. H. (2019) · The Analyst · doi:10.1039/c9an01140d · Cited by 91
Advances in Exosome Analysis Methods with an Emphasis on Electrochemistry
Hashkavayi, A. B., Cha, B. S., Lee, E. S., Kim, S., & Park, K. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02745 · Cited by 91
Liu, W., Li, J., Wu, Y., Xing, S., Lai, Y., & Zhang, G. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.033 · Cited by 85
Wang, L., Yang, Y., Liu, Y., Ning, L., Xiang, Y., & Li, G. (2019) · Chemical Communications · doi:10.1039/c9cc00220k · Cited by 80
Yu, Y., Zhang, W. S., Guo, Y., Peng, H., Zhu, M., Miao, D., & Su, G. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112482 · Cited by 78
Li, X., Gao, X., Gai, P., Liu, X., & Li, F. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128701 · Cited by 78
Self-citationSun, Z., Wu, S., Ma, J., Shi, H., Wang, L., Sheng, A., Yin, T., Sun, L., & Li, G. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b10729 · Cited by 74
Yin, X., Hou, T., Huang, B., Yang, L., & Li, F. (2019) · Chemical Communications · doi:10.1039/c9cc07253e · Cited by 70
Self-citationTian, Q., He, C., Liu, G., Zhao, Y., Hui, L., Mu, Y., Tang, R., Luo, Y., Zheng, S., & Wang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00189 · Cited by 66
Self-citationA multipedal DNA walker for amplified detection of tumor exosomes
Miao, P., & Tang, Y. (2020) · Chemical Communications · doi:10.1039/d0cc01817a · Cited by 57
Pan, Y., Wang, L., Deng, Y., Wang, M., Peng, Y., Yang, J. A., & Li, G. (2020) · Chemical Communications · doi:10.1039/d0cc06113a · Cited by 47
Guo, Y., Cao, Q., & Feng, Q. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.036 · Cited by 42
A pH-responsive bioassay for paper-based diagnosis of exosomes via mussel-inspired surface chemistry
Yang, Y., Li, C., Shi, H., Chen, T., Wang, Z., & Li, G. (2018) · Talanta · doi:10.1016/j.talanta.2018.09.067 · Cited by 36
Proteomic content of circulating exosomes in dairy cows with or without uterine infection
Almughlliq, F. B., Koh, Y. Q., Peiris, H. N., Vaswani, K., McDougall, S., Graham, E. M., Burke, C. R., Arachchige, B. J., Reed, S., & Mitchell, M. D. (2018) · Theriogenology · doi:10.1016/j.theriogenology.2018.03.024 · Cited by 29
Metadata
- Authors
- Liu, X., Gao, X., Yang, L., Zhao, Y., & Li, F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-08-19
- Volume
- 93
- Issue
- 34
- Pages
- 11792-11799
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3193569631
- Cited by
- 334
- References
- 50
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.