Microfluidic Platform for Studying Chemotaxis of Adhesive Cells Revealed a Gradient-Dependent Migration and Acceleration of Cancer Stem Cells
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Recent studies reveal that solid tumors consist of heterogeneous cells with distinct phenotypes and functions. However, it is unclear how different subtypes of cancer cells migrate under chemotaxis. Here, we developed a microfluidic device capable of generating multiple stable gradients, culturing cells on-chip, and monitoring single cell migratory behavior. The microfluidic platform was used to study gradient-induced chemotaxis of lung cancer stem cell (LCSC) and differentiated LCSC (dLCSC) in real time. Our results showed the dynamic and differential response of both LCSC and dLCSC to chemotaxis, which was regulated by the β-catenin dependent Wnt signaling pathway. The microfluidic analysis showed that LCSC and dLCSC from the same origin behaved differently in the same external stimuli, suggesting the importance of cancer cell heterogeneity. We also observed for the first time the acceleration of both LCSC and dLCSC during chemotaxis caused by increasing local concentration in different gradients, which could only be realized through the microfluidic approach. The capability to analyze single cell chemotaxis under spatially controlled conditions provides a novel analytical platform for the study of cellular microenvironments and cancer cell metastasis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This dynamic response was regulated by the β-catenin dependent Wnt signaling pathway [202].”
From Microfluidic modelling of the tumor microenvironment for anti-cancer drug development (2019) · cites this paper as [202]
Citations
Cites
Cell Migration: Integrating Signals from Front to Back
Ridley, A. J., Schwartz, M. A., Burridge, K., Firtel, R. A., Ginsberg, M. H., Borisy, G., Parsons, J. T., & Horwitz, A. R. (2003) · Science · doi:10.1126/science.1092053 · Cited by 4,978
Microenvironmental regulation of metastasis
Joyce, J. A., & Pollard, J. W. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2618 · Cited by 3,684
Clarke, M. F., Dick, J. E., Dirks, P. B., Eaves, C. J., Jamieson, C. H. M., Jones, D. L., Visvader, J., Weissman, I. L., & Wahl, G. M. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-3126 · Cited by 3,051
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Tumour heterogeneity and cancer cell plasticity
Meacham, C. E., & Morrison, S. J. (2013) · Nature · doi:10.1038/nature12624 · Cited by 2,446
Tankyrase inhibition stabilizes axin and antagonizes Wnt signalling
Huang, S.-M. A., Mishina, Y. M., Liu, S., Cheung, A., Stegmeier, F., Michaud, G. A., Charlat, O., Wiellette, E., Zhang, Y., Wiessner, S., et al. (2009) · Nature · doi:10.1038/nature08356 · Cited by 2,037
WNT signalling pathways as therapeutic targets in cancer
Anastas, J. N., & Moon, R. T. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3419 · Cited by 1,911
Wnt signalling and its impact on development and cancer
Klaus, A., & Birchmeier, W. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2389 · Cited by 1,595
Bissell, M. J., & Hines, W. C. (2011) · Nature Medicine · doi:10.1038/nm.2328 · Cited by 1,517
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963
Ability of polymorphonuclear leukocytes to orient in gradients of chemotactic factors.
Zigmond, S. H. (1977) · The Journal of cell biology · doi:10.1083/jcb.75.2.606 · Cited by 907
Roussos, E. T., Condeelis, J. S., & Patsialou, A. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3078 · Cited by 896
Mechanism of shape determination in motile cells
Keren, K., Pincus, Z., Allen, G. M., Barnhart, E. L., Marriott, G., Mogilner, A., & Theriot, J. A. (2008) · Nature · doi:10.1038/nature06952 · Cited by 719
Wnt signaling in stem and cancer stem cells
Holland, J. D., Klaus, A., Garratt, A. N., & Birchmeier, W. (2013) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2013.01.004 · Cited by 504
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Self-citationA hydrogel-based microfluidic device for the studies of directed cell migration
Cheng, S.-Y., Heilman, S., Wasserman, M., Archer, S., Shuler, M. L., & Wu, M. (2007) · Lab on a Chip · doi:10.1039/b618463d · Cited by 359
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Differential effects of EGF gradient profiles on MDA-MB-231 breast cancer cell chemotaxis
Wang, S.-J., Saadi, W., Lin, F., Minh-Canh Nguyen, C., & Li Jeon, N. (2004) · Experimental Cell Research · doi:10.1016/j.yexcr.2004.06.030 · Cited by 277
WNT Signaling in Lung Disease: A Failure or a Regeneration Signal?
Königshoff, M., & Eickelberg, O. (2010) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2008-0485tr · Cited by 258
Microfluidic single cell analysis: from promise to practice
Lecault, V., White, A. K., Singhal, A., & Hansen, C. L. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.03.022 · Cited by 229
Generation of dynamic temporal and spatial concentration gradients using microfluidic devices
Lin, F., Saadi, W., Rhee, S. W., Wang, S.-J., Mittal, S., & Jeon, N. L. (2004) · Lab on a Chip · doi:10.1039/b313600k · Cited by 222
Saadi, W., Rhee, S. W., Lin, F., Vahidi, B., Chung, B. G., & Jeon, N. L. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9051-9 · Cited by 194
Liu, L., Zhu, X.-D., Wang, W.-Q., Shen, Y., Qin, Y., Ren, Z.-G., Sun, H.-C., & Tang, Z.-Y. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-2610 · Cited by 183
Yang, M., Li, C.-W., & Yang, J. (2002) · Analytical Chemistry · doi:10.1021/ac025536c · Cited by 182
Self-citationA microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime
Zhang, Q., Liu, T., & Qin, J. (2012) · Lab on a Chip · doi:10.1039/c2lc00030j · Cited by 151
Polar stimulation and constrained cell migration in microfluidic channels
Irimia, D., Charras, G., Agrawal, N., Mitchison, T. J., & Toner, M. (2007) · Lab on a Chip · doi:10.1039/b710524j · Cited by 149
Microfluidic devices for studying chemotaxis and electrotaxis
Li, J., & Lin, F. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.05.002 · Cited by 148
Recent developments in microfluidics-based chemotaxis studies
Wu, J., Wu, X., & Lin, F. (2013) · Lab on a Chip · doi:10.1039/c3lc50415h · Cited by 138
Chemotaxis of Cell Populations through Confined Spaces at Single-Cell Resolution
Tong, Z., Balzer, E. M., Dallas, M. R., Hung, W.-C., Stebe, K. J., & Konstantopoulos, K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029211 · Cited by 138
Metabolism addiction in pancreatic cancer
Blum, R., & Kloog, Y. (2014) · Cell Death & Disease · doi:10.1038/cddis.2014.38 · Cited by 134
Modelling cell motility and chemotaxis with evolving surface finite elements
Elliott, C. M., Stinner, B., & Venkataraman, C. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0276 · Cited by 124
Nuclear deformation during breast cancer cell transmigration
Fu, Y., Chin, L. K., Bourouina, T., Liu, A. Q., & VanDongen, A. M. J. (2012) · Lab on a Chip · doi:10.1039/c2lc40477j · Cited by 115
Microfluidics-based devices: New tools for studying cancer and cancer stem cell migration
Huang, Y., Agrawal, B., Sun, D., Kuo, J. S., & Williams, J. C. (2011) · Biomicrofluidics · doi:10.1063/1.3555195 · Cited by 105
Guturi, K. K. N., Mandal, T., Chatterjee, A., Sarkar, M., Bhattacharya, S., Chatterjee, U., & Ghosh, M. K. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.324798 · Cited by 65
Nishioka, T., Kim, H., Luo, L.-Y., Huang, Y., Guo, J., & Chen, C. Y. (2011) · Breast Cancer Research · doi:10.1186/bcr3055 · Cited by 65
A hybrid microfluidic-vacuum device for direct interfacing with conventional cell culture methods
Chung, B. G., Park, J. W., Hu, J. S., Huang, C. P., Monuki, E. S., & Jeon, N. L. (2007) · BMC Biotechnology · doi:10.1186/1472-6750-7-60 · Cited by 57
Li, C., Chen, R., & Yang, M. (2007) · Lab on a Chip · doi:10.1039/b705525k · Cited by 52
Self-citationA new chemotaxis device for cell migration studies
Raja, W. K., Gligorijevic, B., Wyckoff, J., Condeelis, J. S., & Castracane, J. (2010) · Integrative Biology · doi:10.1039/c0ib00044b · Cited by 42
Dose-dependent cell-based assays in V-shaped microfluidic channels
Li, C., Yang, J., & Yang, M. (2006) · Lab on a Chip · doi:10.1039/b600058d · Cited by 37
Self-citationA compact microfluidic gradient generator using passive pumping
Gao, Y., Sun, J., Lin, W., Webb, D. J., & Li, D. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0908-0 · Cited by 36
Growth-factor-dependent migration of human lung-cancer cells
Bredin, C. G., Liu, Z., Hauzenberger, D., & Klominek, J. (1999) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19990730)82:3<338::aid-ijc6>3.0.co;2-y · Cited by 30
Yue, W., Li, C., Xu, T., & Yang, M. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.09.046 · Cited by 28
Self-citationXu, T., Yue, W., Li, C., Yao, X., & Yang, M. (2013) · Lab on a Chip · doi:10.1039/c3lc40880a · Cited by 26
Self-citationXu, T., Li, C., Yao, X., Cai, G., & Yang, M. (2009) · Analytical Biochemistry · doi:10.1016/j.ab.2009.09.018 · Cited by 24
Self-citationRecent Developments in Microfluidic Chip-Based Separation Devices Coupled to MS for Bioanalysis
Lin, S., Lin, T., & Fuh, M. (2013) · Bioanalysis · doi:10.4155/bio.13.196 · Cited by 20
Fok, S., Rubin, J. S., Pixley, F. J., Condeelis, J. S., Braet, F., & Soon, L. (2006) · BMC Cancer · doi:10.1186/1471-2407-6-151 · Cited by 18
Jang, C., & Arany, Z. P. (2013) · Nature · doi:10.1038/nature12549 · Cited by 13
Yue, W., Li, C., Xu, T., & Yang, M. (2011) · Lab on a Chip · doi:10.1039/c1lc20446g · Cited by 12
Self-citationThérapies ciblées et radiothérapie dans les cancers bronchiques non à petites cellules
Rivera, S., Quéro, L., Kam, S. W. H., Maylin, C., Deutsch, É., & Hennequin, C. (2011) · Cancer/Radiothérapie · doi:10.1016/j.canrad.2011.07.234 · Cited by 8
Rivera, S., Rivera, C., Loriot, Y., Hennequin, C., Vozenin, M., & Deutsch, É. (2011) · Cancer/Radiothérapie · doi:10.1016/j.canrad.2011.03.003 · Cited by 4
Diffusion of rose bengal in agar gel: Variation with the concentration of the diffusant and the gel
Arnikar, H. J., & Tattitali, S. A. (1986) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/bf02163050 · Cited by 3
Research works printed but not linked: 2
- Li J., 2011, Trends. Cell. Biol., 21, 489, 10.1016/j.tcb.2011.05.002 · DOI
- Dexter, N. C.; Kruse, K. L.; Nutaro, J. J.; Ward, R. C.2009 First Annual OrnlBiomedical Science & Engineering Conference: Exploring the Intersections of Interdisciplinary Biomedical Research; 2009; pp76–79.
Cited by
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Inhibition of Glioma Cells’ Proliferation by Doxorubicin-Loaded Exosomes via Microfluidics
Thakur, A., Sidu, R. K., Zou, H., Alam, M. K., Yang, M., & Lee, Y. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s263956 · Cited by 160
Self-citationMicrofluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering
Perestrelo, A., Águas, A., Rainer, A., & Forte, G. (2015) · Sensors · doi:10.3390/s151229848 · Cited by 149
Multi-Organs-on-Chips: Towards Long-Term Biomedical Investigations
Zhao, Y., Kankala, R. K., Wang, S.-B., & Chen, A.-Z. (2019) · Molecules · doi:10.3390/molecules24040675 · Cited by 134
Alam, M. K., Koomson, E., Zou, H., Yi, C., Li, C., Xu, T., & Yang, M. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.054 · Cited by 133
Self-citation
Metadata
- Authors
- Zou, H., Yue, W., Yu, W.-K., Liu, D., Fong, C.-C., Zhao, J., & Yang, M.
- Affiliations
- City University of Hong Kong (HK)
- Chinese Academy of Sciences (CN)
- Corresponding author
- Yang, Mengsu
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-07-07
- Volume
- 87
- Issue
- 14
- Pages
- 7098-7108
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2343587637
- Semantic Scholar
- ca3e7b37035eeb4e09e6324929571d58a4007014
- Cited by
- 47
- References
- 51
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2023: 4 · 2022: 4 · 2021: 3 · 2020: 5 · 2019: 7 · 2018: 4 · 2017: 8 · 2016: 3 · 2015: 2
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Science Foundation of Guangdong Province (2014A030310282)
- State Key Laboratory of Environmental and Biological Analysis, Hong Kong Baptist University
- Research Grants Council of the Hong Kong (CityU9/CRF/13G)
- Strategic Development Fund, Hong Kong Baptist University (SKLP_14-15_P008)
- Shenzhen Municiple Government (JCYJ20140419115507575)
- Ministry of Science and Technology of the People's Republic of China (2012CB933302)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- chemotaxis, cancer stem cells, lung cancer stem cells, microfluidics, Wnt signaling, β-catenin, tumor heterogeneity, single-cell migration, metastasis, cell adhesion
- MeSH terms
- Cell Adhesion, Cell Differentiation, Cell Movement, Chemotaxis, Humans, Microscopy, Electron, Scanning, Neoplastic Stem Cells, Cell Line, Tumor, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.