Dopant Enriched Nitrogen Gas Combined with Sheathless Capillary Electrophoresis–Electrospray Ionization-Mass Spectrometry for Improved Sensitivity and Repeatability in Glycopeptide Analysis
The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Abstract
Over the last years, numerous strategies have been proposed to enhance both ionization efficiency and spray stability in electrospray ionization (ESI), in particular for nanospray applications. In nano-liquid chromatography-mass spectrometry (nano-LC-ESI-MS), a better ESI performance has been observed when a coaxial gas flow is added around the ESI emitter. Moreover, enrichment of the gas with an organic dopant has led to an improved desolvation and ionization efficiency with an overall enhanced sensitivity. In this study, the use of a dopant enriched nitrogen (DEN)-gas combined with sheathless capillary electrophoresis (CE)-ESI-MS was evaluated for glycopeptide analysis. Using acetonitrile as a dopant, an increased sensitivity was observed compared to conventional sheathless CE-ESI-MS. Up to 25-fold higher sensitivities for model glycopeptides were obtained, allowing for limits of detection unachieved by state-of-the-art nano-LC-ESI-MS. The effect of DEN-gas on the repeatability and intermediate precision was also investigated. When compared to previously reported nano-LC-ESI-MS measurements, similar values were found for CE-ESI-MS with DEN-gas. The enhanced repeatability fosters the use of DEN-gas sheathless CE-ESI-MS in protein glycosylation analysis, where precision is essential. The use of DEN-gas opens new avenues for highly sensitive sheathless CE-ESI-MS approaches in glycoproteomics research, by significantly improving sensitivity and precision.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The sheathless interface has been widely used in proteomics research to provide ultrasensitive analysis56–58, although it is limited by potential blocking of the pores.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [56]
Citations
Cites
Biological roles of oligosaccharides: all of the theories are correct
Varki, A. (1993) · Glycobiology · doi:10.1093/glycob/3.2.97 · Cited by 5,195
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Glycosylation as a strategy to improve antibody-based therapeutics
Jefferis, R. (2009) · Nature Reviews Drug Discovery · doi:10.1038/nrd2804 · Cited by 829
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Nanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415
Breadmore, M. C., Shallan, A. I., Rabanes, H. R., Gstoettenmayr, D., Abdul Keyon, A. S., Gaspar, A., Dawod, M., & Quirino, J. P. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200396 · Cited by 372
Moini, M. (2007) · Analytical Chemistry · doi:10.1021/ac0704560 · Cited by 322
Mysling, S., Palmisano, G., Højrup, P., & Thaysen-Andersen, M. (2010) · Analytical Chemistry · doi:10.1021/ac100530w · Cited by 298
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Gas-phase ions of solute species from charged droplets of solutions
Nguyen, S., & Fenn, J. B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609969104 · Cited by 232
Small volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Huffman, J. E., Pučić-Baković, M., Klarić, L., Hennig, R., Selman, M. H. J., Vučković, F., Novokmet, M., Krištić, J., Borowiak, M., Muth, T., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.037465 · Cited by 171
Self-citationBusnel, J.-M., Schoenmaker, B., Ramautar, R., Carrasco-Pancorbo, A., Ratnayake, C., Feitelson, J. S., Chapman, J. D., Deelder, A. M., & Mayboroda, O. A. (2010) · Analytical Chemistry · doi:10.1021/ac102159d · Cited by 165
Self-citationWang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Selman, M. H. J., Derks, R. J. E., Bondt, A., Palmblad, M., Schoenmaker, B., Koeleman, C. A. M., van de Geijn, F. E., Dolhain, R. J. E. M., Deelder, A. M., & Wuhrer, M. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.11.003 · Cited by 140
Self-citationTimerbaev, A. R., & Hirokawa, T. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500320 · Cited by 137
Hinneburg, H., Stavenhagen, K., Schweiger-Hufnagel, U., Pengelley, S., Jabs, W., Seeberger, P. H., Silva, D. V., Wuhrer, M., & Kolarich, D. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1308-6 · Cited by 136
Self-citationReusch, D., Haberger, M., Falck, D., Peter, B., Maier, B., Gassner, J., Hook, M., Wagner, K., Bonnington, L., Bulau, P., et al. (2015) · mAbs · doi:10.1080/19420862.2015.1045173 · Cited by 132
Self-citationBonvin, G., Schappler, J., & Rudaz, S. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.07.019 · Cited by 115
Jansen, B. C., Reiding, K. R., Bondt, A., Ederveen, A. L. H., Palmblad, M., Falck, D., & Wuhrer, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00658 · Cited by 110
Self-citationEhrmann, B. M., Henriksen, T., & Cech, N. B. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.01.003 · Cited by 102
Heemskerk, A. A. M., Busnel, J.-M., Schoenmaker, B., Derks, R. J. E., Klychnikov, O., Hensbergen, P. J., Deelder, A. M., & Mayboroda, O. A. (2012) · Analytical Chemistry · doi:10.1021/ac300641x · Cited by 100
Self-citationBladergroen, M. R., Reiding, K. R., Hipgrave Ederveen, A. L., Vreeker, G. C. M., Clerc, F., Holst, S., Bondt, A., Wuhrer, M., & van der Burgt, Y. E. M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00538 · Cited by 95
Self-citationGahoual, R., Busnel, J.-M., Beck, A., François, Y.-N., & Leize-Wagner, E. (2014) · Analytical Chemistry · doi:10.1021/ac502378e · Cited by 90
Sarg, B., Faserl, K., Kremser, L., Halfinger, B., Sebastiano, R., & Lindner, H. H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.024109 · Cited by 76
Meyer, J. G., & A. Komives, E. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0404-0 · Cited by 68
Peterman, S. M., & Mulholland, J. J. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.10.008 · Cited by 64
Sanz‐Nebot, V., Balaguer, E., Benavente, F., & Barbosa, J. (2005) · Electrophoresis · doi:10.1002/elps.200410087 · Cited by 61
Heemskerk, A. A. M., Wuhrer, M., Busnel, J., Koeleman, C. A. M., Selman, M. H. J., Vidarsson, G., Kapur, R., Schoenmaker, B., Derks, R. J. E., Deelder, A. M., et al. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200357 · Cited by 43
Self-citation
Research works printed but not linked: 1
- Bruker Daltonics Inc., 2013, CaptiveSpray nanoBooster: The Revolution in Proteomics Ionization
Cited by
Mass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Capillary Electrophoresis: Trends and Recent Advances
Voeten, R. L. C., Ventouri, I. K., Haselberg, R., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00015 · Cited by 315
Bagdonaite, I., Malaker, S. A., Polasky, D. A., Riley, N. M., Schjoldager, K., Vakhrushev, S. Y., Halim, A., Aoki-Kinoshita, K. F., Nesvizhskii, A. I., Bertozzi, C. R., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00128-4 · Cited by 251
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
The glycosylation in SARS-CoV-2 and its receptor ACE2
Gong, Y., Qin, S., Dai, L., & Tian, Z. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00809-8 · Cited by 210
Metadata
- Authors
- Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M.
- Affiliations
- Leiden University Medical Center, Center for Proteomics and Metabolomics, P.O. Box 9600, 2300 RC Leiden, The Netherlands
- Leiden University Medical Center (NL)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-05-12
- Volume
- 88
- Issue
- 11
- Pages
- 5849-5856
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2356420218
- Cited by
- 74
- References
- 30
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 6 · 2023: 7 · 2022: 7 · 2021: 14 · 2020: 7 · 2019: 8 · 2018: 9 · 2017: 6 · 2016: 1
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Leiden Repository (Leiden University) (submittedVersion)
- Funders
- Seventh Framework Programme (278535, 305479)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (93511033)
- Swiss National Science Foundation (P2GEP3_155633)
- AB Sciex Pte. Ltd.
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Glycosylation and Glycoproteins Research
- Keywords
- electrospray ionization, glycopeptide analysis, ionization efficiency, desolvation, sensitivity enhancement, repeatability, protein glycosylation, glycoproteomics
- MeSH terms
- Chromatography, Liquid, Glycopeptides, Nitrogen, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.