Open-Source Potentiostat for Wireless Electrochemical Detection with Smartphones
Open accessAbstract
This paper describes the design and characterization of an open-source "universal wireless electrochemical detector" (UWED). This detector interfaces with a smartphone (or a tablet) using "Bluetooth Low Energy" protocol; the smartphone provides (i) a user interface for receiving the experimental parameters from the user and visualizing the result in real time, and (ii) a proxy for storing, processing, and transmitting the data and experimental protocols. This approach simplifies the design, and decreases both the size and the cost of the hardware; it also makes the UWED adaptable to different types of analyses by simple modification of the software. The UWED can perform the most common electroanalytical techniques of potentiometry, chronoamperometry, cyclic voltammetry, and square wave voltammetry, with results closely comparable to benchtop commercial potentiostats. Although the operating ranges of electrical current and voltage of the UWED (±1.5 V, ±180 μA) are more limited than most benchtop commercial potentiostats, its functional range is sufficient for most electrochemical analyses in aqueous solutions. Because the UWED is simple, small in size, assembled from inexpensive components, and completely wireless, it offers new opportunities for the development of affordable diagnostics, sensors, and wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
A review on detection of heavy metal ions in water—An electrochemical approach
Gumpu, M. B., Sethuraman, S., Krishnan, U. M., & Rayappan, J. B. B. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.02.122 · Cited by 1,027
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2013) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 696
Supramolecular Chemistry: From Molecules to Nanomaterials
(2012) · Wiley eBooks · doi:10.1002/9780470661345 · Cited by 534
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Self-citationAdhesive RFID Sensor Patch for Monitoring of Sweat Electrolytes
Rose, D. P., Ratterman, M. E., Griffin, D. K., Hou, L., Kelley-Loughnane, N., Naik, R. R., Hagen, J. A., Papautsky, I., & Heikenfeld, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2369991 · Cited by 416
Electrochemical sensors for environmental monitoring: design, development and applications
Hanrahan, G., Patil, D. G., & Wang, J. (2004) · Journal of Environmental Monitoring · doi:10.1039/b403975k · Cited by 414
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 398
Tattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
Self-citationCheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational Applications
Rowe, A. A., Bonham, A. J., White, R. J., Zimmer, M. P., Yadgar, R. J., Hobza, T. M., Honea, J. W., Ben-Yaacov, I., & Plaxco, K. W. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023783 · Cited by 284
DNA electrochemical biosensors for environmental monitoring. A review
Wang, J., Rivas, G., Cai, X., Palecek, E., Nielsen, P., Shiraishi, H., Dontha, N., Luo, D., Parrado, C., Chicharro, M., et al. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(96)00598-3 · Cited by 283
Electronic Detection of Nucleic Acids
Umek, R. M., Lin, S. W., Vielmetter, J., Terbrueggen, R. H., Irvine, B., Yu, C. J., Kayyem, J. F., Yowanto, H., Blackburn, G. F., Farkas, D. H., et al. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60655-1 · Cited by 253
DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration
Dryden, M. D. M., & Wheeler, A. R. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140349 · Cited by 221
A Paper-Based “Pop-up” Electrochemical Device for Analysis of Beta-Hydroxybutyrate
Wang, C.-C., Hennek, J. W., Ainla, A., Kumar, A. A., Lan, W.-J., Im, J., Smith, B. S., Zhao, M., & Whitesides, G. M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00568 · Cited by 180
Self-citationA low-cost miniaturized potentiostat for point-of-care diagnosis
Cruz, A. F. D., Norena, N., Kaushik, A., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.053 · Cited by 165
Selvam, A. P., Muthukumar, S., Kamakoti, V., & Prasad, S. (2016) · Scientific Reports · doi:10.1038/srep23111 · Cited by 147
Sun, A. C., Yao, C., Venkatesh and, G., & Hall, D. A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.05.010 · Cited by 107
Upon the Shoulders of Giants: Open-Source Hardware and Software in Analytical Chemistry
Dryden, M. D. M., Fobel, R., Fobel, C., & Wheeler, A. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00485 · Cited by 97
Electrochemical Immunosensors for Food Analysis: A Review of Recent Developments
Duffy, G., & Moore, E. (2016) · Analytical Letters · doi:10.1080/00032719.2016.1167900 · Cited by 93
A wireless potentiostat for mobile chemical sensing and biosensing
Steinberg, M. D., Kassal, P., Kereković, I., & Steinberg, I. M. (2015) · Talanta · doi:10.1016/j.talanta.2015.05.028 · Cited by 84
Handheld isothermal amplification and electrochemical detection of DNA in resource-limited settings
Tsaloglou, M., Nemiroski, A., Camci‐Unal, G., Christodouleas, D. C., Murray, L. P., Connelly, J. T., & Whitesides, G. M. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2017.11.025 · Cited by 84
Self-citationGiordano, G. F., Vicentini, M. B. R., Murer, R. C., Augusto, F., Ferrão, M. F., Helfer, G. A., da Costa, A. B., Gobbi, Â. L., Hantao, L. W., & Lima, R. S. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.09.157 · Cited by 60
Research works printed but not linked: 8
- Mettakoonpitak, 2016, Electroanalysis, 28, 1420, 10.1002/elan.201501143 · doi:10.1002/elan.201501143
- Pedrero, 2014, Electroanalysis, 26, 1132, 10.1002/elan.201300597 · doi:10.1002/elan.201300597
- Christidis, 2006, Rev. Sci. Instrum., 77, 10.1063/1.2165570 · doi:10.1063/1.2165570
- Hwang, 2010, IEEE Sens. J., 10, 820, 10.1109/JSEN.2009.2035098 · doi:10.1109/jsen.2009.2035098
- Jeanneret, 2015, Sens. Actuators, B, 207, 631, 10.1016/j.snb.2014.10.084 · doi:10.1016/j.snb.2014.10.084
- Kappes, 1999, Anal. Chim. Acta, 393, 77, 10.1016/S0003-2670(99)00149-X · doi:10.1016/s0003-2670(99)00149-x
- Steinberg, 2004, Sens. Actuators, B, 97, 284, 10.1016/j.snb.2003.09.002 · doi:10.1016/j.snb.2003.09.002
- Dobbelaere, 2017, HardwareX, 2, 34, 10.1016/j.ohx.2017.08.001 · doi:10.1016/j.ohx.2017.08.001
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Self-citationDevice integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Electrochemical paper-based devices: sensing approaches and progress toward practical applications
Noviana, E., McCord, C. P., Clark, K. M., Jang, I., & Henry, C. S. (2020) · Lab on a Chip · doi:10.1039/c9lc00903e · Cited by 321
Screen-printed electrodes: Transitioning the laboratory in-to-the field
García-Miranda Ferrari, A., Rowley-Neale, S. J., & Banks, C. E. (2021) · Talanta Open · doi:10.1016/j.talo.2021.100032 · Cited by 315
Metadata
- Authors
- Ainla, A., Mousavi, M. P. S., Tsaloglou, M.-N., Redston, J., Bell, J. G., Fernández-Abedul, M. T., & Whitesides, G. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-16
- Volume
- 90
- Issue
- 10
- Pages
- 6240-6246
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2799735367
- Cited by
- 360
- References
- 28
- FWCI
- 18.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Funders
- Division of Materials Research (DMR-1420570)
- Defense Threat Reduction Agency (HDTRA1-14-C-0037)
- Bill and Melinda Gates Foundation (51308)
- FP7 People: Marie-Curie Actions (IOF-GA-2013-622879- ENVIRO)
- Vetenskapsrådet (International postdoctoral fellowship)
- Wyss Institute for Biologically Inspired Engineering, Harvard University (NA)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.