The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Exhaled CO 2 as a COVID-19 Infection Risk Proxy for Different Indoor Environments and Activities
Open accessAbstract
Abstract CO 2 is co-exhaled with aerosols containing SARS-CoV-2 by COVID-19 infected people and can be used as a proxy of SARS-CoV-2 concentrations indoors. Indoor CO 2 measurements by low-cost sensors hold promise for mass monitoring of indoor aerosol transmission risk for COVID-19 and other respiratory diseases. We derive analytical expressions of CO 2 -based risk proxies and apply them to various typical indoor environments. The relative infection risk in a given environment scales with excess CO 2 level, and thus keeping CO 2 as low as feasible in a space allows optimizing the protection provided by ventilation. We show that the CO 2 level corresponding to a given absolute infection risk varies by over 2 orders of magnitude for different environments and activities. Although large uncertainties, mainly from virus exhalation rates, are still associated with infection risk estimates, our study provides more specific and practical recommendations for low-cost CO 2 -based indoor infection risk monitoring. Table of Contents Graphic
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
Self-citationIt is time to address airborne transmission of coronavirus disease 2019 (COVID-19)
Morawska, L., & Milton, D. K. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa939 · Cited by 1,189
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
Reducing transmission of SARS-CoV-2
Prather, K. A., Wang, C. C., & Schooley, R. T. (2020) · Science · doi:10.1126/science.abc6197 · Cited by 850
Buonanno, G., Stabile, L., & Morawska, L. (2020) · Environment International · doi:10.1016/j.envint.2020.105794 · Cited by 780
Recognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Miller, S. L., Nazaroff, W. W., Jimenez, J. L., Boerstra, A., Buonanno, G., Dancer, S. J., Kurnitski, J., Marr, L. C., Morawska, L., & Noakes, C. (2021) · Indoor Air · doi:10.1111/ina.12751 · Cited by 734
Self-citationViable SARS-CoV-2 in the air of a hospital room with COVID-19 patients
Lednicky, J. A., Lauzardo, M., Fan, Z. H., Jutla, A., Tilly, T. B., Gangwar, M., Usmani, M., Shankar, S. N., Mohamed, K., Eiguren-Fernandez, A., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.09.025 · Cited by 683
Britton, T., Ball, F., & Trapman, P. (2020) · Science · doi:10.1126/science.abc6810 · Cited by 645
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Carbon dioxide generation rates for building occupants
Persily, A., & de Jonge, L. (2017) · Indoor Air · doi:10.1111/ina.12383 · Cited by 566
Indoor transmission of SARS‐CoV‐2
Qian, H., Miao, T., Liu, L., Zheng, X., Luo, D., & Li, Y. (2021) · Indoor Air · doi:10.1111/ina.12766 · Cited by 549
Buonanno, G., Morawska, L., & Stabile, L. (2020) · Environment International · doi:10.1016/j.envint.2020.106112 · Cited by 449
Airborne transmission of SARS-CoV-2
Prather, K. A., Marr, L. C., Schooley, R. T., McDiarmid, M. A., Wilson, M. E., & Milton, D. K. (2020) · Science · doi:10.1126/science.abf0521 · Cited by 400
Short-range airborne route dominates exposure of respiratory infection during close contact
Chen, W., Zhang, N., Wei, J., Yen, H.-L., & Li, Y. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106859 · Cited by 371
Tang, J. W., Bahnfleth, W. P., Bluyssen, P. M., Buonanno, G., Jimenez, J. L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., et al. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.12.022 · Cited by 350
Self-citationMa, J., Qi, X., Chen, H., Li, X., Zhang, Z., Wang, H., Sun, L., Zhang, L., Guo, J., Morawska, L., et al. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1283 · Cited by 337
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Ai, Z., Mak, C. M., Gao, N., & Niu, J. (2020) · Building Simulation · doi:10.1007/s12273-020-0614-5 · Cited by 188
Evaluation and environmental correction of ambient CO 2 measurements from a low-cost NDIR sensor
Martin, C. R., Zeng, N., Karion, A., Dickerson, R. R., Ren, X., Turpie, B. N., & Weber, K. J. (2017) · Atmospheric measurement techniques · doi:10.5194/amt-10-2383-2017 · Cited by 160
How to Safely Reopen Colleges and Universities During COVID-19: Experiences From Taiwan
Cheng, S., Wang, C.-H. J., Shen, A. C., & Chang, S. (2020) · Annals of Internal Medicine · doi:10.7326/m20-2927 · Cited by 131
Fromme, H., Heitmann, D., Dietrich, S., Schierl, R., Körner, W., Kiranoglu, M., Zapf, A., & Twardella, D. (2008) · Das Gesundheitswesen · doi:10.1055/s-2008-1046775 · Cited by 67
Save Kazakhstan's shrinking Lake Balkhash
Ussenaliyeva, D. A. A. (2020) · Science · doi:10.1126/science.abe7828 · Cited by 37
Air exchange rates from atmospheric CO2 daily cycle
Carrilho, J. D., Mateus, M., Batterman, S., & da Silva, M. G. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.01.062 · Cited by 25
Healthy Schools: Risk Reduction Strategies for Reopening Schools
Jones, E., Young, A., Clevenger, K. A., Salimifard, P., Wu, E., Luna, M. L., Lahvis, M., Lang, J., Bliss, M., Azimi, P., et al. (2020) · doi:10.13140/rg.2.2.22333.49127 · Cited by 22
Bond, T. C., Bosco‐Lauth, A. M., Farmer, D. K., Francisco, P. W., Pierce, J. R., Fedak, K. M., Ham, J. M., Jathar, S. H., & VandeWoude, S. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.0c07721 · Cited by 21
Cited by
Airborne transmission of respiratory viruses
Wang, C. C., Prather, K. A., Sznitman, J., Jimenez, J. L., Lakdawala, S. S., Tufekci, Z., & Marr, L. C. (2021) · Science · doi:10.1126/science.abd9149 · Cited by 1,543
Self-citationDevelopment and application of an indoor carbon dioxide metric
Persily, A. (2022) · Indoor Air · doi:10.1111/ina.13059 · Cited by 104
Metadata
- Authors
- Peng, Z., & Jimenez, J. L.
- Venue
- Environmental Science & Technology Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-04-05
- Volume
- 8
- Issue
- 5
- Pages
- 392-397
- ISSN
- 2328-8930 (ISSN-L)
- OpenAlex
- W3150212664
- Cited by
- 321
- References
- 27
- FWCI
- 34.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.