The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Screen-Printed PEDOT:PSS Electrodes on Commercial Finished Textiles for Electrocardiography
Abstract
Electrocardiography (ECG) is an essential technique for analyzing and monitoring cardiovascular physiological conditions such as arrhythmia. This article demonstrates the integration of screen-printed ECG circuitry from a commercially available conducting polymer, PEDOT:PSS, onto commercially available finished textiles. ECG signals were recorded in dry skin conditions due to the ability of PEDOT:PSS to function as both ionic and electronic conductors. The signal amplifies when the skin transpires water vapor or by applying a common lotion on the skin. Finally, PEDOT:PSS wires connected to PEDOT:PSS electrodes have been shown to record ECG signals comparable to Ag/AgCl connected to copper wires.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Cited by
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Highly conductive tissue-like hydrogel interface through template-directed assembly
Chong, J., Sung, C., Nam, K. S., Kang, T., Kim, H., Lee, H., Park, H., Park, S., & Kang, J. (2023) · Nature Communications · doi:10.1038/s41467-023-37948-1 · Cited by 286
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Niederhoffer, T., Vanhoestenberghe, A., & Lancashire, H. T. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb084 · Cited by 38
Metadata
- Authors
- Sinha, S. K., Noh, Y., Reljin, N., Treich, G. M., Hajeb-Mohammadalipour, S., Guo, Y., Chon, K. H., & Sotzing, G. A.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-23
- Volume
- 9
- Issue
- 43
- Pages
- 37524-37528
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2762666002
- Cited by
- 161
- References
- 4
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.