Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Mussel-Inspired Electroactive and Antioxidative Scaffolds with Incorporation of Polydopamine-Reduced Graphene Oxide for Enhancing Skin Wound Healing

Tang, Pengfei, Han, Lu, Li, Pengfei, Jia, Zhanrong, Wang, Kefeng, Zhang, Hongping, Tan, Hui, Guo, Tailin, Lu, Xiong·2019·ACS Applied Materials & Interfaces

Abstract

Wound repair and tissue regeneration are complex processes that involve many physiological signals. Thus, employing novel wound dressings with potent biological activity and physiological signal response ability to accelerate wound healing is a possible solution. Herein, inspired by mussel chemistry, we developed a polydopamine (PDA)-reduced graphene oxide (pGO)-incorporated chitosan (CS) and silk fibroin (SF) (pGO-CS/SF) scaffold with good mechanical, electroactive, and antioxidative properties as an efficient wound dressing. First, pGO with good dispersibility and cell affinity was obtained upon reduction by PDA under alkali conditions. Second, pGO was dispersed into a CS/SF mixture, and then CS and SF chains were dual-cross-linked by poly(ethylene glycol) diglycidyl ether and glutaraldehyde to obtain a pGO-incorporated gel. Finally, the gel underwent a freeze-dry process to obtain the pGO-CS/SF scaffold. Owing to PDA reduction and functionalization, pGO in the scaffold plays important roles for the performances of the scaffolds. First, the pGO acts as nanoreinforcement to enhance the mechanical properties of the scaffold by combining the dual-cross-linked CS/SF network. Second, the uniformly distributed pGO in the scaffolds comprises a well-connected electric pathway, which can provide a channel for the transmission of electrical signals in the scaffold. Moreover, pGO in the scaffolds serves as an antioxidant agent to scavenge reactive oxygen species (ROS) and therefore terminates excessive ROS oxidation. In vitro studies show that electroactive pGO-CS/SF scaffolds can respond to electrical signals and promote cytological behavior. In addition, the pGO-CS/SF scaffolds can reduce cellular oxidation by removing excessive ROS. The in vivo full-thickness skin defect model demonstrates that the electroactive and antioxidative pGO-CS/SF scaffold can efficiently enhance wound healing. In summary, the pGO-CS/SF scaffold is a promising wound dressing because of its ability to promote physiological electrical signal transmission for cell growth and reduce ROS oxidation, resulting in an improved wound regeneration effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.8b18931

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 243

Metadata

Authors
Tang, P., Han, L., Li, P., Jia, Z., Wang, K., Zhang, H., Tan, H., Guo, T., & Lu, X.
Venue
ACS Applied Materials & Interfaces
Published
2019-02-04
Volume
11
Issue
8
Pages
7703-7714
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2912366446
Cited by
243
References
4
FWCI
20.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.