Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 433

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Flexible, Tunable, and Ultrasensitive Capacitive Pressure Sensor with Microconformal Graphene Electrodes

Yang, Jun, Luo, Shi, Zhou, Xi, Li, Jialu, Fu, Jianting, Yang, Weidong, Wei, Dapeng·2019·ACS Applied Materials & Interfaces

Abstract

High-performance flexible pressure sensors are highly desirable in health monitoring, robotic tactile, and artificial intelligence. Construction of microstructures in dielectrics and electrodes is the dominating approach to improving the performance of capacitive pressure sensors. Herein, we have demonstrated a novel three-dimensional microconformal graphene electrode for ultrasensitive and tunable flexible capacitive pressure sensors. Because the fabrication process is controllable, the morphologies of the graphene that is perfectly conformal with the electrode are controllable consequently. Multiscale morphologies ranging from a few nanometers to hundreds of nanometers, even to tens of micrometers, have been systematically investigated, and the high-performance capacitive pressure sensor with high sensitivity (3.19 kPa –1 ), fast response (30 ms), ultralow detection limit (1 mg), tunable-sensitivity, high flexibility, and high stability was obtained. Furthermore, an ultrasensitivity of 7.68 kPa –1 was successfully achieved via symmetric double microconformal graphene electrodes. The finite element analysis indicates that the microstructured graphene electrode can enhance large deformation and thus effectively improve the sensitivity. Additionally, the proposed pressure sensors are demonstrated with practical applications including insect crawling detection, wearable health monitoring, and force feedback of robot tactile sensing with a sensor array. The microconformal graphene may provide a new approach to fabricating controllable microstructured electrodes to enhance the performance of capacitive pressure sensors and has great potential for innovative applications in wearable health-monitoring devices, robot tactile systems, and human–machine interface systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.9b02049

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 433

Metadata

Authors
Yang, J., Luo, S., Zhou, X., Li, J., Fu, J., Yang, W., & Wei, D.
Venue
ACS Applied Materials & Interfaces
Published
2019-03-14
Volume
11
Issue
16
Pages
14997-15006
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2921105756
Cited by
433
References
46
FWCI
16.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.