CoChat

Effect of Block Length and Stereocomplexation on the Thermally Processable Poly(ε-caprolactone) and Poly(Lactic acid) Block Copolymers for Biomedical Applications

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

The current research concentrates on the synthesis of linear block copolymers with their backbone consisting of hard and soft segments, that is, poly(L-lactic acid) (PLLA)/ poly(D-lactic acid) (PDLA) and poly(ε-caprolactone) (PCL), with the detailed investigation of the effect of block length on the thermal, mechanical, and crystallization behavior followed by their processing and biocompatibility evaluation. In the current work, sequential ring opening polymerization has been employed wherein PCL is used as a macroinitiator for the synthesis of diblock (PCL-PDLA and PCL-PLLA) and stereotriblock copolymers (PCL-PLLA-PDLA) of targeted molecular weight, which is confirmed by 1 H NMR spectroscopy. The block length of PCL, in the case of diblock copolymer, is fixed; however, that of PLLA or PDLA is varied, and the enantiomeric blends thereof are made to achieve the merits of stereocomplexation. The length of the individual blocks is the same in the case of stereotriblock copolymer. The presence of two crystalline domains is manifested from differential scanning calorimetry and thermogravimertric analysis. An interesting improvement in the mechanical properties is observed upon increasing the block length of PDLA/PLLA in the block copolymer system which may be ascribed to the confined crystalliztion of PCL in the microdomain structure. Additionally, the synthesized materials are found to support the adhesion of MG-63 (human bone osteoscarcoma) cells as determined from in vitro studies indicating their potential in bone repair and regeneration. Further, the block copolymers possessing superior mechanical properties are thermally processed by injection molding to fabricate representative orthopedic fixation devices such as cancellous and cortical bone screws. Eventually, the thermo-mechanical stability of the cancellous bone screw made from the synthesized block copolymer is presented as compared to that made from the commercial PLA at the sterilization temperature of the biomedical devices.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsapm.9b00789

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 41 references

Cited by

See all 28

Metadata

Authors
Mulchandani, N., Gupta, A., Masutani, K., Kumar, S., Sakurai, S., Kimura, Y., & Katiyar, V.
Affiliations
  • Indian Institute of Technology Guwahati (IN)
  • Kyoto Institute of Technology (JP)
Corresponding author
Katiyar, Vimal
Venue
ACS Applied Polymer Materials
Published
2019-10-30
Volume
1
Issue
12
Pages
3354-3365
ISSN
2637-6105 (ISSN-L)
OpenAlex
W2982557428
Cited by
28
References
41
Citations by year
2026: 4 · 2025: 6 · 2024: 3 · 2023: 6 · 2022: 4 · 2021: 4 · 2020: 1
FWCI
0.64
Type
journal article
Language
en
Open access
closed
Locations
ACS Applied Polymer Materials (publishedVersion)
Funders
  • Department of Science and Technology, Ministry of Science and Technology (IF 160861)
  • Department of Chemicals and Petrochemicals, Ministry of Chemicals and Fertilizers
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
Keywords
polycaprolactone, poly(L-lactic acid), poly(D-lactide), block copolymers, stereocomplexation, block length, macroinitiator, crystallization behavior, mechanical properties, biocompatibility, bone cell adhesion, bone regeneration, orthopedic fixation devices, bone screws, injection molding, thermal stability, sterilization, thermomechanical stability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.