Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Self-Powered Human-Health Monitoring through Aligned PVDF Nanofibers Interfaced Skin-Interactive Piezoelectric Sensor

Maity, Kuntal, Garain, Samiran, Henkel, Karsten, Schmeißer, Dieter, Mandal, Dipankar · 2020 · ACS Applied Polymer Materials

Abstract

Flexible and wearable e-skin sensors are attracting a great interest for their smart sensing applications in next-generation electronics. However, implant ability, sensitivity, and biosignal detection capability in a self-powered manner are the prime concerns in embedded devices. In particular, electrode compatibility and imperishability have become challenging issues in wearable sensors due to the poor compatibility and fragileness of metal electrodes. In this context, we report on a skin-interactive metal-free spongy electrode in a piezoelectric sensor where highly aligned poly(vinylidene fluoride) (PVDF) nanofibers (NFs) arrays are introduced as the piezoelectric active component and conducting polyaniline- (PANI-) coated PVDF (PANI–PVDF) NFs mats served as flexible electrodes. Notably, a 99% yield of piezoelectric phases of the aligned PVDF arrays is the key factor to exhibit promising mechano-sensitivity (0.8 V/kPa) performance that in turn helps in human-health monitoring. The sensor shows excellent mechanical to electrical energy conversion that enable to sense human finger touch (10 V under 10 kPa) with energy conversion efficiency of 53%. Most importantly, due to the compatible electrodes excellent mechanical stability has been found showing negligible degradation over 12,000 periodic cycles. Furthermore, under mechanical stimuli, it is also possible to charge up a capacitor (1 μF) to 4 V within 60 s confirming the possibility to use the device as a self-powered piezo-organic-e-skin sensor (POESS). This type of structural design enables to trace elusive movement of muscles and the operation in several conditions such as bending, compression and stretching. We demonstrated various human gestures monitoring, such as wrist bending, neck stretching, and arm compressions, throat movements during drinking water, coughing actions, and swallowing. In addition, diverse specific phonation recognition, heart-pulse measurement and its respective short-time Fourier transform (STFT) analysis indicate an efficient and convenient way of monitoring human-health status particularly in hospital-free mode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsapm.9b00846

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 232

Metadata

Authors
Maity, K., Garain, S., Henkel, K., Schmeißer, D., & Mandal, D.
Venue
ACS Applied Polymer Materials
Published
2020-01-16
Volume
2
Issue
2
Pages
862-878
ISSN
2637-6105 (ISSN-L)
OpenAlex
W3000340821
Cited by
232
References
9
FWCI
9.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.