The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
CO 2 Electroreduction from Carbonate Electrolyte
Open accessAbstract
The process of CO 2 valorization—from capture of CO 2 to its electrochemical upgrade—requires significant inputs in each of the capture, upgrade, and separation steps. Here we report an electrolyzer that upgrades carbonate electrolyte from CO 2 capture solution to syngas, achieving 100% carbon utilization across the system. A bipolar membrane is used to produce proton in situ to facilitate CO 2 release at the membrane:catalyst interface from the carbonate solution. Using a Ag catalyst, we generate syngas at a 3:1 H 2:CO ratio, and the product is not diluted by CO 2 at the gas outlet; we generate this pure syngas product stream at a current density of 150 mA/cm 2 and an energy efficiency of 35%. The carbonate-to-syngas system is stable under a continuous 145 h of catalytic operation. The work demonstrates the benefits of coupling CO 2 electrolysis with a CO 2 capture electrolyte on the path to practicable CO 2 conversion technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comprehensive review on PEM water electrolysis
Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.01.151 · Cited by 5,492
CO 2 electroreduction to ethylene via hydroxide-mediated copper catalysis at an abrupt interface
Dinh, C.-T., Burdyny, T., Kibria, M. G., Seifitokaldani, A., Gabardo, C. M., García de Arquer, F. P., Kiani, A., Edwards, J. P., De Luna, P., Bushuyev, O. S., et al. (2018) · Science · doi:10.1126/science.aas9100 · Cited by 2,515
Self-citationDirect Capture of CO2 from Ambient Air
Sanz-Pérez, E. S., Murdock, C. R., Didas, S. A., & Jones, C. W. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00173 · Cited by 2,406
KIRK-OTHMER ENCYCLOPEDIA OF CHEMICAL TECHNOLOGY
(1982) · Chemical & Engineering News Archive · doi:10.1021/cen-v060n014.ibc · Cited by 2,405
A Process for Capturing CO2 from the Atmosphere
Keith, D. W., Holmes, G., St. Angelo, D., & Heidel, K. (2018) · Joule · doi:10.1016/j.joule.2018.05.006 · Cited by 1,910
General Techno-Economic Analysis of CO 2 Electrolysis Systems
Jouny, M., Luc, W., & Jiao, F. (2018) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.7b03514 · Cited by 1,628
Separation of CO2 from Flue Gas: A Review
Aaron, D., & Tsouris, C. (2005) · Separation Science and Technology · doi:10.1081/ss-200042244 · Cited by 1,525
Burdyny, T., & Smith, W. A. (2019) · Energy & Environmental Science · doi:10.1039/c8ee03134g · Cited by 1,133
Hydrolysis of Electrolyte Cations Enhances the Electrochemical Reduction of CO 2 over Ag and Cu
Singh, M. R., Kwon, Y., Lum, Y., Ager, J. W., & Bell, A. T. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b07612 · Cited by 985
Self-citationVerma, S., Lu, S., & Kenis, P. J. A. (2019) · Nature Energy · doi:10.1038/s41560-019-0374-6 · Cited by 822
Reducing the Cost of CO 2 Capture from Flue Gases Using Pressure Swing Adsorption
Ho, M. T., Allinson, G. W., & Wiley, D. E. (2008) · Industrial & Engineering Chemistry Research · doi:10.1021/ie070831e · Cited by 566
Gupta, N., Gattrell, M., & MacDougall, B. (2006) · Journal of Applied Electrochemistry · doi:10.1007/s10800-005-9058-y · Cited by 558
Schreier, M., Héroguel, F., Steier, L., Ahmad, S., Luterbacher, J. S., Mayer, M. T., Luo, J., & Grätzel, M. (2017) · Nature Energy · doi:10.1038/nenergy.2017.87 · Cited by 542
Min, X., & Kanan, M. W. (2015) · Journal of the American Chemical Society · doi:10.1021/ja511890h · Cited by 541
Verma, S., Hamasaki, Y., Kim, C., Huang, W., Lu, S., Jhong, H.-R. M., Gewirth, A. A., Fujigaya, T., Nakashima, N., & Kenis, P. J. A. (2018) · ACS Energy Letters · doi:10.1021/acsenergylett.7b01096 · Cited by 521
Modeling gas-diffusion electrodes for CO2 reduction
Weng, L.-C., Bell, A. T., & Weber, A. Z. (2018) · Physical Chemistry Chemical Physics · doi:10.1039/c8cp01319e · Cited by 506
Verma, S., Lu, X., Ma, S., Masel, R. I., & Kenis, P. J. A. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp05665a · Cited by 497
A Highly Porous Copper Electrocatalyst for Carbon Dioxide Reduction
Lv, J., Jouny, M., Luc, W., Zhu, W., Zhu, J., & Jiao, F. (2018) · Advanced Materials · doi:10.1002/adma.201803111 · Cited by 497
Towards membrane-electrode assembly systems for CO2 reduction: a modeling study
Weng, L.-C., Bell, A. T., & Weber, A. Z. (2019) · Energy & Environmental Science · doi:10.1039/c9ee00909d · Cited by 452
“Deactivation of copper electrode” in electrochemical reduction of CO2
Hori, Y., Konishi, H., Futamura, T., Murata, A., Koga, O., Sakurai, H., & Oguma, K. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2005.03.015 · Cited by 431
Sustainion Imidazolium‐Functionalized Polymers for Carbon Dioxide Electrolysis
Kutz, R. B., Chen, Q., Yang, H., Sajjad, S. D., Liu, Z., & Masel, I. R. (2017) · Energy Technology · doi:10.1002/ente.201600636 · Cited by 427
Electrolysis of Gaseous CO2 to CO in a Flow Cell with a Bipolar Membrane
Salvatore, D. A., Weekes, D. M., He, J., Dettelbach, K. E., Li, Y. C., Mallouk, T. E., & Berlinguette, C. P. (2018) · ACS Energy Letters · doi:10.1021/acsenergylett.7b01017 · Cited by 349
Self-citationControlling H+ vs CO2 Reduction Selectivity on Pb Electrodes
Lee, C. H., & Kanan, M. W. (2015) · ACS Catalysis · doi:10.1021/cs5017672 · Cited by 341
Electrolysis of CO2 to Syngas in Bipolar Membrane-Based Electrochemical Cells
Li, Y. C., Zhou, D., Yan, Z., Gonçalves, R. H., Salvatore, D. A., Berlinguette, C. P., & Mallouk, T. E. (2016) · ACS Energy Letters · doi:10.1021/acsenergylett.6b00475 · Cited by 313
Self-citationMa, S., Luo, R., Gold, J. I., Yu, A. Z., Kim, B., & Kenis, P. J. A. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta00427j · Cited by 212
Bipolar Membrane‐Assisted Solar Water Splitting in Optimal pH
Luo, J., Vermaas, D. A., Bi, D., Hagfeldt, A., Smith, W. A., & Grätzel, M. (2016) · Advanced Energy Materials · doi:10.1002/aenm.201600100 · Cited by 205
Ramdin, M., Morrison, A. R. T., de Groen, M., van Haperen, R., de Kler, R., van den Broeke, L. J. P., Trusler, J. P. M., de Jong, W., & Vlugt, T. J. H. (2019) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.8b04944 · Cited by 197
Synergistic Electrochemical CO2 Reduction and Water Oxidation with a Bipolar Membrane
Vermaas, D. A., & Smith, W. A. (2016) · ACS Energy Letters · doi:10.1021/acsenergylett.6b00557 · Cited by 187
Bipolar Membranes Inhibit Product Crossover in CO2 Electrolysis Cells
Li, Y. C., Yan, Z., Hitt, J., Wycisk, R., Pintauro, P. N., & Mallouk, T. E. (2018) · Advanced Sustainable Systems · doi:10.1002/adsu.201700187 · Cited by 178
Self-citationYan, Z., Zhu, L., Li, Y. C., Wycisk, R. J., Pintauro, P. N., Hickner, M. A., & Mallouk, T. E. (2018) · Energy & Environmental Science · doi:10.1039/c8ee01192c · Cited by 175
Self-citationBoosting the Single-Pass Conversion for Renewable Chemical Electrosynthesis
Dinh, C., Li, Y., & Sargent, E. H. (2018) · Joule · doi:10.1016/j.joule.2018.10.021 · Cited by 77
Self-citationHo, A. S., Zhou, X., Han, L., Sullivan, I., Karp, C., Lewis, N. S., & Xiang, C. (2019) · ACS Energy Letters · doi:10.1021/acsenergylett.9b00278 · Cited by 50
Reiter, R. S., White, W., & Ardo, S. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0201604jes · Cited by 49
Reduced Graphene Oxide Bipolar Membranes for Integrated Solar Water Splitting in Optimal pH
McDonald, M. B., Bruce, J. P., McEleney, K., & Freund, M. S. (2015) · ChemSusChem · doi:10.1002/cssc.201500538 · Cited by 41
Cited by
Advanced Electrocatalysts with Single-Metal-Atom Active Sites
Wang, Y., Su, H., He, Y., Li, L., Zhu, S., Shen, H., Xie, P., Fu, X., Zhou, G., Feng, C., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00594 · Cited by 1,005
Self-citationCoupling electrochemical CO2 conversion with CO2 capture
Sullivan, I., Goryachev, A., Digdaya, I. A., Li, X., Atwater, H. A., Vermaas, D. A., & Xiang, C. (2021) · Nature Catalysis · doi:10.1038/s41929-021-00699-7 · Cited by 701
Gas diffusion electrodes and membranes for CO2 reduction electrolysers
Lees, E. W., Mowbray, B. A. W., Parlane, F. G. L., & Berlinguette, C. P. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00356-2 · Cited by 664
Accelerating water dissociation in bipolar membranes and for electrocatalysis
Oener, S. Z., Foster, M. J., & Boettcher, S. W. (2020) · Science · doi:10.1126/science.aaz1487 · Cited by 567
Electrochemical carbon dioxide capture to close the carbon cycle
Sharifian, R., Wagterveld, R. M., Digdaya, I. A., Xiang, C., & Vermaas, D. A. (2021) · Energy & Environmental Science · doi:10.1039/d0ee03382k · Cited by 514
Metadata
- Authors
- Li, Y. C., Lee, G., Yuan, T., Wang, Y., Nam, D.-H., Wang, Z., García de Arquer, F. P., Lum, Y., Dinh, C.-T., Voznyy, O., & Sargent, E. H.
- Venue
- ACS Energy Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-05-24
- Volume
- 4
- Issue
- 6
- Pages
- 1427-1431
- ISSN
- 2380-8195 (ISSN-L)
- OpenAlex
- W2945075429
- Cited by
- 282
- References
- 34
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.