High-Throughput, High-Multiplex Digital Protein Detection with Attomolar Sensitivity
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
A major challenge in many clinical diagnostic applications is the measurement of low-abundance proteins and other biomolecules in biological fluids. Digital technologies such as the digital enzyme-linked immunosorbent assay (ELISA) have enabled 1000-fold increases in sensitivity over conventional protein detection methods. However, current digital ELISA technologies still possess insufficient sensitivities for many rare protein biomarkers and require specialized instrumentation or time-consuming workflows that have limited their widespread implementation. To address these challenges, we have developed a more sensitive and streamlined digital ELISA platform, Molecular On-bead Signal Amplification for Individual Counting (MOSAIC), which attains low attomolar limits of detection, with an order of magnitude enhancement in sensitivity over these other methods. MOSAIC uses a rapid, automatable flow cytometric readout that vastly increases throughput and is easily integrated into existing laboratory infrastructure. As MOSAIC provides high sampling efficiencies for rare target molecules, assay bead number can readily be tuned to enhance signal-to-background with high measurement precision. Furthermore, the solution-based signal readout of MOSAIC expands the number of analytes that can simultaneously be measured for higher-order multiplexing with femtomolar sensitivities or below, compared with microwell- or droplet-based digital methods. As a proof of principle, we apply MOSAIC toward improving the detectability of low-abundance cytokines in saliva and ultrasensitive multiplexed measurements of eight protein analytes in plasma and saliva. The attomolar sensitivity, high throughput, and broad multiplexing abilities of MOSAIC provide highly accessible and versatile ultrasensitive capabilities that can potentially accelerate protein biomarker discovery and diagnostic testing for diverse disease applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Interleukin-10 and the Interleukin-10 Receptor
Moore, K. W., de Waal Malefyt, R., Coffman, R. L., & O'Garra, A. (2001) · Annual Review of Immunology · doi:10.1146/annurev.immunol.19.1.683 · Cited by 6,737
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationReynolds, D. (2009) · Encyclopedia of Biometrics · doi:10.1007/978-0-387-73003-5_196 · Cited by 1,875
Role of interleukin 10 transcriptional regulation in inflammation and autoimmune disease.
Iyer, S. S., & Cheng, G. (2012) · Critical Reviews™ in Immunology · doi:10.1615/critrevimmunol.v32.i1.30 · Cited by 1,611
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Self-citationCohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R. (2020) · ACS Nano · doi:10.1021/acsnano.0c02378 · Cited by 263
Self-citationYelleswarapu, V., Buser, J. R., Haber, M., Baron, J., Inapuri, E., & Issadore, D. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814110116 · Cited by 185
Single molecule enzyme-linked immunosorbent assays: Theoretical considerations
Chang, L., Rissin, D. M., Fournier, D. R., Piech, T., Patel, P. P., Wilson, D. H., & Duffy, D. C. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.02.011 · Cited by 185
Cited by
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Wu, C., Dougan, T. J., & Walt, D. R.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-01-14
- Volume
- 16
- Issue
- 1
- Pages
- 1025-1035
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4206227215
- Cited by
- 160
- References
- 26
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.