High-Throughput, High-Multiplex Digital Protein Detection with Attomolar Sensitivity
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
A major challenge in many clinical diagnostic applications is the measurement of low-abundance proteins and other biomolecules in biological fluids. Digital technologies such as the digital enzyme-linked immunosorbent assay (ELISA) have enabled 1000-fold increases in sensitivity over conventional protein detection methods. However, current digital ELISA technologies still possess insufficient sensitivities for many rare protein biomarkers and require specialized instrumentation or time-consuming workflows that have limited their widespread implementation. To address these challenges, we have developed a more sensitive and streamlined digital ELISA platform, Molecular On-bead Signal Amplification for Individual Counting (MOSAIC), which attains low attomolar limits of detection, with an order of magnitude enhancement in sensitivity over these other methods. MOSAIC uses a rapid, automatable flow cytometric readout that vastly increases throughput and is easily integrated into existing laboratory infrastructure. As MOSAIC provides high sampling efficiencies for rare target molecules, assay bead number can readily be tuned to enhance signal-to-background with high measurement precision. Furthermore, the solution-based signal readout of MOSAIC expands the number of analytes that can simultaneously be measured for higher-order multiplexing with femtomolar sensitivities or below, compared with microwell- or droplet-based digital methods. As a proof of principle, we apply MOSAIC toward improving the detectability of low-abundance cytokines in saliva and ultrasensitive multiplexed measurements of eight protein analytes in plasma and saliva. The attomolar sensitivity, high throughput, and broad multiplexing abilities of MOSAIC provide highly accessible and versatile ultrasensitive capabilities that can potentially accelerate protein biomarker discovery and diagnostic testing for diverse disease applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Interleukin-10 and the Interleukin-10 Receptor
Moore, K. W., de Waal Malefyt, R., Coffman, R. L., & O'Garra, A. (2001) · Annual Review of Immunology · doi:10.1146/annurev.immunol.19.1.683 · Cited by 6,737
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationReynolds, D. (2009) · Encyclopedia of Biometrics · doi:10.1007/978-0-387-73003-5_196 · Cited by 1,875
Role of interleukin 10 transcriptional regulation in inflammation and autoimmune disease.
Iyer, S. S., & Cheng, G. (2012) · Critical Reviews™ in Immunology · doi:10.1615/critrevimmunol.v32.i1.30 · Cited by 1,611
SERS-Activated Platforms for Immunoassay: Probes, Encoding Methods, and Applications
Wang, Z., Zong, S., Wu, L., Zhu, D., & Cui, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00027 · Cited by 614
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Self-citationCohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R. (2020) · ACS Nano · doi:10.1021/acsnano.0c02378 · Cited by 263
Self-citationYelleswarapu, V., Buser, J. R., Haber, M., Baron, J., Inapuri, E., & Issadore, D. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1814110116 · Cited by 185
Single molecule enzyme-linked immunosorbent assays: Theoretical considerations
Chang, L., Rissin, D. M., Fournier, D. R., Piech, T., Patel, P. P., Wilson, D. H., & Duffy, D. C. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.02.011 · Cited by 185
Ultrasensitive Detection of Attomolar Protein Concentrations by Dropcast Single Molecule Assays
Wu, C., Garden, P. M., & Walt, D. R. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c04331 · Cited by 176
Self-citationUltrasensitive high-resolution profiling of early seroconversion in patients with COVID-19
Norman, M., Gilboa, T., Ogata, A. F., Maley, A. M., Cohen, L., Busch, E. L., Lazarovits, R., Mao, C.-P., Cai, Y., Zhang, J., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00611-x · Cited by 142
Self-citationAkama, K., Shirai, K., & Suzuki, S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b01148 · Cited by 139
Kan, C. W., Tobos, C. I., Rissin, D. M., Wiener, A. D., Meyer, R. E., Svancara, D., Comperchio, A., Warwick, C., Millington, R. B., Collier, N., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00267d · Cited by 111
Extracellular Vesicle Analysis Allows for Identification of Invasive IPMN
Yang, K. S., Ciprani, D., O’Shea, A., Liss, A. S., Yang, R., Fletcher-Mercaldo, S., Mino-Kenudson, M. A., Castillo, C. F. F.-D., & Weissleder, R. (2020) · Gastroenterology · doi:10.1053/j.gastro.2020.11.046 · Cited by 103
A fully-automated, six-plex single molecule immunoassay for measuring cytokines in blood
Rivnak, A. J., Rissin, D. M., Kan, C. W., Song, L., Fishburn, M. W., Piech, T., Campbell, T. G., DuPont, D. R., Gardel, M., Sullivan, S., et al. (2015) · Journal of Immunological Methods · doi:10.1016/j.jim.2015.04.017 · Cited by 100
Maley, A. M., Garden, P. M., & Walt, D. R. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01661 · Cited by 79
Self-citationCritical Review: digital resolution biomolecular sensing for diagnostics and life science research
Huang, Q., Li, N., Zhang, H., Che, C., Sun, F., Xiong, Y., Canady, T. D., & Cunningham, B. T. (2020) · Lab on a Chip · doi:10.1039/d0lc00506a · Cited by 75
A rapid triage test for active pulmonary tuberculosis in adult patients with persistent cough
Ahmad, R., Xie, L., Pyle, M., Fernández-Suárez, M., Broger, T., Steinberg, D., Ame, S. M., Lucero, M., Szucs, M. J., MacMullan, M. A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw8287 · Cited by 73
Self-citationGünther, A., Becker, M., Göpfert, J. C., Joos, T. O., & Schneiderhan‐Marra, N. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.572634 · Cited by 53
Smith, L. D., Liu, Y., Zahid, M. U., Canady, T. D., Wang, L., Kohli, M., Cunningham, B. T., & Smith, A. M. (2020) · ACS Nano · doi:10.1021/acsnano.9b09498 · Cited by 40
The Teacher's Corner: More on Unbiased Estimation of the Standard Deviation
Bolch, B. W. (1968) · The American Statistician · doi:10.1080/00031305.1968.10480476 · Cited by 37
Gilboa, T., Maley, A. M., Ogata, A. F., Wu, C., & Walt, D. R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001111 · Cited by 27
Self-citationNorman, M., Gilboa, T., Ogata, A. F., Maley, A. M., Cohen, L., Cai, Y., Zhang, J., Feldman, J. E., Hauser, B. M., Caradonna, T. M., et al. (2020) · medRxiv · doi:10.1101/2020.04.28.20083691 · Cited by 26
Self-citationSingle-Molecule Arrays for Ultrasensitive Detection of Blood-Based Biomarkers for Immunotherapy
Cohen, L., Keegan, A., & Walt, D. R. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9773-2_18 · Cited by 13
Self-citationDing, M., Cavallin, A., Hermansson, N.-O., Berntsson, P., Jinton, L., & Blomqvist, S. R. (2018) · SLAS DISCOVERY · doi:10.1177/2472555218771610 · Cited by 13
Cited by
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Wu, C., Dougan, T. J., & Walt, D. R.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-01-14
- Volume
- 16
- Issue
- 1
- Pages
- 1025-1035
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W4206227215
- Cited by
- 160
- References
- 26
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.