Toward Self-Control Systems for Neurogenic Underactive Bladder: A Triboelectric Nanogenerator Sensor Integrated with a Bistable Micro-Actuator
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Aging, neurologic diseases, and diabetes are a few risk factors that may lead to underactive bladder (UAB) syndrome. Despite all of the serious consequences of UAB, current solutions, the most common being ureteric catheterization, are all accompanied by serious shortcomings. The necessity of multiple catheterizations per day for a physically able patient not only reduces the quality of life with constant discomfort and pain but also can end up causing serious complications. Here, we present a bistable actuator to empty the bladder by incorporating shape memory alloy components integrated on flexible polyvinyl chloride sheets. The introduction of two compression and restoration phases for the actuator allows for repeated actuation for a more complete voiding of the bladder. The proposed actuator exhibits one of the highest reported voiding percentages of up to 78% of the bladder volume in an anesthetized rat after only 20 s of actuation. This amount of voiding is comparable to the common catheterization method, and its one time implantation onto the bladder rectifies the drawbacks of multiple catheterizations per day. Furthermore, the scaling of the device for animal models larger than rats can be easily achieved by adjusting the number of nitinol springs. For neurogenic UAB patients with degraded nerve function as well as degenerated detrusor muscle, we integrate a flexible triboelectric nanogenerator sensor with the actuator to detect the fullness of the bladder. The sensitivity of this sensor to the filling status of the bladder shows its capability for defining a self-control system in the future that would allow autonomous micturition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hooton, T. M., Bradley, S. F., Cardenas, D. D., Colgan, R., Geerlings, S. E., Rice, J. C., Saint, S., Schaeffer, A. J., Tambayh, P. A., Tenke, P., et al. (2010) · Clinical Infectious Diseases · doi:10.1086/650482 · Cited by 2,099
Wang, Z. L. (2014) · Faraday Discuss. · doi:10.1039/c4fd00159a · Cited by 1,749
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Soft robotics: Technologies and systems pushing the boundaries of robot abilities
Laschi, C., Mazzolai, B., & Cianchetti, M. (2016) · Science Robotics · doi:10.1126/scirobotics.aah3690 · Cited by 1,570
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring
Lin, Z., Chen, J., Li, X., Zhou, Z., Meng, K., Wei, W., Yang, J., & Wang, Z. L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02975 · Cited by 494
Recent advances in flexible sensors for wearable and implantable devices
Pang, C., Lee, C., & Suh, K. (2013) · Journal of Applied Polymer Science · doi:10.1002/app.39461 · Cited by 457
Self-citationIn Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Cited by
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Wen, F., Sun, Z., He, T., Shi, Q., Zhu, M., Zhang, Z., Li, L., Zhang, T., & Lee, C. (2020) · Advanced Science · doi:10.1002/advs.202000261 · Cited by 478
Self-citationProgress in TENG technology—A journey from energy harvesting to nanoenergy and nanosystem
Zhu, J., Zhu, M., Shi, Q., Wen, F., Liu, L., Dong, B., Haroun, A., Yang, Y., Vachon, P., Guo, X., et al. (2020) · EcoMat · doi:10.1002/eom2.12058 · Cited by 370
Self-citationEmerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
Yao, S., Ren, P., Song, R., Liu, Y., Huang, Q., Dong, J., O'Connor, B. T., & Zhu, Y. (2020) · Advanced Materials · doi:10.1002/adma.201902343 · Cited by 324
Metadata
- Authors
- Arab Hassani, F., Mogan, R. P., Gammad, G. G. L., Wang, H., Yen, S.-C., Thakor, N. V., & Lee, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-04-09
- Volume
- 12
- Issue
- 4
- Pages
- 3487-3501
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2798031270
- Cited by
- 125
- References
- 12
- FWCI
- 16.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.