The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Bioinspired Ultrasensitive and Stretchable MXene-Based Strain Sensor via Nacre-Mimetic Microscale “Brick-and-Mortar” Architecture
Abstract
The development of wearable strain sensors with simultaneous large stretchability (strain >55%) and high sensitivity (gauge factor >100) remains a grand challenge to this day. Drawing on inspiration from nature, nacre has demonstrated outstanding mechanical properties, especially combining high strength and toughness, which is due in part to its delicate hierarchical layered architecture with rich interfacial interactions. We demonstrate that strain sensors based on this nacre-mimetic microscale “brick-and-mortar” architecture can simultaneously achieve ultrahigh sensitivity and large stretchability while performing well in linearity, reliability, long-term durability, and monotonicity. The bioinspired sensor demonstrated a gauge factor >200 over a range of working strains up to 83% and achieved a high gauge factor exceeding 8700 in the strain region of 76–83%. This successful combination of high sensitivity and large stretchability is attributed to (1) the microscale hierarchical architecture derived from the amalgamation of 2D titanium carbide (MXene) Ti 3 C 2 T x /1D silver nanowire “brick” and poly(dopamine)/Ni 2+ “mortar” and (2) the synergistic toughing effects from interfacial interactions of hydrogen and coordination bonding, layer slippage, and molecular chain stretching. The synergistic behavior of the “brick” and “mortar” allows for controlled crack generation for high sensitivity but can also dissipate considerable loading energy to promote the stepwise propagation of cracks while stretching, guaranteeing the significant comprehensive sensing performance. Moreover, this bioinspired strain sensor is employed to monitor human activities under different motion states to demonstrate its feasibility for wearable, full-spectrum human health and motion monitoring systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mussel-inspired surface chemistry for multifunctional coatings
Lee, H., Dellatore, S. M., Miller, W. M., & Messersmith, P. B. (2007) · Science · doi:10.1126/science.1147241 · Cited by 10,965
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Highly Stretchable Piezoresistive Graphene–Nanocellulose Nanopaper for Strain Sensors
Yan, C., Wang, J., Kang, W., Cui, M., Wang, X., Foo, C. Y., Chee, K. J., & Lee, P. S. (2014) · Advanced Materials · doi:10.1002/adma.201304742 · Cited by 1,179
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Kim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01505 · Cited by 626
Liu, Q., Chen, J., Li, Y., & Shi, G. (2016) · ACS Nano · doi:10.1021/acsnano.6b03813 · Cited by 609
Graphene Textile Strain Sensor with Negative Resistance Variation for Human Motion Detection
Yang, Z., Pang, Y., Han, X.-L., Yang, Y., Ling, J., Jian, M., Zhang, Y., Yang, Y., & Ren, T.-L. (2018) · ACS Nano · doi:10.1021/acsnano.8b03391 · Cited by 563
Cited by
Jiang, X., Kuklin, A. V., Baev, A., Ge, Y., Ågren, H., Zhang, H., & Prasad, P. N. (2020) · Physics Reports · doi:10.1016/j.physrep.2019.12.006 · Cited by 914
Flexible MXene‐Based Composites for Wearable Devices
Ma, C., Ma, M., Si, C., Ji, X., & Wan, P. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009524 · Cited by 544
Sensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
Recent Advances in Functional 2D MXene‐Based Nanostructures for Next‐Generation Devices
Huang, W., Hu, L., Tang, Y., Xie, Z., & Zhang, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005223 · Cited by 359
MXenes and Their Applications in Wearable Sensors
Xin, M., Li, J., Ma, Z., Pan, L., & Shi, Y. (2020) · Frontiers in Chemistry · doi:10.3389/fchem.2020.00297 · Cited by 246
Metadata
- Authors
- Shi, X., Wang, H., Xie, X., Xue, Q., Zhang, J., Kang, S., Wang, C., Liang, J., & Chen, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-12-19
- Volume
- 13
- Issue
- 1
- Pages
- 649-659
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2904858388
- Cited by
- 453
- References
- 9
- FWCI
- 13.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.