Soft, Skin-Integrated Multifunctional Microfluidic Systems for Accurate Colorimetric Analysis of Sweat Biomarkers and Temperature
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Real-time measurements of the total loss of sweat, the rate of sweating, the temperature of sweat, and the concentrations of electrolytes and metabolites in sweat can provide important insights into human physiology. Conventional methods use manual collection processes (e.g., absorbent pads) to determine sweat loss and lab-based instrumentation to analyze its chemical composition. Although such schemes can yield accurate data, they cannot be used outside of laboratories or clinics. Recently reported wearable electrochemical devices for sweat sensing bypass these limitations, but they typically involve on-board electronics, electrodes, and/or batteries for measurement, signal processing, and wireless transmission, without direct means for measuring sweat loss or capturing and storing small volumes of sweat. Alternative approaches exploit soft, skin-integrated microfluidic systems for collection and colorimetric chemical techniques for analysis. Here, we present the most advanced platforms of this type, in which optimized chemistries, microfluidic designs, and device layouts enable accurate assessments not only of total loss of sweat and sweat rate but also of quantitatively accurate values of the pH and temperature of sweat, and of the concentrations of chloride, glucose, and lactate across physiologically relevant ranges. Color calibration markings integrated into a graphics overlayer allow precise readout by digital image analysis, applicable in various lighting conditions. Field studies conducted on healthy volunteers demonstrate the full capabilities in measuring sweat loss/rate and analyzing multiple sweat biomarkers and temperature, with performance that quantitatively matches that of conventional lab-based measurement systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, some optical temperature sensors use infrared (IR) thermography[218] and colorimetric techniques with thermochromic liquid crystals that can be used to record the temperature more intuitively[219] and have already been applied to measure the temperature of the human body.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [219]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationA stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Self-citationBariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationUltrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Self-citationLee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Farrell, P. M., Rosenstein, B. J., White, T. B., Accurso, F. J., Castellani, C., Cutting, G. R., Durie, P. R., LeGrys, V. A., Massie, J., Parad, R. B., et al. (2008) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2008.05.005 · Cited by 1,094
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citation
Research works printed but not linked: 2
- Polliack A., 1997, J. Rehabil. Res. Dev, 34, 303
- 10.1089/dia.2011.0262 · DOI · Paper page
Cited by
Items 301–373 of 373
Song, R., Cho, S., Kim, G., Shin, S., Yin, S., Liu, R., Zeng, R., Tu, J., Xiong, Y., Park, I., et al. (2026) · Device · doi:10.1016/j.device.2026.101107 · Cited by 5
“Sweat is passively guided to each sensing reservoir by a series of CBVs, 12,21,32 whose geometry was tuned to achieve sequential filling, unidirectional flow, and prevention of cross-contamination (Figure 2E).”
Jalali, P., & Sanati‐Nezhad, A. (2026) · Lab on a Chip · doi:10.1039/d5lc01172h · Cited by 4
A yarn/fabric-based microfluidic patch for sweat sensing and monitoring
Wenze, Y., Li, Q., Zhao, Z., Gong, J., Li, Z., & Zhang, J. (2023) · Journal of the Textile Institute · doi:10.1080/00405000.2023.2288357 · Cited by 5
“…methods because of its simple design, low cost, good flexibility and better wearability of using microfluidic systems for sensor platforms (Choi et al., 2019; Promphet et al., 2019; Tu et al., 2020; Vaquer et al., 2021; L. Wang, Xu, et al., 2021; Y. Zhang et al., 2019; K. Zhang et al.,…”
Optical technologies for multiparametric heart failure management beyond the hospital
Vidal, M., Assunção, A. S., Bastos, J. M., Pereira, S. O., Segerink, L. I., Morrin, A., & Leitão, C. (2025) · Talanta · doi:10.1016/j.talanta.2025.128640 · Cited by 4
Lee, S., Song, H., Kim, J., Choi, G., Kim, J. S., Park, S., Jang, H., Kim, J., & Jeong, H. E. (2025) · Advanced Science · doi:10.1002/advs.202513259 · Cited by 5
Wells, P. K., Melman, A., Katz, E., & Smutok, O. V. (2022) · Microchimica Acta · doi:10.1007/s00604-022-05466-4 · Cited by 4
“The smartphones with minimum adaptation might be integrated with various biosensors [4, 5, 6, 7, 8, 9, 10] (see additional references in the Supporting Information) including glucose biosensors [11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22]) and with almost zero changes they can be used for processing optical signal…”
BackgroundCurrent Trends in the Development of Electrochemical Biosensor for Detecting Analytes from Sweat
Singh, A., Sharma, A., Dubey, A., & Arya, S. K. (2023) · Current Medicinal Chemistry · doi:10.2174/0929867331666230807143639 · Cited by 4
Sensing Interfaces: Materials for Wearable Sensors
de Lima, L. F., Ferreira, A. L., & de Araujo, W. R. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00127-8 · Cited by 4
Panicker, L. R., Keerthanaa, M. R., Sukumaran, R. A., Lakavath, K., & Kotagiri, Y. G. (2024) · Springer eBooks · doi:10.1007/978-981-97-5473-1_13 · Cited by 4
Liang, C., Zhang, H., Zhang, Z., Wang, L., Lin, X., Fu, Y., Zhu, X., Zhu, S., & Liu, J. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.114302 · Cited by 4
Chen, Y., Liu, P., Wang, F., Qi, Y., Xiong, X., & Liu, Y. (2025) · Analytical Methods · doi:10.1039/d5ay01723h · Cited by 3
Wearable biofluids colorimetric biosensors
Lyu, Z., Xiao, Z., Shen, W., Liu, C., Gu, T., Cao, R., Zhang, F., Meng, C., & Ding, S. (2026) · FlexMat. · doi:10.1002/flm2.70081 · Cited by 3
Recent advances in point-of-care colorimetric biosensors for detecting small molecule metabolites
朱志强, Gu, Z., Cao, X., Zhang, S., & Su, S. (2026) · Chemical Communications · doi:10.1039/d6cc02166b · Cited by 4
Romanholo, P. V. V., Andrade, L. M., Giglioti, M., Luccas, G. Z. A., Machado, S. A. S., & Sgobbi, L. F. (2025) · Microchimica Acta · doi:10.1007/s00604-025-07194-x · Cited by 3
“…multiplexed or hybrid approaches to detect and quantify several targets, including biomolecules [11], multiple ions [12], biomarkers [13, 14], and even combinations of chemical/biological detection with physiological data, such as cardiac output [15], body temperature [16], and movement [17].”
Wearable textile-based sensor for sweat sodium chloride monitoring applications
Zafar, H., Kumar, P., Jeoti, V., & Stojanović, G. M. (2025) · Journal of the Textile Institute · doi:10.1080/00405000.2025.2501368 · Cited by 3
“Body fluids are full of enriched information to analyze human health and daily physiology (Abell � an-Llobregat et al., 2017; Anastasova et al., 2017; Bandodkar et al., 2019, Choi et al., 2019; Glennon et al., 2016; Zafar et al., 2022).”
Ranta-Lassila, A., Le, D. H., Sipola, T., Karppinen, M., Petäjä, J., Kehusmaa, M., Aikio, S. M., Guo, T., Roussey, M., Hiltunen, J. A., et al. (2024) · SPIE Nanophotonics · doi:10.1117/12.3017594 · Cited by 3
Microfluidic Technologies for Precise Drug Delivery
Ferreira, B., Faria, P., Viegas, J. S. R., Sarmento, B. F. C. C., & Martins, C. (2024) · AAPS introductions in the pharmaceutical sciences · doi:10.1007/978-3-031-60717-2_13 · Cited by 3
Stress biomarker detection with a grating-coupled surface plasmon resonance sensor
Ranta-Lassila, A., Le, D. H., Sipola, T., Karppinen, M., Petäjä, J., Kehusmaa, M., Aikio, S. M., Guo, T., Roussey, M., Hiltunen, J. A., et al. (2024) · Optical Engineering · doi:10.1117/1.oe.63.11.117103 · Cited by 3
Wearable and flexible biomimetic microfluidic sensors for rapid sweat biomarker detection
Du, C., Liao, C., Li, S., Yang, C., Yao, H., Li, Y., & Liu, Y. (2025) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2025.115243 · Cited by 3
Mo, Q., Huang, Z., Luo, Z., Lin, F., Li, B., Xu, H., Sun, Y., Song, J., Weng, X., Liu, L., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139446 · Cited by 3
Lee, S. G., & Zarei, M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823727-4.00011-0 · Cited by 2
Measurement of Temperature in Parallel Channel of Microfluidic Reactors
Abdullah, A., Regnier, M., & Kopecký, D. (2024) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps61194.2024.10603875 · Cited by 2
“Although many studies have been carried out on the measurement and calibration of temperature in microfluidic devices [5,6], a unified and systematic theory is still lacking.”
BackgroundYazlık, E. N., & Saraçoğlu, Ö. G. (2024) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119241266375 · Cited by 2
Noninvasive Vital Signs Monitoring in the Neonatal Intensive Care Unit
Qian, C., Li, J., & Khine, M. (2024) · Journal of Biomedical Research & Environmental Sciences · doi:10.37871/jbres1958 · Cited by 2
Wearable Transdermal Biosensors
Rao, G., Srinivasan, V., Sheffield, Z., Ahuja, P., Kumar, S., Ge, X., Dighe, K., & Sundberg, C. A. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_5 · Cited by 3
Optical Sensors in Medical Diagnosis
Costa-Fernandez, J. M., Melendreras, C., & Soldado, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00153-9 · Cited by 2
Ohashi, K., & Ōsaka, T. (2023) · Journal of The Surface Finishing Society of Japan · doi:10.4139/sfj.74.43 · Cited by 1
Optimize Performance Using A Hydration Biosensor
Fu, J., Chen, N., & Mohamdee, A. (2024) · Aging and (Geron) Technology · doi:10.24908/agt.v2i1.17204 · Cited by 1
A Flexible Wearable Microsystem for Electrochemically Sensing Uric Acid from Sweat
Wang, J., Sun, J., Wang, X., Qiu, B., Han, X., Li, C., & Ding, W. (2025) · Analysis & Sensing · doi:10.1002/anse.202500102 · Cited by 7
Biomaterial‐Based Colorimetric Sensors for Continuous Temperature Monitoring
Ruggeri, E., Matzeu, G., Vergine, A., Presti, M. L., Guidetti, G., & Omenetto, F. G. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500624 · Cited by 1
Liu, C., Wang, Y., Wang, Q., Zhao, W., Li, Z., Wang, Q., Li, K., Sun, X., & Zhang, S. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.115314 · Cited by 2
Recent advances in wearable sensor technology for sweat analysis
Jacob, J., Niranjan, D. B., Sharma, A., Jayakrishnan, S., Jose, R. C., Medikonda, J., Peter, M., & Namboothiri, P. K. (2026) · Discover Applied Sciences · doi:10.1007/s42452-026-08404-8 · Cited by 3
Jarnda, K. V., Dai, H., Hu, H., Tian, Y., Anaman, R., Wu, P., & Ding, P. (2026) · ACS Omega · doi:10.1021/acsomega.5c10036 · Cited by 1
Liu, D., Chen, Y., Li, X., Zhou, W., & Zhang, C. (2026) · Journal of Future Foods · doi:10.1016/j.jfutfo.2026.03.018 · Cited by 1
Zhang, D., Zhang, J., Jing, Q., Jeswani, R., Wade, T., & Kar‐Narayan, S. (2026) · APL Electronic Devices · doi:10.1063/5.0320597 · Cited by 1
Tonello, S., Hosseinzadeh, B., Lopomo, N. F., & Sardini, E. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3709497 · Cited by 1
“…these limitations, emerging technologies—including microfluidics / millifluidics, hydrogels, epidermal systems, or sealed chambers [17], [18], [19], [20], [21]—enable continuous, real-time monitoring via impedance, optical, or water vapor sensing [22], e ff ectively minimizing evaporation during…”
Sulthana, S. F., Iqbal, U. M., Sreeja, B. S., & Anbazhagan, R. (2026) · Biosensors · doi:10.3390/bios16080410 · Cited by 1
Capillary Microfluidics for Bioanalysis: Design Principles and Application Perspectives
Baldo, T. A., Park, J., Bellows, R. A., & Henry, C. S. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00463 · Cited by 2
Romanholo, P. V. V., Silva‐Neto, H. A., Sgobbi, L. F., & Coltro, W. K. T. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00006-9 · Cited by 1
Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring
Naser, M., Nasr, M., & Shehata, L. H. (2023) · International Journal of Progressive Sciences and Technologies · doi:10.52155/ijpsat.v39.1.5361 · Cited by 1
Sample preparation using microfluidic technologies for non-invasive tests
Oksuz, C., Tarim, E. A., Ozcan, H. A., Koc, S., & Tekin, H. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00038-2 · Cited by 1
Challenges and trends in paper-based optical sensors
Sharifi, H., & Golmohammadi, H. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13356-5.00002-1 · Cited by 1
Legner, C. M. (2020) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-20210114-80
Song, Y., Gao, W. F., & Zhang, H. (2021) · Wiley eBooks · doi:10.1002/9783527833474.ch1
Capillary Microfluidics for Monitoring Medication Adherence
Delamarche, E., Temiz, Y., Lovchik, R. D., Christiansen, M. G., & Schuerle, S. (2021) · Angewandte Chemie · doi:10.1002/ange.202101316
One-Step Nanoscale Patterning of Silver Ionic Ink via Elastic Mold Deformation
Oh, Y. S. (2023) · Journal of Sensor Science and Technology · doi:10.46670/jsst.2023.32.4.252
Sweat-based screening of biomarkers using an enzymatic bioelectrocatalytic approach
Michelraj, S., Mechoor, A., & Ganesh, V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-19039-1.00014-6
Nien, H., & Li, B. (2023) · Revista de Química · doi:10.18800/quimica.202302.003
Synthetic BREs and Smart Nanomaterial‐Based Biosensors
Kaur, B., Kumar, S., & Kaushik, B. K. (2024) · Wiley eBooks · doi:10.1002/9781394268238.ch8
Liu, T., Miao, Y., Song, Z., Sun, X., Luo, Y., Zhuang, C., Zhou, J., Liu, C., & Xue, N. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784944
Micro/millifluidic platforms for bioanalytical applications
Henry, C. S., Ataide, V. N., Cherwin, A. E., Baldo, T. A., Russo, M. J., Meloni, G. N., & Paixão, T. R. L. C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-15675-5.00017-3
Color Intelligent Analysis Based on Deep Learning
Yang, S., Tong, C., & Que, L. (2024) · International Conference on Internet of Things, Robotics and Distributed Computing (ICIRDC) · doi:10.1109/icirdc65564.2024.00066
“Choi J used colorimetric chemistry technology for analysis to collect integrated microfluidic systems for soft skin [3].”
Self-Powered Wearable Health Monitoring Platform
Eslami, R. (2025) · doi:10.32920/30320887
Gotsmy, M., Brunmair, J., Büschl, C., Gerner, C., & Zanghellini, J. (2022) · Figshare · doi:10.6084/m9.figshare.21151115
New Frontiers in Chemical and Biochemical Methods
Biddle, G. (2023) · ThinkTech (Texas Tech University)
Bakhshandeh, F. (2024) · MacSphere (McMaster University) · doi:10.71548/16734
Mussel protein-graphene hybrid sponge with lung-mimicking architecture for rapid glucose detection
Shi, H., Sun, N., Li, Q., Tan, D., Bi, S., Li, L., Yang, S., & Jiang, C. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.172503
Sweat detection based on wearable electrochemical sensors: status and prospects
Lin, X. (2025) · International Conference on Smart Healthcare and Wearable Intelligent Devices (SHWID) · doi:10.1145/3788112.3788118
“The flexible microfluidic colorimetric platform developed by Rogers’ team [30] can simultaneously monitor lactic acid, temperature, perspiration rate, chloride ions, and glucose.”
Hashimoto, Y., Noto, K., Tada, S., & NISHIDA, Y. (2026) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.146.128
Hashimoto, Y., Noto, K., Tada, S., & Nishida, Y. (2026) · Electrical Engineering in Japan · doi:10.1002/eej.70031
Hydrogel-Based Colorimetric Biosensors Enhanced by Artificial Intelligence for Wearable Diagnostics
Chenani, H., Razaghi, Z., Saeidi, M., & Simchi, A. (2026) · Springer eBooks · doi:10.1007/978-3-032-21981-7_1
Body‐integrated photonic biosensors: Illuminating the path to active healthcare
Gu, J., Wen, X., Yan, Q., ZHAO, Y., Yuan, L., Chen, S., Ma, Y., 方正月, Lei, D., Liu, Y., et al. (2026) · FlexMat. · doi:10.1002/flm2.70098 · Cited by 1
Wang, Y., Wen, Y., Wang, X., Sun, H., Feng, H., Ma, Z., Li, Y., Chen, M., Chen, D., Shi, Y., et al. (2026) · Advanced Materials · doi:10.1002/adma.73620
“In particular, sweat sensing has benefited from microfluidic routing [26], colorimetric assays [27], and electrochemical detection [28, 29], which substantially improve sweat collection and analysis.”
Zhou, M., Yang, D. S., Kim, J., Kim, J.-H., Kanatzidis, E. E., Kim, J. U., Oh, S., Rugg, L., Mathur, R., Li, S., et al. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-03056-9
Self-citationLan, W., Qiu, Y., Ye, Y., Chen, Y., Chen, X., Wang, W., & Tang, Y. (2026) · ACS Sensors · doi:10.1021/acssensors.6c01873
Water-Developable Ionic Liquid Polymer Enables Humidity-Sensing and Microscale Patterning
Mimura, T., Warlick, L., Zele, A., Landfield, H., Kuehster, L., Lynd, N. A., & Segalman, R. A. (2026) · ACS Macro Letters · doi:10.1021/acsmacrolett.6c00360
Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions
Alam, A., Gull, F., Hameed, M., Iqbal, I., Naz, S., Noor, H., Aslam, A., Younis, S., Vit, V., Mehmood, M. A., et al. (2026) · Electrochemical Science Advances · doi:10.1002/elsa.70041
Ye, Z., Chen, Y., He, Q., Xiang, W., Lu, Y., Xiao, L., Chen, J., & You, R. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182218
Electrospun nanofibers based sensors in the context of health monitoring
Verpoorten, E. (2022) · PORTO@Iris
Zhang, Y., Bain, I., Huang, Y., Ecevitoglu, A., Dong, F., Chen, J., Edelstein, G. A., Zhang, X., Li, H., Weng, Z., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2533689123
Guo, S., Wang, H., & Bo, X. (2026) · The Analyst · doi:10.1039/d6an01127f
Kılıç, M. S., & Korkut, S. (2026) · The Chemical Record · doi:10.1002/tcr.70268
Raja, P. U. M., Sasikumar, G. K., Abirami, K., Shenthilkumar, R. R., Pothu, R., & Boddula, R. (2026) · Measurement · doi:10.1016/j.measurement.2026.123758
Metadata
- Authors
- Choi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., Xu, S., Ghaffari, R., & Rogers, J. A.
- Affiliations
- Northwestern University (US)
- University of Illinois Urbana-Champaign (US)
- Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois 60208, United States
- Corresponding author
- Rogers, John A.
- ORCID
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-01
- Volume
- 4
- Issue
- 2
- Pages
- 379-388
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2913004087
- Cited by
- 365
- References
- 48
- Citations by year
- 2026: 29 · 2025: 44 · 2024: 59 · 2023: 64 · 2022: 60 · 2021: 54 · 2020: 36 · 2019: 19
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Sensors (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Center for Bio-Integrated Electronics, Northwestern University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- sweat analysis, sweat biomarkers, colorimetric sensing, sweat rate, sweat loss, sweat pH, chloride, glucose, lactate, wearable sensors, sweat collection, digital image analysis
- MeSH terms
- Colorimetry, Humans, Skin, Sweat, Temperature, Biomarkers, Mechanical Phenomena, Lab-On-A-Chip Devices, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.