The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Laser-Induced Graphene Electrochemical Immunosensors for Rapid and Label-Free Monitoring of Salmonella enterica in Chicken Broth
Abstract
Food-borne illnesses are a growing concern for the food industry and consumers, with millions of cases reported every year. Consequently, there is a critical need to develop rapid, sensitive, and inexpensive techniques for pathogen detection in order to mitigate this problem. However, current pathogen detection strategies mainly include time-consuming laboratory methods and highly trained personnel. Electrochemical in-field biosensors offer a rapid, low-cost alternative to laboratory techniques, but the electrodes used in these biosensors require expensive nanomaterials to increase their sensitivity, such as noble metals (e.g., platinum, gold) or carbon nanomaterials (e.g., carbon nanotubes, or graphene). Herein, we report the fabrication of a highly sensitive and label-free laser-induced graphene (LIG) electrode that is subsequently functionalized with antibodies to electrochemically quantify the food-borne pathogen Salmonella enterica serovar Typhimurium. The LIG electrodes were produced by laser induction on the polyimide film in ambient conditions and, hence, circumvent the need for high-temperature, vacuum environment, and metal seed catalysts commonly associated with graphene-based electrodes fabricated via chemical vapor deposition processes. After functionalization with Salmonella antibodies, the LIG biosensors were able to detect live Salmonella in chicken broth across a wide linear range (25 to 10 5 CFU mL –1 ) and with a low detection limit (13 ± 7 CFU mL –1; n = 3, mean ± standard deviation). These results were acquired with an average response time of 22 min without the need for sample preconcentration or redox labeling techniques. Moreover, these LIG immunosensors displayed high selectivity as demonstrated by nonsignificant response to other bacteria strains. These results demonstrate how LIG-based electrodes can be used for electrochemical immunosensing in general and, more specifically, could be used as a viable option for rapid and low-cost pathogen detection in food processing facilities before contaminated foods reach the consumer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric Field Effect in Atomically Thin Carbon Films
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Zhang, Y., Dubonos, S. V., Grigorieva, I. V., & Firsov, A. A. (2004) · Science · doi:10.1126/science.1102896 · Cited by 66,834
Thermal properties of graphene and nanostructured carbon materials
Balandin, A. A. (2011) · Nature Materials · doi:10.1038/nmat3064 · Cited by 6,244
Studying disorder in graphite-based systems by Raman spectroscopy
Pimenta, M. A., Dresselhaus, G., Dresselhaus, M. S., Cançado, L. G., Jorio, A., & Saito, R. (2007) · Phys. Chem. Chem. Phys. · doi:10.1039/b613962k · Cited by 4,623
Laser Scribing of High-Performance and Flexible Graphene-Based Electrochemical Capacitors
El-Kady, M. F., Strong, V., Dubin, S., & Kaner, R. B. (2012) · Science · doi:10.1126/science.1216744 · Cited by 4,008
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Theory and Application of Cyclic Voltammetry for Measurement of Electrode Reaction Kinetics.
Nicholson, R. S. (1965) · Analytical Chemistry · doi:10.1021/ac60230a016 · Cited by 3,446
Synthesis of N-Doped Graphene by Chemical Vapor Deposition and Its Electrical Properties
Wei, D., Liu, Y., Wang, Y., Zhang, H., Huang, L., & Yu, G. (2009) · Nano Letters · doi:10.1021/nl803279t · Cited by 3,074
Laser-induced porous graphene films from commercial polymers
Lin, J., Peng, Z., Liu, Y., Ruiz-Zepeda, F., Ye, R., Samuel, E. L. G., Yacaman, M. J., Yakobson, B. I., & Tour, J. M. (2014) · Nature Communications · doi:10.1038/ncomms6714 · Cited by 2,946
Pathogen detection: A perspective of traditional methods and biosensors
Lazcka, O., Campo, F. J. D., & Muñoz, F. X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.036 · Cited by 1,500
Law, J. W.-F., Ab Mutalib, N.-S., Chan, K.-G., & Lee, L.-H. (2015) · Frontiers in Microbiology · doi:10.3389/fmicb.2014.00770 · Cited by 1,205
Inkjet-Printed Graphene Electronics
Torrisi, F., Hasan, T., Wu, W., Sun, Z., Lombardo, A., Kulmala, T. S., Hsieh, G.-W., Jung, S., Bonaccorso, F., Paul, P. J., et al. (2012) · ACS Nano · doi:10.1021/nn2044609 · Cited by 1,195
Pumera, M. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70160-2 · Cited by 851
Ye, R., James, D. K., & Tour, J. M. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00084 · Cited by 795
Inkjet Printing of High Conductivity, Flexible Graphene Patterns
Secor, E. B., Prabhumirashi, P. L., Puntambekar, K., Geier, M. L., & Hersam, M. C. (2013) · The Journal of Physical Chemistry Letters · doi:10.1021/jz400644c · Cited by 693
High‐Performance Pseudocapacitive Microsupercapacitors from Laser‐Induced Graphene
Li, L., Zhang, J., Peng, Z., Li, Y., Gao, C., Ji, Y., Ye, R., Kim, N. D., Zhong, Q., Yang, Y., et al. (2016) · Advanced Materials · doi:10.1002/adma.201503333 · Cited by 571
An intelligent artificial throat with sound-sensing ability based on laser induced graphene
Tao, L.-Q., Tian, H., Liu, Y., Ju, Z.-Y., Pang, Y., Chen, Y.-Q., Wang, D.-Y., Tian, X.-G., Yan, J.-C., Deng, N.-Q., et al. (2017) · Nature Communications · doi:10.1038/ncomms14579 · Cited by 558
Wang, Q. H., Jin, Z., Kim, K. K., Hilmer, A. J., Paulus, G. L. C., Shih, C.-J., Ham, M.-H., Sanchez-Yamagishi, J. D., Watanabe, K., Taniguchi, T., et al. (2012) · Nature Chemistry · doi:10.1038/nchem.1421 · Cited by 540
Highly Stretchable and Sensitive Unidirectional Strain Sensor via Laser Carbonization
Rahimi, R., Ochoa, M., Yu, W., & Ziaie, B. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am509087u · Cited by 400
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
Abellán-Llobregat, A., Jeerapan, I., Bandodkar, A., Vidal, L., Canals, A., Wang, J., & Morallón, E. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.058 · Cited by 348
Electrochemical biosensors for fast detection of food contaminants – trends and perspective
Rotariu, L., Lagarde, F., Jaffrezic-Renault, N. J., & Bala, C. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.12.017 · Cited by 324
Tuneable electronic properties in graphene
Craciun, M. F., Russo, S., Yamamoto, M., & Tarucha, S. (2011) · Nano Today · doi:10.1016/j.nantod.2010.12.001 · Cited by 320
Highly Efficient Laser Scribed Graphene Electrodes for On‐Chip Electrochemical Sensing Applications
Nayak, P., Kurra, N., Xia, C., & Alshareef, H. N. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201600185 · Cited by 293
Ye, J., Tan, H., Wu, S., Ni, K., Pan, F., Liu, J., Tao, Z., Qu, Y., Ji, H., Simon, P., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801384 · Cited by 241
Sheikhzadeh, E., Chamsaz, M., Turner, A. P. F., Jager, E. W. H., & Beni, V. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.057 · Cited by 236
Abbas, A. N., Liu, G., Liu, B., Zhang, L., Liu, H., Ohlberg, D., Wu, W., & Zhou, C. (2014) · ACS Nano · doi:10.1021/nn405759v · Cited by 234
Laser-Scribed Graphene Electrodes for Aptamer-Based Biosensing
Fenzl, C., Nayak, P., Hirsch, T., Wolfbeis, O. S., Alshareef, H. N., & Baeumner, A. J. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00066 · Cited by 210
Progress in utilisation of graphene for electrochemical biosensors
Lawal, A. T. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.030 · Cited by 210
Molecularly-imprinted chloramphenicol sensor with laser-induced graphene electrodes
Cardoso, A. R., Marques, A. C., Santos, L., Carvalho, A. F., Costa, F. M., Martins, R., Sales, M. G. F., & Fortunato, E. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.015 · Cited by 205
Flexible Laser-Induced Graphene for Nitrogen Sensing in Soil
Garland, N. T., McLamore, E. S., Cavallaro, N. D., Mendivelso-Perez, D., Smith, E. A., Jing, D., & Claussen, J. C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b10991 · Cited by 200
Self-citationLaser-derived graphene: A three-dimensional printed graphene electrode and its emerging applications
Kurra, N., Jiang, Q., Nayak, P., & Alshareef, H. N. (2019) · Nano Today · doi:10.1016/j.nantod.2018.12.003 · Cited by 198
Recent advances in aptasensors based on graphene and graphene-like nanomaterials
Ping, J., Zhou, Y., Wu, Y., Papper, V., Boujday, S., Marks, R. S., & Steele, T. W. J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.090 · Cited by 187
Ohk, S. H., Koo, O. K., Sen, T., Yamamoto, C. M., & Bhunia, A. K. (2010) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2010.04709.x · Cited by 182
UV Laser‐Induced Polyimide‐to‐Graphene Conversion: Modeling, Fabrication, and Application
Chen, Y., Long, J., Zhou, S., Shi, D., Huang, Y., Chen, X., Gao, J., Zhao, N., & Wong, C. (2019) · Small Methods · doi:10.1002/smtd.201900208 · Cited by 174
Electrochemical biosensors for Salmonella: State of the art and challenges in food safety assessment
Silva, N. F. D., Magalhães, J. M. C. S., Freire, C., & Delerue-Matos, C. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.019 · Cited by 173
Laser-induced graphene: preparation, functionalization and applications
Wang, F., Wang, K., Zheng, B., Dong, X., Mei, X., Lv, J., Duan, W., & Wang, W. (2018) · Materials Technology · doi:10.1080/10667857.2018.1447265 · Cited by 160
Tehrani, F., & Bavarian, B. B. (2016) · Scientific Reports · doi:10.1038/srep27975 · Cited by 154
Detection of Salmonella typhimurium using an electrochemical immunosensor
Salam, F., & Tothill, I. E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.01.025 · Cited by 153
Electrical Property of Graphene and Its Application to Electrochemical Biosensing
Lee, J., Park, S.-J., & Choi, J. (2019) · Nanomaterials · doi:10.3390/nano9020297 · Cited by 153
Economic Burden of Major Foodborne Illnesses Acquired in the United StatesPreprint
Hoffman, S., Maculloch, B., & Batz, M. (2015) · RePEc: Research Papers in Economics · doi:10.22004/ag.econ.205081 · Cited by 148
Aerosol-Jet-Printed Graphene Immunosensor for Label-Free Cytokine Monitoring in Serum
Parate, K., Rangnekar, S. V., Jing, D., Mendivelso-Perez, D. L., Ding, S., Secor, E. B., Smith, E. A., Hostetter, J. M., Hersam, M. C., & Claussen, J. C. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22183 · Cited by 142
Self-citationDas, S. R., Nian, Q., Cargill, A. A., Hondred, J. A., Ding, S., Saei, M., Cheng, G. J., & Claussen, J. C. (2016) · Nanoscale · doi:10.1039/c6nr04310k · Cited by 128
Self-citationAppaturi, J. N., Pulingam, T., Thong, K. L., Muniandy, S., Ahmad, N., & Leo, B. F. (2019) · Analytical Biochemistry · doi:10.1016/j.ab.2019.113489 · Cited by 125
Vanegas, D. C., Patiño, L., Mendez, C., de Oliveira, D. A., Torres, A. M., Gomes, C. L., & McLamore, E. S. (2018) · Biosensors · doi:10.3390/bios8020042 · Cited by 123
Self-citationGriffiths, K., Dale, C., Hedley, J., Kowal, M. D., Kaner, R. B., & Keegan, N. (2014) · Nanoscale · doi:10.1039/c4nr04221b · Cited by 120
Muniandy, S., Teh, S. J., Appaturi, J. N., Thong, K. L., Lai, C. W., Ibrahim, F., & Leo, B. F. (2019) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2019.02.005 · Cited by 115
A microfluidic based biosensor for rapid detection of Salmonella in food products
Liu, J., Jasim, I. H., Shen, Z., Zhao, L., Dweik, M., Zhang, S., & Almasri, M. F. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216873 · Cited by 102
Ding, S., Mosher, C., Lee, X. Y., Das, S. R., Cargill, A. A., Tang, X., Chen, B., McLamore, E. S., Gomes, C. L., Hostetter, J. M., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00581 · Cited by 101
Self-citationEmerging Biorecognition and Transduction Schemes for Rapid Detection of Pathogenic Bacteria in Food
Vanegas, D. C., Gomes, C. L., Cavallaro, N. D., Giraldo‐Escobar, D., & McLamore, E. S. (2017) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12294 · Cited by 94
Self-citationMonolithic and Flexible ZnS/SnO 2 Ultraviolet Photodetectors with Lateral Graphene Electrodes
Zhang, C., Xie, Y., Deng, H., Tumlin, T. M., Zhang, C., Su, J., Yu, P., & Lin, J. (2017) · Small · doi:10.1002/smll.201604197 · Cited by 88
Zhang, W., Lei, Y., Jiang, Q. M., Ming, F., Costa, P. M. F. J., & Alshareef, H. N. (2019) · Small Methods · doi:10.1002/smtd.201900005 · Cited by 87
Mutreja, R., Jariyal, M., Pathania, P., Sharma, A., Sahoo, D. K., & Suri, C. R. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.05.079 · Cited by 82
Graphene-based biosensors for on-site detection of contaminants in food
Bobrinetskiy, I. I., & Knežević, N. Ž. (2018) · Analytical Methods · doi:10.1039/c8ay01913d · Cited by 82
Cho, I., & Ku, S. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18102078 · Cited by 79
Ye, Y., Yan, W., Liu, Y., He, S., Cao, X., Xu, X., Zheng, H., & Gunasekaran, S. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.05.012 · Cited by 76
A Rapid and Specific Biosensor for Salmonella Typhimurium Detection in Milk
Alexandre, D. L., Melo, A. M. A., Furtado, R. F., Borges, M. D. F., de Figueiredo, E. A. T., Biswas, A., CHENG, H. N., & Alves, C. R. (2018) · Food and Bioprocess Technology · doi:10.1007/s11947-017-2051-8 · Cited by 69
Meniscus-Mask Lithography for Narrow Graphene Nanoribbons
Abramova, V. V., Slesarev, A. S., & Tour, J. M. (2013) · ACS Nano · doi:10.1021/nn403057t · Cited by 63
Hondred, J. A., Medintz, I. L., & Claussen, J. C. (2019) · Nanoscale Horizons · doi:10.1039/c8nh00377g · Cited by 55
Self-citationActuation of chitosan-aptamer nanobrush borders for pathogen sensing
Hills, K. D., de Oliveira, D. A., Cavallaro, N. D., Gomes, C. L., & McLamore, E. S. (2018) · The Analyst · doi:10.1039/c7an02039b · Cited by 50
Self-citationThe Effect of Sterilization Methods on Plastics and Elastomers
(2018) · Elsevier eBooks · doi:10.1016/c2017-0-01592-6 · Cited by 47
Clais, S., Boulet, G., Kerckhoven, M. V., Lanckacker, E. A., Delputte, P., Maes, L. J. R. M., & Cos, P. (2014) · Letters in Applied Microbiology · doi:10.1111/lam.12341 · Cited by 44
Cited by
Le, T. D., Phan, H., Kwon, S., Park, S., Jung, Y., Min, J., Chun, B. J., Yoon, H., Ko, S. H., Kim, S., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202205158 · Cited by 433
Vivaldi, F. M., Dallinger, A., Bonini, A., Poma, N., Sembranti, L., Biagini, D., Salvo, P., Greco, F., & Di Francesco, F. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c05614 · Cited by 364
Metadata
- Authors
- Soares, R. R. A., Hjort, R. G., Pola, C. C., Parate, K., Reis, E. L., Soares, N. F. F., McLamore, E. S., Claussen, J. C., & Gomes, C. L.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-04-29
- Volume
- 5
- Issue
- 7
- Pages
- 1900-1911
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W3019042088
- Cited by
- 259
- References
- 61
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.