The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Lipid-Shelled Vehicles: Engineering for Ultrasound Molecular Imaging and Drug Delivery
Open accessAbstract
Ultrasound pressure waves can map the location of lipid-stabilized gas micro-bubbles after their intravenous administration in the body, facilitating an estimate of vascular density and microvascular flow rate. Microbubbles are currently approved by the Food and Drug Administration as ultrasound contrast agents for visualizing opacification of the left ventricle in echocardiography. However, the interaction of ultrasound waves with intravenously-injected lipid-shelled particles, including both liposomes and microbubbles, is a far richer field. Particles can be designed for molecular imaging and loaded with drugs or genes; the mechanical and thermal properties of ultrasound can then effect localized drug release. In this Account, we provide an overview of the engineering of lipid-shelled microbubbles (typical diameter 1000-10 000 nm) and liposomes (typical diameter 65-120 nm) for ultrasound-based applications in molecular imaging and drug delivery. The chemistries of the shell and core can be optimized to enhance stability, circulation persistence, drug loading and release, targeting to and fusion with the cell membrane, and therapeutic biological effects. To assess the biodistribution and pharmacokinetics of these particles, we incorporated positron emission tomography (PET) radioisotopes on the shell. The radionuclide (18)F (half-life approximately 2 h) was covalently coupled to a dipalmitoyl lipid, followed by integration of the labeled lipid into the shell, facilitating short-term analysis of particle pharmacokinetics and metabolism of the lipid molecule. Alternately, labeling a formed particle with (64)Cu (half-life 12.7 h), after prior covalent incorporation of a copper-chelating moiety onto the lipid shell, permits pharmacokinetic study of particles over several days. Stability and persistence in circulation of both liposomes and microbubbles are enhanced by long acyl chains and a poly(ethylene glycol) coating. Vascular targeting has been demonstrated with both nano- and microdiameter particles. Targeting affinity of the microbubble can be modulated by burying the ligand within a polymer brush layer; the application of ultrasound then reveals the ligand, enabling specific targeting of only the insonified region. Microbubbles and liposomes require different strategies for both drug loading and release. Microbubble loading is inhibited by the gas core and enhanced by layer-by-layer construction or conjugation of drug-entrapped particles to the surface. Liposome loading is typically internal and is enhanced by drug-specific loading techniques. Drug release from a microbubble results from the oscillation of the gas core diameter produced by the sound wave, whereas that from a liposome is enhanced by heat produced from the local absorption of acoustic energy within the tissue microenvironment. Biological effects induced by ultrasound, such as changes in cell membrane and vascular permeability, can enhance drug delivery. In particular, as microbubbles oscillate near a vessel wall, shock waves or liquid jets enhance drug transport. Mild heating induced by ultrasound, either before or after injection of the drug, facilitates the transport of liposomes from blood vessels to the tissue interstitium, thus increasing drug accumulation in the target region. Lipid-shelled vehicles offer many opportunities for chemists and engineers; ultrasound-based applications beyond the few currently in common use will undoubtedly soon multiply as molecular construction techniques are further refined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of Liposomes for Enhanced Local Release of Drugs by Hyperthermia
Yatvin, M. B., Weinstein, J. N., Dennis, W. H., & Blumenthal, R. (1978) · Science · doi:10.1126/science.364652 · Cited by 956
Targeted pharmaceutical nanocarriers for cancer therapy and imaging
Torchilin, V. P. (2007) · The AAPS Journal · doi:10.1208/aapsj0902015 · Cited by 762
Needham, D., Anyarambhatla, G., Kong, G., & Dewhirst, M. W. (2000) · PubMed · Cited by 746
Structures of complement component C3 provide insights into the function and evolution of immunity
Janssen, B. J. C., Huizinga, E. G., Raaijmakers, H. C. A., Roos, A., Daha, M. R., Nilsson-Ekdahl, K., Nilsson, B., & Gros, P. (2005) · Nature · doi:10.1038/nature04005 · Cited by 541
Dromi, S., Frenkel, V., Luk, A., Traughber, B., Angstadt, M., Bur, M., Poff, J., Xie, J., Libutti, S. K., Li, K. C. P., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-2443 · Cited by 492
Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Qin, S., Caskey, C. F., & Ferrara, K. W. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/r01 · Cited by 453
Self-citationLigand-targeted liposomal anticancer drugs
Sapra, P., & Allen, T. M. (2003) · Progress in Lipid Research · doi:10.1016/s0163-7827(03)00032-8 · Cited by 438
Grafted poly(ethylene oxide) brushes as nonfouling surface coatings
Leckband, D., Sheth, S., & Halperin, A. (1999) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856299x00720 · Cited by 324
Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V. (2003) · Circulation · doi:10.1161/01.cir.0000084535.35435.ae · Cited by 321
Influence of lipid shell physicochemical properties on ultrasound-induced microbubble destruction
Borden, M. A., Kruse, D. E., Caskey, C. F., Zhao, S., Dayton, P. A., & Ferrara, K. W. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1561668 · Cited by 293
Self-citationPharmacokinetics and in vivo drug release rates in liposomal nanocarrier development
Drummond, D. C., Noble, C. O., Hayes, M. E., Park, J. W., & Kirpotin, D. B. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21358 · Cited by 289
Ultrasound radiation force enables targeted deposition of model drug carriers loaded on microbubbles
Lum, A. F. H., Borden, M. A., Dayton, P. A., Kruse, D. E., Simon, S. I., & Ferrara, K. W. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.11.006 · Cited by 262
Self-citationHaidar, Z. S., Hamdy, R. C., & Tabrizian, M. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.012 · Cited by 260
Duncan, P. B., & Needham, D. (2004) · Langmuir · doi:10.1021/la034930i · Cited by 250
Kheirolomoom, A., Dayton, P. A., Lum, A. F. H., Little, E., Paoli, E. E., Zheng, H., & Ferrara, K. W. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.12.015 · Cited by 225
Self-citationStieger, S. M., Caskey, C. F., Adamson, R. H., Qin, S., Curry, F.-R. E., Wisner, E. R., & Ferrara, K. W. (2007) · Radiology · doi:10.1148/radiol.2431060167 · Cited by 158
Self-citationOptical observation of contrast agent destruction
Chomas, J. E., Dayton, P. A., May, D. J., Allen, J. S., Klibanov, A. L., & Ferrara, K. W. (2000) · Applied Physics Letters · doi:10.1063/1.1287519 · Cited by 157
Self-citationInterfacial Polygonal Nanopatterning of Stable Microbubbles
Dressaire, E., Bee, R. D., Bell, D. C., et al. (2008) · Science · doi:10.1126/science.1154601 · Cited by 151
Therapeutic effects of paclitaxel-containing ultrasound contrast agents
Tartis, M., McCallan, J. L., Lum, A. F. H., LaBell, R., Stieger‐Vanegas, S. M., Matsunaga, T. O., & Ferrara, K. W. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.03.017 · Cited by 148
Self-citationLateral Phase Separation in Lipid-Coated Microbubbles
Borden, M. A., Martinez, G. V., Ricker, J. V., Tsvetkova, N. M., Longo, M. L., Gillies, R. J., Dayton, P. A., & Ferrara, K. W. (2006) · Langmuir · doi:10.1021/la052841v · Cited by 142
Self-citationSurface phase behavior and microstructure of lipid/PEG-emulsifier monolayer-coated microbubbles
Borden, M. A., Pu, G., Runner, G. J., et al. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.03.007 · Cited by 141
Self-citationMyocardial Contrast Echocardiography
Kaul, S. (2008) · Circulation · doi:10.1161/circulationaha.107.747303 · Cited by 138
DNA and Polylysine Adsorption and Multilayer Construction onto Cationic Lipid-Coated Microbubbles
Borden, M. A., Caskey, C. F., Little, E. L., Gillies, R. J., & Ferrara, K. W. (2007) · Langmuir · doi:10.1021/la7009034 · Cited by 137
Self-citationA Novel Method to Label Preformed Liposomes with 64Cu for Positron Emission Tomography (PET) Imaging
Seo, J. W., Zhang, H., Kukis, D. L., Meares, C. F., & Ferrara, K. W. (2008) · Bioconjugate Chemistry · doi:10.1021/bc8002937 · Cited by 121
Self-citationLateral phase separation in interfacial films of pulmonary surfactant
Discher, B. M., Maloney, K. M., Schief, W. R., Grainger, D. W., Viola Vogel, B., & Hall, S. B. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79450-x · Cited by 110
Long-circulating liposomes radiolabeled with [18F]fluorodipalmitin ([18F]FDP)
Mařík, J., Tartis, M., Zhang, H., Fung, J. Y., Kheirolomoom, A., Sutcliffe-Goulden, J., & Ferrara, K. W. (2007) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2006.12.004 · Cited by 110
Self-citationA stimulus-responsive contrast agent for ultrasound molecular imaging
Borden, M. A., Zhang, H., Gillies, R. J., Dayton, P. A., & Ferrara, K. W. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.10.011 · Cited by 106
Self-citationUltrasound-enhanced tissue plasminogen activator thrombolysis in an in vitro porcine clot model
Holland, C. K., Vaidya, S. S., Datta, S., Coussios, C. C., & Shaw, G. J. (2007) · Thrombosis Research · doi:10.1016/j.thromres.2007.07.006 · Cited by 103
Imaging of angiogenesis using Cadence™ contrast pulse sequencing and targeted contrast agents
Stieger‐Vanegas, S. M., Dayton, P. A., Borden, M. A., et al. (2008) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.224 · Cited by 87
Self-citationDynamic microPET imaging of ultrasound contrast agents and lipid delivery
Tartis, M., Kruse, D. E., Zheng, H., Zhang, H., Kheirolomoom, A., Mařík, J., & Ferrara, K. W. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.07.030 · Cited by 87
Self-citationDynamic imaging of arginine-rich heart-targeted vehicles in a mouse model
Zhang, H., Kusunose, J., Kheirolomoom, A., et al. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.033 · Cited by 44
Self-citation
Cited by
Imaging and drug delivery using theranostic nanoparticles
Janib, S. M., Moses, A. S., & MacKay, J. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.08.004 · Cited by 1,248
Acoustic behavior of microbubbles and implications for drug delivery
Kooiman, K., Vos, H. J., Versluis, M., & de Jong, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.003 · Cited by 401
Ultrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery
Kooiman, K., Roovers, S., Langeveld, S. A. G., Kleven, R. T., Dewitte, H., O'Reilly, M. A., Escoffre, J.-M., Bouakaz, A., Verweij, M. D., Hynynen, K., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.01.002 · Cited by 359
Cavitation properties of block copolymer stabilized phase-shift nanoemulsions used as drug carriers
Rapoport, N., Christensen, D. A., Kennedy, A. M., & Nam, K.-H. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.11.009 · Cited by 79
Metadata
- Authors
- Ferrara, K. W., Borden, M. A., & Zhang, H.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-25
- Volume
- 42
- Issue
- 7
- Pages
- 881-892
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2030902462
- Cited by
- 332
- References
- 31
- FWCI
- 15.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.