The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
pH Effects on Iron-Catalyzed Oxidation using Fenton’s Reagent
Open accessAbstract
This work extends investigations into the development and use of a kinetic model to simulate and improve the iron-catalyzed oxidation of organic compounds using Fenton's reagent. While a number of recent studies have successfully modeled the kinetics and species behavior in simple Fenton systems, none have extended and applied the model to examine the effect of operating parameters such as pH on treatment performance. The purpose of this work is to investigate the effect of pH in Fenton-based oxidation systems and to use kinetic modeling to gain insight into the reaction mechanism and speciation of the iron catalyst. Laboratory experiments were conducted across a range of starting concentrations of Fe(II) and H2O2 at pHs of 2.5, 3.0, and 4.0, both in the presence and absence of a target organic, formic acid (HCOOH). With minor modifications, the model presented is capable of accurately describing changes in Fe(II) concentrations over a wide range of reaction conditions and, provided account is taken of additional hydroxyl radical scavenging pathways, also accounts for the oxidation of formic acid over extended reaction times at all pHs considered. The use of composite values for rate constants of reactions involving weakly acidic species is shown to be appropriate, and analysis of the model reveals the catalytic role iron plays in the oxidation process. Experimental and simulated data at the different pHs highlights the effect the catalytic redox cycling of iron has on the performance and oxidation capacity of the Fenton system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Pignatello, J. J., Oliveros, E., & MacKay, A. (2006) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380500326564 · Cited by 4,133
LXXIII.—Oxidation of tartaric acid in presence of iron
Fenton, H. J. H. (1894) · J. Chem. Soc., Trans. · doi:10.1039/ct8946500899 · Cited by 3,179
Walling, C. (1975) · Accounts of Chemical Research · doi:10.1021/ar50088a003 · Cited by 2,850
A review of classic Fenton’s peroxidation as an advanced oxidation technique
Neyens, E., & Baeyens, J. (2003) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(02)00282-0 · Cited by 2,438
Reactivity of HO2/O− 2 radicals in aqueous solution
Bielski, B. H. J., Cabelli, D. E., Arudi, R. L., & Ross, A. B. (1985) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555739 · Cited by 2,169
Oxidation of tartaric acid in presence of iron
Fenton, H. J. H. (1894) · Journal of the Chemical Society (Resumed) · Cited by 1,498
Bader, H., Sturzenegger, V., & Hoigné, J. (1988) · Water Research · doi:10.1016/0043-1354(88)90005-x · Cited by 940
Hug, S. J., & Leupin, O. (2003) · Environmental Science & Technology · doi:10.1021/es026208x · Cited by 828
De Laat, J., & Gallard, H. (1999) · Environmental Science & Technology · doi:10.1021/es981171v · Cited by 749
Chen, R., & Pignatello, J. J. (1997) · Environmental Science & Technology · doi:10.1021/es9610646 · Cited by 676
Reactions of ferrous and ferric ions with hydrogen peroxide. Part I.—The ferrous ion reaction
Barb, W. G., Baxendale, J. H., George, P., & Hargrave, K. R. (1951) · Trans. Faraday Soc. · doi:10.1039/tf9514700462 · Cited by 539
Kwan, W. P., & Voelker, B. M. (2002) · Environmental Science & Technology · doi:10.1021/es011109p · Cited by 370
Effects of Fulvic Acid on Fe(II) Oxidation by Hydrogen Peroxide
Voelker, B. M., & Sulzberger, B. (1996) · Environmental Science & Technology · doi:10.1021/es9502132 · Cited by 363
Kinetic modeling of Fenton oxidation of phenol and monochlorophenols
Kang, N., Lee, D. S., & Yoon, J. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00067-x · Cited by 338
Gallard, H. (2000) · Water Research · doi:10.1016/s0043-1354(00)00074-9 · Cited by 298
Sun, Y., & Pignatello, J. J. (1992) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf00014a031 · Cited by 287
Mechanism of the Fenton reaction. Evidence for a new intermediate
Kremer, M. L. (1999) · Physical Chemistry Chemical Physics · doi:10.1039/a903915e · Cited by 255
Sychev, A. Y., & Isak, V. G. (1995) · Russian Chemical Reviews · doi:10.1070/rc1995v064n12abeh000195 · Cited by 198
Process Optimization of Fenton Oxidation Using Kinetic Modeling
Duesterberg, C. K., & Waite, T. D. (2006) · Environmental Science & Technology · doi:10.1021/es060311v · Cited by 179
Self-citationGallard, H., Laat, J. D., & Legube, B. (1998) · New Journal of Chemistry · doi:10.1039/a708335a · Cited by 144
Fenton-Mediated Oxidation in the Presence and Absence of Oxygen
Duesterberg, C. K., Cooper, W. J., & Waite, T. D. (2005) · Environmental Science & Technology · doi:10.1021/es048378a · Cited by 142
Self-citationBuxton, G. V., & Sellers, R. M. (1973) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19736900555 · Cited by 117
Flyunt, R., Schuchmann, M. N., & von Sonntag, C. (2001) · Chemistry - A European Journal · Cited by 97
Wells, C. F., & Salam, M. A. (1968) · Journal of the Chemical Society A Inorganic Physical Theoretical · doi:10.1039/j19680000024 · Cited by 53
Hydrolysis of Ferrous Ions : a Kinetic Method for the Determination of the Fe(II) Species
Wells, C. F., & SALAM, M. A. (1965) · Nature · doi:10.1038/205690b0 · Cited by 42
Kinetic Model for the Degradation of MTBE by Fenton’s Oxidation
Ananzeh, N. A., Bergendahl, J., & Thompson, R. W. (2006) · Environmental Chemistry · doi:10.1071/en05044 · Cited by 11
Cited by
Fe(II) Redox Chemistry in the Environment
Huang, J., Jones, A., Waite, T. D., Chen, Y., Huang, X., Rosso, K. M., Kappler, A., Mansor, M., Tratnyek, P. G., & Zhang, H. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01286 · Cited by 620
Self-citationReactive Oxygen Species‐Regulating Strategies Based on Nanomaterials for Disease Treatment
Zhang, C., Wang, X., Du, J., Gu, Z., & Zhao, Y. (2021) · Advanced Science · doi:10.1002/advs.202002797 · Cited by 401
Pang, S.-Y., Jiang, J., & Ma, J. (2011) · Environmental Science & Technology · doi:10.1021/es102401d · Cited by 329
Kurian, M., & Nair, D. S. (2015) · Journal of Water Process Engineering · doi:10.1016/j.jwpe.2014.10.011 · Cited by 112
Metadata
- Authors
- Duesterberg, C. K., Mylon, S. E., & Waite, T. D.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-10-22
- Volume
- 42
- Issue
- 22
- Pages
- 8522-8527
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2058215085
- Cited by
- 254
- References
- 27
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.