The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Single-Walled Carbon Nanotube Biosensors Using Aptamers as Molecular Recognition Elements
Abstract
We report the real-time detection of protein using SWNT-FET-based biosensors comprising DNA aptamers as molecular recognition elements. Anti-thrombin aptamers that are highly specific to serine protein thrombin were immobilized on the sidewall of a SWNT-FET using CDI-Tween linking molecules. The binding of thrombin aptamers to SWNT-FETs causes a rightward shift of the threshold gate voltages, presumably due to the negatively charged backbone of the DNA aptamers. While the addition of thrombin solution causes an abrupt decrease in the conductance of the thrombin aptamer immobilized SWNT-FET, no noticeable change was observed with elastase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Self-citationElectrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
Electronic Detection of Specific Protein Binding Using Nanotube FET Devices
Star, A., Gabriel, J.-C. P., Bradley, K., & Grüner, G. (2003) · Nano Letters · doi:10.1021/nl0340172 · Cited by 771
Aptamer-Functionalized Au Nanoparticles for the Amplified Optical Detection of Thrombin
Pavlov, V., Xiao, Y., Shlyahovsky, B., & Willner, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046970u · Cited by 692
Stable Ordering in Langmuir-Blodgett Films
Takamoto, D. Y., Aydil, E., Zasadzinski, J. A., Ivanova, A. T., Schwartz, D. K., Yang, T., & Cremer, P. S. (2001) · Science · doi:10.1126/science.1060018 · Cited by 208
Chemistry and biology of thrombin
Lundblad, R. L., Fenton, J. W., & Mann, K. G. (1977) · Medical Entomology and Zoology · Cited by 116
Cited by
Functional Nucleic Acid Sensors
Liu, J., Cao, Z., & Lu, Y. (2009) · Chemical Reviews · doi:10.1021/cr030183i · Cited by 2,187
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Current Progress on the Chemical Modification of Carbon Nanotubes
Karousis, N., Tagmatarchis, N., & Tasis, D. (2010) · Chemical Reviews · doi:10.1021/cr100018g · Cited by 1,317
Carbon nanomaterials for electronics, optoelectronics, photovoltaics, and sensing
Jariwala, D., Sangwan, V. K., Lauhon, L. J., Marks, T. J., & Hersam, M. C. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35335k · Cited by 1,284
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Cao, Q., & Rogers, J. A. (2009) · Advanced Materials · doi:10.1002/adma.200801995 · Cited by 1,098
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Carbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Chen, K.-I., Li, B.-R., & Chen, Y.-T. (2011) · Nano Today · doi:10.1016/j.nantod.2011.02.001 · Cited by 645
Aptamers as a replacement for antibodies in enzyme-linked immunosorbent assay
Toh, S. Y., Citartan, M., Gopinath, S. C. B., & Tang, T.-H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.026 · Cited by 612
Aptamers: molecular tools for analytical applications
Mairal, T., Cengiz Özalp, V., Lozano Sánchez, P., Mir, M., Katakis, I., & O’Sullivan, C. K. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1346-4 · Cited by 587
Carbon Nanotube-Quenched Fluorescent Oligonucleotides: Probes that Fluoresce upon Hybridization
Yang, R., Jin, J., Chen, Y., Shao, N., Kang, H., Xiao, Z., Tang, Z., Wu, Y., Zhu, Z., & Tan, W. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800604z · Cited by 551
Maiti, U. N., Lee, W. J., Lee, J. M., Oh, Y., Kim, J. Y., Kim, J. E., Shim, J., Han, T. H., & Kim, S. O. (2014) · Advanced Materials · doi:10.1002/adma.201303265 · Cited by 544
Self-citationCarbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules
Kim, S. N., Rusling, J. F., & Papadimitrakopoulos, F. (2007) · Advanced Materials · doi:10.1002/adma.200700665 · Cited by 502
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Seok Kim, Y., Ahmad Raston, N. H., & Bock Gu, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.040 · Cited by 442
Multiwall carbon nanotube scaffolds for tissue engineering purposes
Abarrategi, A., Gutiérrez, M. C., Moreno-Vicente, C., Hortigüela, M. J., Ramos, V., López-Lacomba, J. L., Ferrer, M. L., & del Monte, F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.09.021 · Cited by 435
Environmental application of nanotechnology: air, soil, and water
Ibrahim, R. K., Hayyan, M., AlSaadi, M. A., Hayyan, A., & Ibrahim, S. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-016-6457-z · Cited by 418
Nucleic acid aptamers and enzymes as sensors
Navani, N. K., & Li, Y. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.04.003 · Cited by 413
Biocompatible, Robust Free‐Standing Paper Composed of a TWEEN/Graphene Composite
Park, S., Mohanty, N., Suk, J. W., Nagaraja, A., An, J., Piner, R. D., Cai, W., Dreyer, D. R., Berry, V., & Ruoff, R. S. (2010) · Advanced Materials · doi:10.1002/adma.200903611 · Cited by 382
Nucleic Acid and Peptide Aptamers: Fundamentals and Bioanalytical Aspects
Mascini, M., Palchetti, I., & Tombelli, S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201006630 · Cited by 374
Surface immobilization methods for aptamer diagnostic applications
Balamurugan, S., Obubuafo, A., Soper, S. A., & Spivak, D. A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1587-2 · Cited by 312
Yang, R., Tang, Z., Yan, J., Kang, H., Kim, Y., Zhu, Z., & Tan, W. (2008) · Analytical Chemistry · doi:10.1021/ac801118p · Cited by 304
Self-citationAn Overview of Carbon Nanotubes and Graphene for Biosensing Applications
Zhu, Z. (2017) · Nano-Micro Letters · doi:10.1007/s40820-017-0128-6 · Cited by 303
Molecular diagnostic and drug delivery agents based on aptamer-nanomaterial conjugates
Lee, J. H., Yigit, M. V., Mazumdar, D., & Lu, Y. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.03.003 · Cited by 293
Self-citationRationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
So, H., Park, D., Jeon, E., Kim, Y., Kim, B. S., Lee, C., Choi, S. Y., Kim, S. C., Chang, H., & Lee, J. (2008) · Small · doi:10.1002/smll.200700664 · Cited by 288
Self-citationCarbon Nanotube (CNT)-Based Biosensors
Ferrier, D. C., & Honeychurch, K. C. (2021) · Biosensors · doi:10.3390/bios11120486 · Cited by 287
Byon, H. R., & Choi, H. C. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056897n · Cited by 278
Aptamers as molecular recognition elements for electrical nanobiosensors
Lee, J.-O., So, H.-M., Jeon, E.-K., Chang, H., Won, K., & Kim, Y. H. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1643-y · Cited by 277
Self-citationShen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Flexible FET-Type VEGF Aptasensor Based on Nitrogen-Doped Graphene Converted from Conducting Polymer
Kwon, O. S., Park, S. J., Hong, J.-Y., Han, A.-R., Lee, J. S., Lee, J. S., Oh, J. H., & Jang, J. (2012) · ACS Nano · doi:10.1021/nn204395n · Cited by 253
Self-citationKuang, Z., Kim, S. N., Crookes-Goodson, W. J., Farmer, B. L., & Naik, R. R. (2010) · ACS Nano · doi:10.1021/nn901365g · Cited by 184
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Metadata
- Authors
- So, H.-M., Won, K., Kim, Y. H., Kim, B.-K., Ryu, B. H., Na, P. S., Kim, H., & Lee, J.-O.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-01
- Volume
- 127
- Issue
- 34
- Pages
- 11906-11907
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2018648960
- Cited by
- 579
- References
- 7
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.