The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Detection of Homocysteine and Cysteine
Open accessAbstract
At elevated levels, homocysteine (Hcy, 1) is a risk factor for cardiovascular diseases, Alzheimer's disease, neural tube defects, and osteoporosis. Both 1 and cysteine (Cys, 3) are linked to neurotoxicity. The biochemical mechanisms by which 1 and 3 are involved in disease states are relatively unclear. Herein, we describe simple methods for detecting either Hcy or Cys in the visible spectral region with the highest selectivity reported to date without using biochemical techniques or preparative separations. Simple methods and readily available reagents allow for the detection of Cys and Hcy in the range of their physiologically relevant levels. New HPLC postcolumn detection methods for biological thiols are reported. The potential biomedical relevance of the chemical mechanisms involved in the detection of 1 is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Stadtman, E. R. (1993) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.62.070193.004053 · Cited by 1,395
Facts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode
Shahrokhian, S. (2001) · Analytical Chemistry · doi:10.1021/ac010541m · Cited by 1,033
Burdette, S. C., Walkup, G. K., Spingler, B., Tsien, R. Y., & Lippard, S. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010059l · Cited by 744
Homocysteine Levels and the Risk of Osteoporotic Fracture
van Meurs, J. B. J., Dhonukshe-Rutten, R. A. M., Pluijm, S. M. F., van der Klift, M., de Jonge, R., Lindemans, J., de Groot, L. C. P. G. M., Hofman, A., Witteman, J. C. M., van Leeuwen, J. P. T. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032546 · Cited by 740
Visual Detection of Cysteine and Homocysteine
Rusin, O., St. Luce, N. N., Agbaria, R. A., Escobedo, J. O., Jiang, S., Warner, I. M., Dawan, F. B., Lian, K., & Strongin, R. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja036297t · Cited by 516
Self-citationHomocysteine and other thiols in plasma and urine: automated determination and sample stability
Fiskerstrand, T., Refsum, H., Kvalheim, G., & Ueland, P. M. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.2.263 · Cited by 469
BIOCHEMISTRY OF SULFUR-CONTAINING AMINO ACIDS
Cooper, A. J. L. (1983) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.52.070183.001155 · Cited by 409
Rapid, fully automated measurement of plasma homocyst(e)ine with the Abbott IMx analyzer
Shipchandler, M. T., & Moore, E. G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.7.991 · Cited by 379
Studies on the Mechanism of Oxime and Semicarbazone Formation1
Jencks, W. P. (1959) · Journal of the American Chemical Society · doi:10.1021/ja01511a053 · Cited by 346
Ros-Lis, J. V., García, B., Jiménez, D., Martínez-Máñez, R., Sancenón, F., Soto, J., Gonzalvo, F., & Valldecabres, M. C. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031987i · Cited by 329
Analytical determination of homocysteine: a review
Nekrassova, O. (2003) · Talanta · doi:10.1016/s0039-9140(03)00173-5 · Cited by 310
Studies on the Mechanism of Oxime and Semicarbazone Formation
JENCKS, W. P. (1968) · Organic Functional Group Analysis · doi:10.1016/b978-0-08-203484-1.50017-x · Cited by 306
Mechanisms of L-Cysteine Neurotoxicity
Janáky, R., Varga, V., Hermann, A., Saransaari, P., & Oja, S. S. (2000) · Neurochemical Research · doi:10.1023/a:1007616817499 · Cited by 291
Neural-Tube Defects and Derangement of Homocysteine Metabolism
(1991) · New England Journal of Medicine · doi:10.1056/nejm199101173240315 · Cited by 285
COMPOUNDS OF THIOL ACIDS WITH ALDEHYDES
Schubert, M. P. (1936) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)65226-7 · Cited by 257
Molecular basis of homocysteine toxicity in humans
Jakubowski, H. (2004) · Cellular and Molecular Life Sciences (CMLS) · doi:10.1007/s00018-003-3204-7 · Cited by 255
Winters, R. A., Zukowski, J., Ercal, N., Matthews, R. H., & Spitz, D. R. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1246 · Cited by 220
Tanaka, F., Mase, N., & Barbas III, C. F. (2004) · Chemical Communications · doi:10.1039/b405642f · Cited by 206
Direct Detection of Homocysteine
Wang, W., Escobedo, J. O., Lawrence, C. M., & Strongin, R. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0318838 · Cited by 198
Self-citationFully automated fluorescence assay for determining total homocysteine in plasma.
Refsum, H., Ueland, P. M., & Svardal, A. M. (1989) · Clinical Chemistry · doi:10.1093/clinchem/35.9.1921 · Cited by 196
Chen, S.-J., & Chang, H.-T. (2004) · Analytical Chemistry · doi:10.1021/ac049787s · Cited by 186
Chow, C., Chiu, B. K.-W., Lam, M. H., & Wong, W. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034891x · Cited by 138
Ivanov, A. R., Nazimov, I. V., & Baratova, L. A. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00947-4 · Cited by 131
Zhao, R., Lind, J., Merényi, G., & Eriksen, T. E. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00105a048 · Cited by 123
Homocysteine: is it a clinically important cardiovascular risk factor?
Lentz, S. R., & Haynes, W. G. (2004) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.71.9.729 · Cited by 105
Grierson, L., Hildenbrand, K., & Bothe, E. (1992) · International Journal of Radiation Biology · doi:10.1080/09553009214552111 · Cited by 77
Abedinzadeh, Z. (2001) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y00-085 · Cited by 74
Assay Methods for the Measurement of Total Homocyst(e)ine in Plasma
Ubbink, J. (2000) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2000-8468 · Cited by 73
High-performance liquid chromatographic method for measuring total plasma homocysteine levels
Fermo, I., Arcelloni, C., Mazzola, G., D’Angelo, A., & Paroni, R. C. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00405-8 · Cited by 66
Geoghegan, K. F., Hoth, L. R., Tan, D. H., Borzilleri, K. A., Withka, J. M., & Boyd, J. G. (2002) · Journal of Proteome Research · doi:10.1021/pr025503d · Cited by 58
Specific Labeling of Polypeptides at Amino-Terminal Cysteine Residues Using Cy5-benzyl Thioester
Schuler, B., & Pannell, L. K. (2002) · Bioconjugate Chemistry · doi:10.1021/bc025509t · Cited by 50
REACTIONS OF SEMIMERCAPTALS WITH AMINO COMPOUNDS
Schubert, M. (1937) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)74286-5 · Cited by 48
Comparison of Three Different Plasma Homocysteine Assays with Gas Chromatography–Mass Spectrometry
Ubbink, J., Delport, R., Riezler, R., & Vermaak, W. J. H. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.5.670 · Cited by 46
Homocysteine and Folate in Pregnancy
Ueland, P. M., & Vollset, S. E. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035709 · Cited by 44
Homocysteine in Health and Disease
Brenton, D. P. (2002) · Human Genetics · doi:10.1007/s00439-002-0693-7 · Cited by 42
Krokhin, O. V., Ens, W., & Standing, K. G. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1236 · Cited by 41
Evaluation of the AxSYM Homocysteine Assay and Comparison with the IMx Homocysteine Assay
Pernet, P., Lasnier, E., & Vaubourdolle, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.9.1440 · Cited by 36
Postcolumn HPLC Detection of Mono- and Oligosaccharides with a Chemosensor
Kim, K., Escobedo, J. O., Luce, N. N. S., Rusin, O., Wong, D., & Strongin, R. M. (2003) · Organic Letters · doi:10.1021/ol035978q · Cited by 30
Self-citation[Plasma homocysteine assay in the exploration of thrombosis in young subjects].
Bienvenu, T., Ankri, A., Chadefaux, B., & Kamoun, P. (1991) · PubMed · Cited by 27
Chow, C., Lam, M. H., Sui, H., & Wong, W. (2005) · Dalton Transactions · doi:10.1039/b410974k · Cited by 24
Cited by
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Niu, L.-Y., Guan, Y.-S., Chen, Y.-Z., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309079f · Cited by 901
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Self-citation
Metadata
- Authors
- Wang, W., Rusin, O., Xu, X., Kim, K. K., Escobedo, J. O., Fakayode, S. O., Fletcher, K. A., Lowry, M., Schowalter, C. M., Lawrence, C. M., Fronczek, F. R., Warner, I. M., & Strongin, R. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-21
- Volume
- 127
- Issue
- 45
- Pages
- 15949-15958
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1988887549
- Cited by
- 593
- References
- 42
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.