The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
FRET-Based Mito-Specific Fluorescent Probe for Ratiometric Detection and Imaging of Endogenous Peroxynitrite: Dyad of Cy3 and Cy5
Abstract
Peroxynitrite (OONO(-)) is profoundly implicated in health and disease. The physiological and pathological outcome of OONO(-) is related to its local concentration, and hence, a reliable OONO(-) assay is highly desired. We have developed a FRET-based small-molecule fluorescent probe (PNCy3Cy5), harnessing the differential reactivity of Cy3 and Cy5 toward OONO(-) by fine-tuning. It exhibits high detection sensitivity and yields a ratiometric fluorescent signal. We have exemplified that it can be applied in semiquantitative determination of OONO(-) in living cells. Notably, it specifically localizes in mitochondria, where endogenous OONO(-) is predominantly generated. Thus, PNCy3Cy5 is a promising molecular tool for peroxynitrite biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beckman, J. S., Beckman, T. W., Chen, J., Marshall, P. A., & Freeman, B. A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.4.1620 · Cited by 7,029
Nitric Oxide and Peroxynitrite in Health and Disease
Pacher, P., Beckman, J. S., & Liaudet, L. (2007) · Physiological Reviews · doi:10.1152/physrev.00029.2006 · Cited by 6,390
Structure, mechanism and regulation of peroxiredoxins
Wood, Z. A., Schröder, E., Robin Harris, J., & Poole, L. B. (2003) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(02)00003-8 · Cited by 2,544
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
The reaction of NO with superoxide
Huie, R. E., & Padmaja, S. (1993) · Free Radical Research Communications · doi:10.3109/10715769309145868 · Cited by 2,121
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Peroxynitrite, a cloaked oxidant formed by nitric oxide and superoxide
Koppenol, W. H., Moreno, J. J., Pryor, W. A., Ischiropoulos, H., & Beckman, J. S. (1992) · Chemical Research in Toxicology · doi:10.1021/tx00030a017 · Cited by 1,338
FRET-Based Small-Molecule Fluorescent Probes: Rational Design and Bioimaging Applications
Yuan, L., Lin, W., Zheng, K., & Zhu, S. (2013) · Accounts of Chemical Research · doi:10.1021/ar300273v · Cited by 1,021
Oxidative Damage and Tyrosine Nitration from Peroxynitrite
Beckman, J. S. (1996) · Chemical Research in Toxicology · doi:10.1021/tx9501445 · Cited by 992
Monitoring of relative mitochondrial membrane potential in living cells by fluorescence microscopy.
Johnson, L. V., Walsh, M. L., Bockus, B. J., & Chen, L. B. (1981) · The Journal of cell biology · doi:10.1083/jcb.88.3.526 · Cited by 913
Cited by
Fluorescent chemosensors: the past, present and future
Wu, D., Sedgwick, A. C., Gunnlaugsson, T., Akkaya, E. U., Yoon, J., & James, T. D. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00240h · Cited by 2,002
Zielonka, J., Joseph, J., Sikora, A., Hardy, M., Ouari, O., Vasquez-Vivar, J., Cheng, G., Lopez, M., & Kalyanaraman, B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00042 · Cited by 1,683
Förster resonance energy transfer (FRET)-based small-molecule sensors and imaging agents
Wu, L., Huang, C., Emery, B. P., Sedgwick, A. C., Bull, S. D., He, X.-P., Tian, H., Yoon, J., Sessler, J. L., & James, T. D. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00318e · Cited by 1,026
Molecular Engineering of NIR‐II Fluorophores for Improved Biomedical Detection
Lei, Z., & Zhang, F. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202007040 · Cited by 683
Fluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Fluorescent small organic probes for biosensing
Tian, X., Murfin, L. C., Wu, L., Lewis, S. E., & James, T. D. (2021) · Chemical Science · doi:10.1039/d0sc06928k · Cited by 520
Li, H., Kim, H., Xu, F., Han, J., Yao, Q., Wang, J., Pu, K., Peng, X., & Yoon, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00307k · Cited by 509
Cheng, D., Pan, Y., Wang, L., Zeng, Z., Yuan, L., Zhang, X., & Chang, Y.-T. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b10508 · Cited by 500
Zhou, R., Zhou, R., Prasad, K., Fang, Z., Speight, R., Bazaka, K., & Ostrikov, K. (. (2018) · Green Chemistry · doi:10.1039/c8gc02800a · Cited by 497
Jiao, X., Li, Y., Niu, J., Xie, X., Wang, X., & Tang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04234 · Cited by 484
Wu, D., Chen, L., Xu, Q., Chen, X., & Yoon, J. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00307 · Cited by 387
Lei, Z., Sun, C., Pei, P., Wang, S., Li, D., Zhang, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201904182 · Cited by 362
Zeng, S., Liu, X., Kafuti, Y. S., Kim, H., Wang, J., Peng, X., Li, H., & Yoon, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00799a · Cited by 341
Near infrared fluorescent probes for detecting and imaging active small molecules
Ding, C., & Ren, T. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2023.215080 · Cited by 247
FRET Based Biosensor: Principle Applications Recent Advances and Challenges
Verma, A. K., Noumani, A., Yadav, A. K., & Solanki, P. R. (2023) · Diagnostics · doi:10.3390/diagnostics13081375 · Cited by 202
A general approach to the design of high-performance near-infrared (NIR) D-π-A type fluorescent dyes
Luo, X., Li, J., Zhao, J., Gu, L., Qian, X., & Yang, Y. (2019) · Chinese Chemical Letters · doi:10.1016/j.cclet.2019.03.012 · Cited by 119
Self-citation
Metadata
- Authors
- Jia, X., Chen, Q., Yang, Y., Tang, Y., Wang, R., Xu, Y., Zhu, W., & Qian, X.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-08-22
- Volume
- 138
- Issue
- 34
- Pages
- 10778-10781
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2514279849
- Cited by
- 341
- References
- 36
- FWCI
- 21.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.